Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    120- 240 V TRANSFORMER Search Results

    120- 240 V TRANSFORMER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TUSS4440TRTJT
    Texas Instruments Transformer drive ultrasonic sensor IC with logarithmic amplifier Visit Texas Instruments Buy
    PUCC12051DVEQ1
    Texas Instruments Automotive, 500-mW, 5-kVrms isolated DC/DC module with integrated transformer Visit Texas Instruments Buy
    UCC25800AQDGNQ1
    Texas Instruments Ultra-low EMI transformer driver for isolated bias supplies 8-HVSSOP -40 to 125 Visit Texas Instruments
    ISO1176TDW
    Texas Instruments Isolated ProfiBus Transceiver with integrated transformer driver 16-SOIC -40 to 85 Visit Texas Instruments Buy
    ISO3086TDWR
    Texas Instruments Isolated 485 Transceiver with integrated transformer driver 16-SOIC -40 to 85 Visit Texas Instruments Buy

    120- 240 V TRANSFORMER Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    77206

    Abstract: 77208C 77205C 77209C 77-20-2C 77205
    Contextual Info: 772 Series POWER ELECTRONICS DIVISION Pulse Transformers SELECTION GUIDE Primary Inductance Min. 1.0 1.0 1.0 1.0 4.0 4.0 4.0 Primary Et Constant (Min.) 120 120 120 120 240 240 n Up to 482 V s Et rating Leakage Inductance (Max.) 2.0 3.0 3.5 3.5 5.0 n PCB mounting


    Original
    4000Vrms 77206 77208C 77205C 77209C 77-20-2C 77205 PDF

    K3009U

    Contextual Info: mm HAMMOND /U4NUE4CTURING,. i l l w Transformers COPPER WOUND — SINGLE PHASE Pri V Sec V 240 x 480 120/240 kVA Mfr No. Wiring Dlag. Mfr. No. Wiring Dlag. Mfr. No. Wiring Diag. 3 5 7.5 10 15t 251 37.5 50 75 100 150 167 250 333 Q003LECF Q005LECF Q007LECF Q010LECF


    OCR Scan
    Q003LECF Q005LECF Q007LECF Q010LECF F015LEC F025LEC F037LEC F050LEC F075LEC F100LEC K3009U PDF

    TA-83215

    Abstract: TA-83224 TA-83315 TA-83213 PL-112705 TA-83210 TA-83222 TA-83219 PL-11270 PL-112700
    Contextual Info: SECTION V INDUSTRIAL CONTROL TRANSFORMERS GROUP J 240 X 480 PRIMARY VOLTS — 120/240 SECONDARY VOLTS — 1Ø, 60 Hz CATALOG NO. VA RATING OUTPUT AMPS TA-83210 50 0.42 TA-83212 100 0.83 TA-83213 150 1.25 TA-83215 250 2.08 TA-83218 500 4.17 TA-83219 750 6.25


    Original
    TA-83210 TA-83212 TA-83213 TA-83215 TA-83218 TA-83219 TA-83220 TA-83221 TA-83222 TA-83223 TA-83215 TA-83224 TA-83315 TA-83213 PL-112705 TA-83210 TA-83222 TA-83219 PL-11270 PL-112700 PDF

    220 ac INVERTER without transformer

    Abstract: 220v to 110v INVERTER without transformer 220v AC to 110v AC transformer circuit diagram an AND8005 220v AC to 110v AC transformer circuit diagram high voltage transformer 100 kW 1N5349 2N2222 220 110 transformer 2N2222 circuit
    Contextual Info: AND8005/D Automatic AC Line Voltage Selector http://onsemi.com APPLICATION NOTE INTRODUCTION In some cases, appliances and equipment are able to operate when supplied by two different levels of AC line voltage to their main terminals 120 V or 240 V . This is


    Original
    AND8005/D 220 ac INVERTER without transformer 220v to 110v INVERTER without transformer 220v AC to 110v AC transformer circuit diagram an AND8005 220v AC to 110v AC transformer circuit diagram high voltage transformer 100 kW 1N5349 2N2222 220 110 transformer 2N2222 circuit PDF

    1000 kVA transformer

    Contextual Info: -1*-* f [ *; c;, !l Ians @ - :. ,„2M„ INPUT VOLTAGE 120 X 240: OUTPUT VOLTAGE 12/24 — 60 Hz Catalog Number Insulating Transformer Rating Secondary Maximum Current Output 12V 24 V Approximate Dimensions In Inches Height Width Depth Approximate Net Weight


    OCR Scan
    T-1-81047 T-1-81048 T-1-81049 T-1-81050 T-1-81051 f-1-81052 T-1-11683 T-1-11684 T-1-13073 T-1-13074 1000 kVA transformer PDF

    c3194

    Abstract: transistor c3194 5B35-04 5B35 5B35-01 5B35-02 5B35-03 5B35-05 5B35-C-01 5B35-C-02
    Contextual Info: a FEATURES Accepts a Variety of RTD Types 100 ⍀ Platinum, 10 ⍀ Copper, 120 ⍀ Nickel Linearizes RTD Signal 1500 V rms Input/Output and Input/Power Isolation 250 V rms Output/Power Isolation 240 V rms Field Wiring Protection 4-Wire Lead Resistance Compensation


    Original
    01C/C 5B35-04 c3194 transistor c3194 5B35 5B35-01 5B35-02 5B35-03 5B35-05 5B35-C-01 5B35-C-02 PDF

    Contextual Info: NiiSB • r t n i H H Wh Specifications 120 X 240 PRIMARY VOLTS — 12/24 SECONDARY VOLTS — 60 Hz CATALOG NUMBER INSULATING TRANSFORMER RATING T-1-81047 T-1-81048 T-1-81049 SECONDARY MAXIMUM Current Output APPROX. DIMENSIONS Inches Cm. 12 V 24 V HEIGHT


    OCR Scan
    T-1-81047 T-1-81048 T-1-81049 T-1-81050 T-1-81051 T-1-81052 T-1-13077 T-2-13078 T-2-13079 PDF

    PHE-7351-15

    Contextual Info: INDUSTRIAL PH INSTRUMENTATION & ELECTRONICS Mini Panel-Mount pH Controller Model PHCN-201 $ 120 Basic Unit ߜ ߜ ߜ ߜ User-Selectable Acid or Alkaline Relay Simple One-Point Calibration Reduced Size to Facilitate Installation Choose from 100-240 V or Low Voltage


    Original
    PHCN-201 PHCN-201 PHCN-201, PHE-7351-15, PHE-7351-15 PDF

    32901A

    Abstract: 32212a 32048A 32205A 32012B 32012a 32005E 32024D 32005B Calex
    Contextual Info: 32000 Series Open Frame AC/DC Regulated Linear Power Supplies General Specifications A.C. Input D.C. Output Line Regulation Load Regulation Output Ripple 100/120/220/240 V AC +10%, -12%, 47 to 60 Hz See Voltage/Current Rating Chart. Adjustment range ±5% minimum.


    Original
    2901A 32901B 32901A 32212a 32048A 32205A 32012B 32012a 32005E 32024D 32005B Calex PDF

    Diode LT 404

    Contextual Info: s e M IK R D n SKiiP 312 GDL 120 - 404 WT E/U Absolute Maximum Ratings Symbol | Conditions Values Units 1200 - 5 5 . . . + 150 V V A A °C 3 0 0 0 5) V 240 A A A kA2s 11 IGBT & Invcsrse Diode Vces Operating DC link voltage Vc c 10) Theatsink — 2 5 °C


    OCR Scan
    613bb71 QQ05Q01 ai3bb71 0GQ50G3 00G5D04 Diode LT 404 PDF

    SMD diode sg 46

    Abstract: 1n4148 zener diode SG 46 a DIODE SMD RK73H1JT1001F WECO filter C3216X7R2J223KT0L0U Y2 diode SG 21 DIODE SMD cl31b zener diode 15v
    Contextual Info: PRELIMINARY PFM V•I Chip PFM Power Factor Module • • • • • • • • • F3D480T20A DC+ Input: rectified 120/240 Vac sinusoidal Output: 48 Vdc programmable Output power: Up to 200 W 4,242 Vdc reinforced insulation 90% efficiency 375 W/in3 power density


    Original
    F3D480T20A SMD diode sg 46 1n4148 zener diode SG 46 a DIODE SMD RK73H1JT1001F WECO filter C3216X7R2J223KT0L0U Y2 diode SG 21 DIODE SMD cl31b zener diode 15v PDF

    PFC buck converter design

    Abstract: 1N4148 SMD PACKAGE 3 phase bridge fully controlled rectifier 1206 smd 100 ohm resistor sc 6200 Ferrite Bead TDK SMD diode sg 46 SG 21 DIODE SMD 1n4148 zener diode buck converter vout 100v
    Contextual Info: PRELIMINARY PFM V•I Chip PFM Power Factor Module • • • • • • • • • F3D480T20A DC+ Input: rectified 120/240 Vac sinusoidal Output: 48 Vdc programmable Output power: Up to 200 W 4,242 Vdc reinforced insulation 90% efficiency 375 W/in3 power density


    Original
    F3D480T20A PFC buck converter design 1N4148 SMD PACKAGE 3 phase bridge fully controlled rectifier 1206 smd 100 ohm resistor sc 6200 Ferrite Bead TDK SMD diode sg 46 SG 21 DIODE SMD 1n4148 zener diode buck converter vout 100v PDF

    convert select 120

    Abstract: 1740-6M1 1240-6M1 chloride systems 48v charger LWN2660-6 24V battery charger 12406M1 7213 BATTERY CHARGER ACID
    Contextual Info: DIN-Rail Mountable AC-DC Converters 125, 250 Watt AC-DC Converters W Series Convert Select 120, 240 Rugged 35 mm DIN-rail snap-fit design Class I equipment Single or double outputs for 24 or 48 V DC loads • Universal AC-input with single stage conversion


    Original
    22/EN convert select 120 1740-6M1 1240-6M1 chloride systems 48v charger LWN2660-6 24V battery charger 12406M1 7213 BATTERY CHARGER ACID PDF

    convert select 120

    Abstract: 1740-6M1 convert select 240 Battery Chargers planar Transformer circuit
    Contextual Info: W Series Extended Data Sheet 125, 250 Watt AC-DC DC-DC - Convert Select 120, 240 Rugged 35 mm DIN-rail snap-fit design Class I equipment Single or double outputs for 24 or 48 V DC loads • Universal AC-input with single stage conversion AC to DC with PFC, DC input 90 to 275 V


    Original
    22/EN 89/336/EEC convert select 120 1740-6M1 convert select 240 Battery Chargers planar Transformer circuit PDF

    Contextual Info: ANALOG DEVICES FEATURES Accepts a V ariety of RTD Types 100 i l Platinum , 10 i l Copper, 120 i l Nickel Linearizes RTD Signal 1500 V rms In p u t/O u tp u t and In p u t/P o w er Isolation 250 V rms O u tp u t/P o w e r Isolation 240 V rms Field W iring Protection


    OCR Scan
    5B35-01 5B35-02 5B35-03 5B35-04 5B35-05 5B35-C-01 5B35-C-02 5B35-N-01 PDF

    FS-2-2000

    Abstract: FS115 PL-79905 PL-79906 by 550-208 PL-79908 FS-2-1000 FS1500 FS-2-250 FS250
    Contextual Info: SECTION V FINGER/GUARD INDUSTRIAL CONTROL TRANSFORMERS SELECTION CHARTS GROUP A 120 X 240 PRIMARY VOLTS — 24 SECONDARY VOLTS — 50/60 Hz CATALOG NO. FS-1-50 FS-1-75 FS-1-100 FS-1-150 FS-1-250 FS-1-350 FS-1-500 FS-1-750 FS-1-1000 VA RATING 50 75 100 150


    Original
    FS-1-50 FS-1-75 FS-1-100 FS-1-150 FS-1-250 FS-1-350 FS-1-500 FS-1-750 FS-1-1000 PL-79905 FS-2-2000 FS115 PL-79905 PL-79906 by 550-208 PL-79908 FS-2-1000 FS1500 FS-2-250 FS250 PDF

    5B35

    Abstract: 5B35-01 5B35-02 5B35-03 5B35-04 5B35-05 5B35-C-01 5B35-C-02 5B35-N-01
    Contextual Info: ANALOG DEVICES FEATURES Accepts a V a rie ty o f RTD Types 100 i l P latin u m , 10 i l C o p per, 120 i l Nickel Lin earizes RTD Sign al 1500 V rm s In p u t/O u tp u t and In p u t/P o w e r Iso latio n 250 V rm s O u tp u t/P o w e r Iso latio n 240 V rm s Field W irin g P ro tectio n


    OCR Scan
    5B35-C-CUSTOM. 5B35-N-CUSTOM. 5B35 5B35-01 5B35-02 5B35-03 5B35-04 5B35-05 5B35-C-01 5B35-C-02 5B35-N-01 PDF

    single phase transformer

    Abstract: M6020-9Y m60205 M6020-18PS M6020-2S M6020-27Y m601 M6020E-12Y M6020-8PS 6020CT-2S
    Contextual Info: Variable Transformers Series 6000 l 35.0 to 315.0 Amperes 5000/6000 Series Manual Single, Uncased Two Ganged 17.06” [433.3] 13.56” [344.4] 15.12” [384.2] A B C Three Ganged 23.12” [587.4] 19.62” [498.3] 21.19” [538.2] Manual Two and Three-Ganged, Uncased


    Original
    PDF

    M50119P

    Abstract: M50115P m50115 M50117P M5011 5011-6Y 5021E-6P M5021-9Y 5021CT M50118P
    Contextual Info: Variable Transformers Series 5000 l 28.0 to 252.0 Amperes 5000 Series The 5011/5021 Series Variable transformers are designed to control large KVA requirements. The 5011 operates on 120 volts and is rated for constant current of 50 amperes. The 5021 operates on 240 volts and constant current of 28 amperes. The


    Original
    27-Ganged, 18-Ganged 60M5021-27Y M50119P M50115P m50115 M50117P M5011 5011-6Y 5021E-6P M5021-9Y 5021CT M50118P PDF

    1156D-1256D

    Abstract: powerstat 1156D powerstat 1256DU-3Y powerstat 116 T5587 1256D-2P 1256DU powerstat t5587 1156DT-3Y
    Contextual Info: 1156D-1256D series POWERSTAT Variable Transformers of the 1156D-1256D Series are available in single and three phase, manually operated and motor-driven assemblies. The 1156D Series operates from 120 volt lines and the 1256D Series from 240 volt lines. The rated


    OCR Scan
    1156D-1256D 1156D 1256D allowa837 18-GANG powerstat 1156D powerstat 1256DU-3Y powerstat 116 T5587 1256D-2P 1256DU powerstat t5587 1156DT-3Y PDF

    Contextual Info: DRY-TYPE DISTRIBUTION TRANSFORMERS SECTIO N 1 Do You Have a Non-Standard Three Phase Voltage Application?_ M any non-standard v o lta y r c u n v c lii i problem s can lx* solved by u h n y standard off-the-shelf sinyle phase transtnm uT'The follow ing is a list of such volt aye


    OCR Scan
    208Y/120 416Y/240 Delta/120 PDF

    Class 130B transformer

    Abstract: 4600 transformer tyco transformer manufacturing process flow chart Class 130(B) transformer 4000-05E07K Part Numbering System transformer Tyco transformer 10va 9100 series relay 4000-78J15BB TRANSFORMER 20VA 24v
    Contextual Info: Catalog 1308242 Issued 3-03 SELECTOR GUIDE Transformers Click here for Alphanumeric Index PRODUCTS UNLIMITED PRODUCTS UNLIMITED PRODUCTS UNLIMITED PRODUCTS UNLIMITED PRODUCTS UNLIMITED 4000 4000 4000 4000 4000 Class II UL1585 Transformer Class II UL1585 Transformer


    Original
    UL1585 Class 130B transformer 4600 transformer tyco transformer manufacturing process flow chart Class 130(B) transformer 4000-05E07K Part Numbering System transformer Tyco transformer 10va 9100 series relay 4000-78J15BB TRANSFORMER 20VA 24v PDF

    transformer 24-0-24

    Contextual Info: 6 Buck–Boost Transformers Buck-Boost transformers are small, single phase, dry type distribution transformers designed and shipped as insulating/isolating transformers. They have a dual voltage primary and a dual voltage secondary. These transformers can be connected for a wide range of voltage combinations.


    Original
    PDF

    6v step down transformers

    Contextual Info: FETCO TYPE IPTL ECTRO TUCHNIK ISOLATION POWER TRANSFORMERS / STEP UP or STEP DOWN - - Features: • I Output Voltage: 1 04V, 11 OV, 1 20V, 208V, 220V, 230V, & 240V • Power: 250VA to 10 KVA • • • Dielectric Strength: 2500 VRMS Hipot 0C Insulation: Class “A’ insulation - 105


    Original
    250VA and208/220/240 6v step down transformers PDF