Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    133X558 Search Results

    133X558 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    1453599

    Abstract: 143X559 1433559 E62806 1000VCERating
    Text: Power Splicer/Stud Blocks 600 Volts AC/DC Up to 1000 Volts AC/DC + Specifications: • Multiple wire rating - refer to datasheets for details 1433559 1453599 • UL Recognized File No. XCFR2.E62806 • CSA Certified File No. LR19766 (does not apply to 133X559, 133X558, and 143X559)


    Original
    PDF E62806 LR19766 133X559, 133X558, 143X559) com/PDFs/1000VCERating 1453599 143X559 1433559 E62806 1000VCERating

    E62806

    Abstract: No abstract text available
    Text: Product Data Sheet 133X558 Replace “X” with 1, 2 or 3 for number of poles Power Splicer/Stud Block 310 Amps, 600 Volts AC/DC See tables below for wire ranges, flexible stranded and multiple wire approvals. Wire Range: Line side: (1) 350kcmil - #6 AWG


    Original
    PDF 133X558 350kcmil 350kcmil E62806

    E62806

    Abstract: M10x30
    Text: Product Data Sheet 133X558 CH Replace “X” with 1, 2 or 3 for number of poles Power Splicer/Stud Block 310 Amps, 600 Volts AC/DC See tables below for wire ranges, flexible stranded and multiple wire approvals. Wire Range: Line side: (1) 350kcmil - #6 AWG


    Original
    PDF 133X558 350kcmil thes259 350kcmil E62806 M10x30

    1332554

    Abstract: 1322122 1332555 1331552 1323572 1333598 1322570 1322572 1323970 1322580
    Text: Thermoplastic Power Blocks With Hinge Covers Attached CH Exclusive Features: 1 Largest variety of connectors offered on a mid-size footprint 2 Higher amperage available on a compact size molding 3 Hinge cover standard and attached, rated IP1 4 132 Series offers an integral DIN rail-mounting feature


    Original
    PDF 6193K/04-08/1000/TP/BH 1332554 1322122 1332555 1331552 1323572 1333598 1322570 1322572 1323970 1322580

    145X282

    Abstract: No abstract text available
    Text: Power Distribution Blocks with SCCR and Feeder Spacing Short-Circuit Current Ratings and Feeder Spacing SCCR Information: The requirements of the National Electric Code NEC and UL508A now require many electrical panels to carry a Short Circuit Current Rating


    Original
    PDF UL508A 350MCM-6 145X282

    msc 1697

    Abstract: 486A-486B nec 08f DLS FT 031 awg 1608 F60A1B Transistor NEC 05F 6J200A3B KULKA 9-85 1432126
    Text: ENGINEERING CATALOG March, 2008 What’s New: • Flexible Stranded Wire UL Rating Information • SCCR with Fuses or Circuit Breakers • Datasheets on www.marathonsp.com • • • • FUSE HOLDERS POWER BLOCKS TERMINAL BLOCKS CUSTOM PRODUCTS www.marathonsp.com


    Original
    PDF 6137K/SK/7500/3-08/DBH msc 1697 486A-486B nec 08f DLS FT 031 awg 1608 F60A1B Transistor NEC 05F 6J200A3B KULKA 9-85 1432126