Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    175 VA TRANSFORMER Search Results

    175 VA TRANSFORMER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    WB1040-SML Coilcraft Inc Transformer Visit Coilcraft Inc
    AS8426-A Coilcraft Inc Telecom Transformer Visit Coilcraft Inc Buy
    B0727-B Coilcraft Inc Telecom Transformer Visit Coilcraft Inc Buy
    AS8954-A Coilcraft Inc Telecom Transformer Visit Coilcraft Inc
    CR7984-CLD Coilcraft Inc Datacom Transformer Visit Coilcraft Inc

    175 VA TRANSFORMER Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    DST4-36B26

    Abstract: No abstract text available
    Text: LAMINATED Transformers pulseelectronics.com LT2012 4/12 PRODUCT OVERVIEW: LAMINATED TRANSFORMERS Pulse ofers power ratings from 1.1 VA to 175 VA, open frame transformers, with a wide variety of domestic and international agency approvals. Pulse is truly


    Original
    PDF LT2012 DST4-36B26

    Untitled

    Abstract: No abstract text available
    Text: PA RT VDE Quick-Connect Transformers VA NU MB ER Series 6494 – 6498 25 25 25 25 25 25 25 25 43 43 43 43 43 43 43 43 80 80 80 80 80 80 80 80 130 130 130 130 130 130 130 130 175 175 175 175 175 175 175 175 6494-010 6494-012 6494-016 6494-020 6494-024 6494-028


    Original
    PDF

    LT 5239 H

    Abstract: LT 5239
    Text: PA RT VDE Quick-Connect Transformers VA NU MB ER Series 6494 – 6498 25 25 25 25 25 25 25 25 43 43 43 43 43 43 43 43 80 80 80 80 80 80 80 80 130 130 130 130 130 130 130 130 175 175 175 175 175 175 175 175 6494-010 6494-012 6494-016 6494-020 6494-024 6494-028


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: PA RT VDE Quick-Connect Transformers VA NU MB ER Series 6494 – 6498 25 25 25 25 25 25 25 25 43 43 43 43 43 43 43 43 80 80 80 80 80 80 80 80 130 130 130 130 130 130 130 130 175 175 175 175 175 175 175 175 6494-010 6494-012 6494-016 6494-020 6494-024 6494-028


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: PA RT VDE Quick-Connect Transformers VA NU MB ER Series 6494 – 6498 25 25 25 25 25 25 25 25 43 43 43 43 43 43 43 43 80 80 80 80 80 80 80 80 130 130 130 130 130 130 130 130 175 175 175 175 175 175 175 175 6494-010 6494-012 6494-016 6494-020 6494-024 6494-028


    Original
    PDF

    185E28

    Abstract: Transformer 115V 12.6v Transformer 115V 24V 185G230 185C12 185C16 185D10 185D12 185E10 185F10
    Text: Power Global Use-Terminal Connection 185 Series 25 & 43 VA Mount (Figure A) 80, 130 & 175 VA Mount (Figure B) GLOBAL USE - CHASSIS MOUNT POWER TRANSFORMERS Transformer Schematic • Dual primary 115/230 VAC • 50/60 Hz. operation • Dual secondaries for series or parallel connections


    Original
    PDF

    61558-2-6

    Abstract: 12-0-12V 200VA 24-0-24V EN 61558-2-4, VA 200 300VA 55-0-55V 24-0-24 50413
    Text: RS RANGE OF SAFETY/ISOLATING TRANSFORMERS C A B D Dimensions mm VA A 50 84 100 84 150 108 200 108 300 120 500 120 1000 150 B 91 91 110 110 130 130 155 C 84 97 90 114 143 143 175 F Fixings (mm) D E 64 64 64 72 84 72 84 92 90 106 90 106 122 132 E F 4.5 4.5


    Original
    PDF 230/400V 5-0-230-400V/12-0-12V 150VA 5-0-230-400V/55-0-55V 200VA 5-0-230-400V/24-0-24V 61558-2-6 12-0-12V 200VA 24-0-24V EN 61558-2-4, VA 200 300VA 55-0-55V 24-0-24 50413

    VPS56-2300

    Abstract: VPS24-5400 VPS10-13000 VPS12 VPS-28 VPS16-1600 VPS12-10300 VPS230-760 VPS28-4600 vps36-3600
    Text: Class B C h a s s i s M o u n t : Q u i c k - C o n n e c t W o r l d S e r i e s : D e s c r i p t i o n Triad chassis mount World Series transformers are designed to meet U.S. and International standards including CSA, IEC, VDE and UL requirements. The transformers consist of a dual bobbin design positioned inside an


    Original
    PDF

    266L24

    Abstract: E50394 e50394 transformer 185E24 LR3902 266N12 266K18 ct 2300 transformer primary 115 secondary 12.6 185E12
    Text: 1012-2012:QuarkCatalogTempNew 8/28/12 1:30 PM Page 1012 TRANSFORMERS ENCLOSURES INTERCONNECT TEST & MEASUREMENT 11 Transformers Global Use — AC Power Transformers ᭤ ᭤ ᭤ ᭤ ᭤ ᭤ ᭤ ᭤ ᭤ ᭤ ᭤ ᭤ W Dual Primary 115/230 VAC 50/60 Hz Operation


    Original
    PDF 7018put LR3902) E50394) PHC50LGA 266L24 E50394 e50394 transformer 185E24 LR3902 266N12 266K18 ct 2300 transformer primary 115 secondary 12.6 185E12

    a41-25-24

    Abstract: SM 63A a41-175-24 A41-43-36 signal transformer a41-80-24 A41-130-24 lr51265
    Text: All-4-One International Transformers Chassis Mount SM International Standards at Lower Cost and Better Performance CV Signal’s A41 transformers provide the high isolation, creepage and clearance necessary to comply with international safety standards.


    Original
    PDF 4000VRMS 24hrs) a41-25-24 SM 63A a41-175-24 A41-43-36 signal transformer a41-80-24 A41-130-24 lr51265

    signal transformer a41-80-24

    Abstract: 12v 6A transformer A41-130-24 ul 506 class 130 A41-130-10 signal transformer a41-130-20 A41-80-10 A41 L a41-175-24 A41-175-10
    Text: All-4-One International Transformers Chassis Mount International Standards at Lower Cost and Better Performance SM Designed to provide the high isolation, creepage and clearance necessary to comply with international safety standards. General Specifications


    Original
    PDF 94-V0 E66312 E63829 signal transformer a41-80-24 12v 6A transformer A41-130-24 ul 506 class 130 A41-130-10 signal transformer a41-130-20 A41-80-10 A41 L a41-175-24 A41-175-10

    Transformer a41-175-16

    Abstract: 20VCT signal transformer SM 63A E63829 lr51265 chassis a41 A41-25-24 A41-130-10 A41-80-24
    Text: All-4-One International Transformers Chassis Mount International Standards at Lower Cost and Better Performance SM Designed to provide the high isolation, creepage and clearance necessary to comply with international safety standards. General Specifications


    Original
    PDF 94-V0 E66312 E63829) Transformer a41-175-16 20VCT signal transformer SM 63A E63829 lr51265 chassis a41 A41-25-24 A41-130-10 A41-80-24

    signal transformer a41-80-24

    Abstract: A41-130-24 a41-25-24 230V Transformer specification a41-175-16 Transformer a41-175-16 A41-80-24 a41-175-24 A41-80-36 A41-43-12 a41-43-36
    Text: All-4-One International Transformers Chassis Mount International Standards at Lower Cost and Better Performance SM Designed to provide the high isolation, creepage and clearance necessary to comply with international safety standards. General Specifications


    Original
    PDF 94-V0 E66312 E63829 signal transformer a41-80-24 A41-130-24 a41-25-24 230V Transformer specification a41-175-16 Transformer a41-175-16 A41-80-24 a41-175-24 A41-80-36 A41-43-12 a41-43-36

    A41-130-16L

    Abstract: No abstract text available
    Text: All-4-One International Transformers Chassis Mount with Lead Wires SM International Standards at Lower Cost and Better Performance Designed to provide the high isolation, creepage and clearance necessary to comply with international safety standards. General Specifications


    Original
    PDF 94-V0 E66312 E63829 A41-130-16L

    4320L

    Abstract: 18AWG UL1015 hook up wire 2528l SM 63A vw 9a engines A41-25-24 transistor a41 8010L 2510L
    Text: All-4-One International Transformers Chassis Mount with Lead Wires International Standards at Lower Cost and Better Performance SM Designed to provide the high isolation, creepage and clearance necessary to comply with international safety standards. General Specifications


    Original
    PDF 94-V0 E66312 E63829 4320L 18AWG UL1015 hook up wire 2528l SM 63A vw 9a engines A41-25-24 transistor a41 8010L 2510L

    VPS24-5400

    Abstract: VPS-36-3600 VPS20-4000 VPS12-6300 VPS10-13000 VPS10-17500 VPS10-2500 VPS10-4300 VPS10-8000 VPS-12-6300
    Text: Untitled Document Page 1 of 2 CHASSIS MOUNT - WORLD SERIES Description: TRIAD chassis mount World Series transformers from Triad Magnetics are designed to meet U.S. and international standards including CSA, IEC, VDE and UL requirements. The transformers consist of a dual bobbin design


    Original
    PDF 175VA, are/16 VPS24-5400 VPS-36-3600 VPS20-4000 VPS12-6300 VPS10-13000 VPS10-17500 VPS10-2500 VPS10-4300 VPS10-8000 VPS-12-6300

    E173993

    Abstract: TGC25-12 white-rodgers TGC130-10 TGC130-12 TGC175-10 TGC175-12 TGC25-10 TGC25-16 TGC43-10
    Text: T R A N S G L O B A L I N T E R N A T I O N A L T R A N S F O R M E R S TransGlobal Chassis Mount Transformers TransGlobal Chassis Mount VA ≥ 80 VA TransGlobal® Chassis Mount (VA ≤ 43 VA) Style NV with lugs Style S with lugs Designed for single input and single output use only,


    Original
    PDF TGC25-10 TGC43-10 TGC80-10 TGC130-10 TGC175-10 E173993) EN60950 EN60742 TGC25, E173993 TGC25-12 white-rodgers TGC130-12 TGC175-12 TGC25-10 TGC25-16 TGC43-10

    RL-2260

    Abstract: RL-2260-25-10 HI-POT B-8
    Text: SAFETY RL-2260 UL RECOGNIZED E132629 ALL IN ONE POWER TRANSFORMERS DESCRIPTION FEATURES & APPLICATIONS • Linear Transformer • • • • ENVIRONMENTAL DATA • • Storage temperature range: -55°C to +130°C Operating temperature range: -40°C to +130°C


    Original
    PDF RL-2260 E132629 RL-2260 RL-2260-25-10 HI-POT B-8

    Untitled

    Abstract: No abstract text available
    Text: Series A41 International Power Transformers International High Power Transformers These transformers are built on dual bobbins with insulating shrouds to provide 4000V RMS isolation between primary and secondary. Non-concentric construction reduces primary-to-secondary


    Original
    PDF E73539

    100 VA 230v 50 Hz CENTER TAP transformer

    Abstract: 230v 50 Hz CENTER TAP transformer VPS-24-3300 VPP-36-1560 VPS16-1600 VPS-16-1600 VPS-16-2700 hi-pot 0830
    Text: 1031-2012:QuarkCatalogTempNew 8/28/12 2:24 PM Page 1031 11 Power Transformers — World Series RoHS D B A Secondary H Stock No. Mfr.’s Type Fig. VA Size Series CT* Volts C 115/230V 50/60 Hz MW W Amps Volts Amps H W D 213/16 21/2 115/16 25/16 213/16 31/8


    Original
    PDF 115/230V 100 VA 230v 50 Hz CENTER TAP transformer 230v 50 Hz CENTER TAP transformer VPS-24-3300 VPP-36-1560 VPS16-1600 VPS-16-1600 VPS-16-2700 hi-pot 0830

    Untitled

    Abstract: No abstract text available
    Text: All-4-One International Transformers Chassis Mount with Lead Wires International Standards at Lower Cost and Better Performance SM Designed to provide the high isolation, creepage and clearance necessary to comply with international safety standards. General Specifications


    Original
    PDF 94-V0 E66312 E63829 VDE30L 18AWG A41-130-230L A41-175-230L UL1015, 18AWG

    VPS12-2000

    Abstract: VPS10-17500 VPS12-6300 VPS16-1600 VPS10-2500 VPS10-4300 VPS10-8000 VPS12-10300 VPS12-3400 VPS10-13000
    Text: Subcategory Static - Power Transformers - Chassis Mount - World Series Product Catalog CHASSIS MOUNT - WORLD SERIES Description: TRIAD chassis mount World Series transformers from Triad Magnetics are designed to meet U.S. and international standards including CSA, IEC, VDE and UL requirements.


    Original
    PDF

    A41-80-20

    Abstract: A41-25-24
    Text: AII-4-One International Transform ers Chassis M ount BUY DIRECT International Standards at Lower Cost and Better Performance Signal’s A41 transformers provide the high isolation, creepage and clearance necessary to comply with international safety standards.


    OCR Scan
    PDF 4000VRMS 24hrs) A41-80-20 A41-25-24

    HIGHWAY 09A

    Abstract: No abstract text available
    Text: Power Transformers .t o Recognized Component Underwriters Labs, Inc. INTERNATIONAL SERIES POWER TRANSFORMERS UL, VDE, IEC and C SA certified. In addition to being certified to VDE 0806, IEC 380, CSA 22.2 No. 66 and UL506, the EWC series of International Transformers is designed


    OCR Scan
    PDF UL506, 175VA, RT25A HIGHWAY 09A