Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    2 KV TERMINAL BLOCKS Search Results

    2 KV TERMINAL BLOCKS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    GCJ32DR7LV104KW01K
    Murata Manufacturing Co Ltd Soft Termination Chip Multilayer Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    GCJ55DR7LV474KW01K
    Murata Manufacturing Co Ltd Soft Termination Chip Multilayer Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    GRJ55DR7LV474KW01K
    Murata Manufacturing Co Ltd Chip Multilayer Ceramic Capacitors with Soft Termination for General Purpose Visit Murata Manufacturing Co Ltd
    GCJ31BR7LV153KW01L
    Murata Manufacturing Co Ltd Soft Termination Chip Multilayer Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    GCJ32QR7LV683KW01L
    Murata Manufacturing Co Ltd Soft Termination Chip Multilayer Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd

    2 KV TERMINAL BLOCKS Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    4pin din female plug

    Contextual Info: 2 X-COM-SYSTEM 16 4-Pin Receptacle Terminal Blocks 500 V/6 kV/3 O 300/600 V, 10/5 A W 250 V/4 kV/3 O 300 V, 10 A a 24 A* Terminal block width 5 mm / 0.197 in * W«H§ O Terminal block width 5 mm / 0.197 in * 500 V = rated voltage 6 kV = rated surge voltage


    OCR Scan
    PDF

    Contextual Info: X-CO M -SYSTEM CAGE CLAMP* 1 -Conductor/1 -Pin and 2-Pin Disconnect Receptacle Terminal Blocks with 2 Jum per Positions 0.08 - 4 mm2 AWG 28 - 12 400 V/6 kV/3,16 A O 250 V/4 kV/3,16 A O Terminal block width 5 mm / 0.197 in i_ ^ 8 - 9 mm / 0.33 in O 400 V/6 kV/3,16 A O


    OCR Scan
    PDF

    Contextual Info: X-COM-SYSTEM 2-Conductor/ 2-Pin Receptacle Terminal Blocks 0.08 - 4 mm2 AWG 28 - 12 500 V/6 kV/3 O 300/600 V, 10/5 A TO 250 V/4 kV/3 O 300 V, 10 A « 24 A* Terminal block width 5 mm / 0.197 in i . ^ 3 8 - 9 mm / 0.33 in * to« ihs Item-No. Description 2-conductor/2-pin receptacle terminal block,


    OCR Scan
    PDF

    Contextual Info: 1 N-Conductor Disconnect Terminal Blocks / togfofc Power Distribution Disconnect Terminal Blocks 0.08 - 4 mm2 AWG 28 - 12 400 V/6 kV/3 32 A Terminal block width 6 mm / 0.236 in 9 - 10 mm / 0.37 in *© Item-No. Description Front-entry 0.2 - 6 m m 2 400 V/6 kV/3 ©


    OCR Scan
    PDF

    Contextual Info: CAGE CLftMfr CONNECTION 15 0.2 - 6 m m 2 800 V /8 kV/3 41 A AWG 24 - 10 Terminal block width 8 mm / 0.315 in 4-12 - 13 m m / 0 .4 9 in Colour Item-No. Pack.-unit pcs 2-conductor through terminal blocks 0.2 - 6 m m 2 800 V /8 kV/3 41 A AWG 24 -1 0 Terminal block width 8 mm / 0.315 in


    OCR Scan
    PDF

    Contextual Info: 8-Level Terminal Blocks for Matrix Patchboards 16 Front-entry 2 x 0 .0 8 - 1.5 m m 2 2 x A W G 28 - 1 6 2 5 0 V /4 kV/3 O 10 A 2 x 0 .0 8 - 1.5 m m 2 5 0 V /4 kV/3 O 10 A Terminal block width 7.62 mm / 0.3 in i_ la * 8 - 1 0 mm / 0.35 in Terminal block width 7.62 mm / 0.3 in


    OCR Scan
    31-pole, PDF

    Contextual Info: 4-Level Terminal Blocks for Matrix Patchboards 14 Front-entry 2 x 0 .0 8 -1 .5 m m 2 2xAW G 28 -1 6 250 V/4 kV/3 O 12 A 2x0.08 - 1 .5 m m 2 2xAW G 28 -1 6 250 V/4 kV/3 O 12 A Terminal block width 7.62 mm / 0.3 in * EBB 8 - 1 0 mm / 0.35 in Terminal block width 7.62 mm / 0.3 in


    OCR Scan
    31-pole, PDF

    Contextual Info: Protective conductor terminal blocks ZPE 4-2/3AN ZPE 6-2 W ZPE 6-2/3AN W ZPE 16-2/1AN ZEI 16-2/1AN W W Feed-in terminal Feed-in terminal W 6/61.5/46 10 8/68/50 10 8/68/50 10 12/65/51.5 18 13.8/61.5/51.5 18 – V/– A/4 mm2 800 V/8 kV/3 – V/– A/6 mm2 800 V/8 kV/3


    Original
    16-2/1AN PDF

    Contextual Info: 16 Front-entry 0.2 - 10 m m 2 800 V /8 kV/3 57 A 0.2 - 10 mm 2 800 V /8 kV/3 57 A 3 x 0.2 - 10 m m 2 1 x 6 - 35 mm2 800 V /8 kV/3; 125 A Terminal block width 10 mm / 0.394 in A _ _ _ _ _ _ b a a 12 - 13 mm / 0.49 in Terminal block width 10 mm / 0.394 in r


    OCR Scan
    PDF

    280-519

    Contextual Info: is Front-entry, Double and triple deck terminal blocks 0.08 - 2 . 5 m m 500 V /6 kV/3 20 A AW G 28 - 14 300 V, 15 A W 300/600 V, 20/5 A « Terminal block width 5 mm / 0.197 in 4_ p s a 8 —9 mm / 0.33 in 0.08 - 2 .5 m m 2 500 V /6 kV/3 20 A Terminal block width 5 mm / 0.197 in


    OCR Scan
    PDF

    Contextual Info: CAGE CLAMfit CONNECTION Front-entry, Disconnect terminal blocks 25 0.08 - 2.5 m m 2 AW G 28 - 14 300 V, 15 A TO 400 V/6 kV/3 10 A 300 V, 15 A Terminal block width 5 mm / 0.197 in i_Ma 8 - 9 mm / 0.33 in AWG 2 8 - 12* 0.08 - 2.5 m m 2 300 V 400 V/6 kV/3


    OCR Scan
    PDF

    Contextual Info: CAGE CLAMP* Through Terminal Blocks Front-entry 0.08 - 2 . 5 m m 2 8 0 0 V / 8 kV /3 O 20 A A W G 28 - 12 6 0 0 V, 2 0 A TO 6 0 0 V, 15 A € 0 .0 8 - 2 . 5 m m 2 8 0 0 V / 8 kV/3 20 A Terminal block w idth 5 m m / 0.197 in i_ taa Terminal block w idth 5 m m / 0.197 in


    OCR Scan
    PDF

    Contextual Info: Modular PCB Terminal Blocks and Terminal Strips, Pin Spacing 3.96/4 m m / 0.156 in; Series 235 S ide-entry Pin spacing 3.96/4 mm / 0.156 in Pin spacing 3.96/4 mm / 0.156 in ' AW G 2 0 -1 6 "s o l." 0.5 - 1.5 mm2"s"0 200 V /4 kV /3 , 10 A 400 V /4 kV /2 , 10 A


    OCR Scan
    PDF

    Contextual Info: Transverse and Longitudinal Disconnect Terminal Blocks, for Exam ple for Current Transformer Circuits ^ . cage c la m p " 0.2 - 6 m m 2 AWG 24 - 10 V, A % 500 V/6 kV/3 O 32 A Terminal block width 8 mm / 0.315 in 12 - 13 mrn / 0.49 in 4_ ^ O 500 V = 6 kV =


    OCR Scan
    PDF

    Contextual Info: CAGE CLAMP* 4-Level Same Potential Terminal Blocks Front-entry 2 x 0.08 - 1.5 mm2 2 x AWG 28 - 16 250 V /4 kV/3 O 300 V, 10 A W 18 A 300 V, 10 A a Terminal block width 7.62 mm / 0.3 in 1_ 8 - 1 0 mm / 0.35 in 2 x 0.08 - 1.5 mm2 2 x AWG 28 - 16 250 V/4 kV/3 O


    OCR Scan
    H03GD PDF

    Contextual Info: CAGE CLAM p 8-Level Same Potential Terminal Blocks C O N N E C T IO N Front-entry O 2 x 0 .0 8 -1 .5 m m 2 2xAW G 28 -16 250 V/4 kV/3 O 18 A - 1 2x0.08 - 1 .5 m m 2 2xAW G 2 8 -1 6 250 V/4 kV/3 O 18 A Terminal block width 7.62 mm / 0.3 in


    OCR Scan
    31-pole, PDF

    Contextual Info: 1 Double Deck Terminal Blocks Front-entry 0.08 - 2 .5 m m 2 400 V /6 kV /3 O 6.3 A 0 / 2 0 A 0.08 - 2 .5 m m 2 400 V/6 kV/3 O © 6.3 A 0 / 2 0 A AWG 28 - 14 300 V, 15 A TO 0 300 V, 20 A « 0 Terminal block width 5 mm / 0.197 in 4_ ^ 8 - 9 mm / 0.33 in


    OCR Scan
    10-way PDF

    Contextual Info: Sensor Terminal Blocks, for 3-Conductor Sensors 0.08 - 2.5 m m 2 400 V /6 kV/3 O 20 A AW G 28 - 12 300 V, 15 A W Terminal block width 5 mm / 0.197 in 4_M 8 - 9 mm / 0.33 in I O 4 00/250 V = rated voltage 6/4 kV = rated surge voltage 3 = pollution degree


    OCR Scan
    PDF

    Contextual Info: 1 Through Terminal Blocks Side-entry 0.08 - 1.5 m m 2 AWG 28 - 16 800 V/8 kV/3 O 600 V , 1 0 A « 600 V, 10 A 18 A Terminal block width 4 mm / 0.157 in i— * » « cam ®®® ®si & & s oi svutnv9 § ® 0.08 - 2 .5 m m 2 800 V/8 kV/3 O 24 A AWG 28 - 12


    OCR Scan
    V35GLBVlRNVÂ PDF

    Contextual Info: Rail-Mounted Terminal Blocks for Matrix Patching/ Wire Harness Support CAGE CLAMP Front-entry Wire harness support 0.08 - 1.5 m m 2 AWG 28-16 800 V/8 kV/3 O 18 A Terminal block width 5 mm / 0.197 in 1_ ^ 8 - 9 mm / 0.33 in O 800 V = rated voltage 8 kV = rated surge voltage


    OCR Scan
    harn098 PDF

    Contextual Info: Front-entry, Disconnect/test terminal blocks 26 For current or voltage transformer circuits 0.2 - 6 m m 2 A W G 2 4 - 10 0.2 - 6 m m 2 Accessories for disconnect/test terminal blocks AW G 2 4 - 1 0 5 0 0 V / 6 kV/3 30 A 5 0 0 V /6 kV/3 30 A Term inal b lo ck w idth 8 mm / 0 .3 1 5 in


    OCR Scan
    Colou282-424 PDF

    Contextual Info: Sensor Terminal Blocks, for 3-Conductor Sensors VO LU M E 1 0.08 - 2.5 m m 2 250 V/4 kV/3 O 18 A AW G 28 - 12 300 V, 10 A Terminal block width 5 mm / 0.197 in 1_ M 6 - 7 mm / 0.26 in O 250 V = 4 kV = 3 = see also Internal commoning 9 A 0.08 - 2.5 m m 2


    OCR Scan
    17-way PDF

    Contextual Info: 1 M 03G D Multilevel Installation Terminal Blocks 102 T O p jto b Front-entry 0 .0 8 - 4 m m 2 AWG 2 8 - 1 2 400 V /6 kV/3 O 300 V, 20 A TO 26 A Terminal block width 6 mm / 0.236 in / 0.37 in *TO H ®@ eG LBV O 400 V = 6 kV = 3 = see also 0 .0 8 - 4 m m 2


    OCR Scan
    PDF

    Contextual Info: Actuator Terminal Blocks for M agnetic Valves, Servom otors etc. 0.08 - 2 .5 m m 400 V /6 kV/3, 20 A O 250 V /4 kV/3, 20 A O AWG 28 - 12 300 V, 15 A W 300 V, 15 A a Terminal block width 5 mm / 0.197 in O 0.08 - 2 .5 m m 2 AWG 28 - 12 125 V /5 A © 250 V; 6.3 A TO


    OCR Scan
    PDF