3 PHASE UPS ONLINE Search Results
3 PHASE UPS ONLINE Result Highlights (5)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
TB6586BFG |
![]() |
Brushless Motor Driver/3 Phases Controller/Vout(V)=18/Square Wave |
![]() |
||
TB62213AFG |
![]() |
Stepping Motor Driver/Bipolar Type/Vout(V)=40/Iout(A)=3/Phase Interface |
![]() |
||
TB62261FTAG |
![]() |
Stepping Motor Driver/Bipolar Type/Vout(V)=40/Iout(A)=1.5/Phase Interface |
![]() |
||
TB6562ANG |
![]() |
Stepping Motor Driver/Bipolar Type/Vout(V)=40/Iout(A)=1.5/Phase Interface |
![]() |
||
TB67S141HG |
![]() |
Stepping Motor Driver/Unipolar Type/Vout(V)=84/Iout(A)=3/Phase Interface |
![]() |
3 PHASE UPS ONLINE Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
inverter 3 phase igbt output 380vContextual Info: SmartOnline 60kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS MODEL NUMBER: SU60KX Highlights 60,000 VA 60kVA 3-phase tower UPS N+1 redundant modular architecture helps assure 100% availability 1+1 parallel capability allows for |
Original |
60kVA SU60KX 60kVA) 220/380V, 230/400V 240/415V SU60KMBPKX SU60KX, inverter 3 phase igbt output 380v | |
3phase inverter using igbtContextual Info: SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS MODEL NUMBER: SU40KX Highlights 40,000 VA 40kVA 3-phase tower UPS N+1 redundant modular architecture helps assure 100% availability 1+1 parallel capability allows for |
Original |
40kVA SU40KX 40kVA) 220/380V, 230/400V 240/415V SU40KMBPKX 3phase inverter using igbt | |
Contextual Info: SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS MODEL NUMBER: SU80KX Highlights 80,000 VA 80kVA 3-phase tower UPS N+1 redundant modular architecture helps assure 100% availability 1+1 parallel capability allows for |
Original |
80kVA SU80KX 80kVA) 220/380V, 230/400V 240/415V SU80KMBPKX SU80KX | |
Contextual Info: Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: + 773 869 1234 E-mail: saleshelp@tripplite.com Model #: SU40KX SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS Highlights 40,000 VA (40kVA) 3-phase tower UPS |
Original |
SU40KX 40kVA 40kVA) 220/380V, 230/400V 240/415V SU40KMBPKX SUPC2MBP40KX SU40KX | |
Contextual Info: Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: + 773 869 1234 E-mail: saleshelp@tripplite.com Model #: SU60KX SmartOnline 60kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS Highlights 60,000 VA (60kVA) 3-phase tower UPS |
Original |
SU60KX 60kVA 60kVA) 220/380V, 230/400V 240/415V SU60KMBPKX SU60KX, SU60KTV SUPC2MBP60KX | |
Contextual Info: Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: + 773 869 1234 E-mail: saleshelp@tripplite.com Model #: SU80KX SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS Highlights 80,000 VA (80kVA) 3-phase tower UPS |
Original |
SU80KX 80kVA 80kVA) 220/380V, 230/400V 240/415V SU80KMBPKX SU80KX SU80KTV SUPC2MBP80KX | |
Contextual Info: SmartOnline 20kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS MODEL NUMBER: SU20KX Highlights 20,000 VA 20kVA 3-phase tower UPS 1+1 parallel capability allows for system redundancy or increased capacity Low THDi reduces installation costs by permitting 1:1 generator |
Original |
20kVA SU20KX 20kVA) 220/380V, 230/400V 240/415V SURBC2030 SU20KMBPK | |
Contextual Info: SmartOnline 3-Phase UPS System - 3-Phase on-line, double-conversion protection for mission-critical applications MODEL NUMBER: SU20K3/3X Highlights 20,000 VA 20kVA tower UPS with internal modular battery system User-selectable 3-phase 220/380 or 230/400 or 240/415V AC input |
Original |
SU20K3/3X 20kVA) 240/415V 56-280V AC/270-485V SU20K3/3X 20kVA 20kVA 30kVA SURBC2030 | |
8000w inverterContextual Info: SmartOnline 10kVA On-Line Double-Conversion UPS, 3 Phase Input, Single Phase Output Highlights 10,000 VA 10kVA extended run tower UPS MODEL NUMBER: SU10K3/1X 3-phase hardwire input (220/380, 230/400, 240/415 VAC) Single-phase hardwire output (user-selectable 220 or 230 or |
Original |
10kVA 10kVA) SU10K3/1X SU10K3/1X BP240V787C-1PH com/sku/SU10K3/1X. 8000w inverter | |
Contextual Info: SmartOnline 30kVA On-Line Double-Conversion UPS, 3 Phase input / output MODEL NUMBER: SU30K3/3 Highlights 30,000 VA 30kVA tower UPS with internal batteries Saves valuable space and simplifies runtime scalability 3-phase hardwire input and output (120/208VAC). Wide input |
Original |
30kVA SU30K3/3 30kVA) 120/208VAC) SU30K3/3 co40k) SUDC208V42P 20-60kVA | |
Contextual Info: Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: + 773 869 1234 E-mail: saleshelp@tripplite.com Model #: SU20KX SmartOnline 20kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS Highlights 20,000 VA (20kVA) 3-phase tower UPS 1+1 parallel capability allows for system redundancy or increased capacity |
Original |
SU20KX 20kVA 20kVA) 220/380V, 230/400V 240/415V SURBC2030 20kemperature, SU20KMBPK | |
Contextual Info: Internal Battery Pack - Compatible with Select SmartOnline 20kVA & 30kVA 3-Phase UPS System MODEL NUMBER: SURBC2030 Highlights Internal Battery Pack offers extended runtime operation for select Tripp Lite SmartOnline 20kVA and 30kVA 3-Phase UPS Systems Simple installation scheme with |
Original |
20kVA 30kVA SURBC2030 20kVA SURBC2030 SUBF2030 | |
Contextual Info: SmartOnline 60kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America MODEL NUMBER: SU60K Highlights 60,000 VA 60kVA tower UPS with 3 hot-swappable power modules N+1 redundant modular architecture helps ensure 100% availability 1+1 parallel capability allows for |
Original |
60kVA SU60K 60kVA) 120/208VAC) 94-150VAC/163-260VAC) SUDC208V84P 20-160kVA SUDC208V42P60M | |
Contextual Info: SmartOnline 16kVA On-Line Double-Conversion UPS, 8U Rack/Tower, 208/120V or 240/120V Hardwire output, Split phase input Highlights 16kVA / 16,000VA / 11,200W on-line double-conversion UPS, split phase input 208/120V or 240/120V +/-3% MODEL NUMBER: SU16000RT4UHW |
Original |
16kVA 208/120V 240/120V 000VA SU16000RT4UHW RS232 SU16000RT4UHW | |
|
|||
Contextual Info: Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: + 773 869 1234 E-mail: saleshelp@tripplite.com Model #: SU10K3/1X SmartOnline 10kVA On-Line Double-Conversion UPS, 3 Phase Input, Single Phase Output Highlights 10,000 VA (10kVA) extended run tower UPS |
Original |
SU10K3/1X 10kVA 10kVA) SU10K3/1X module87C-1PH | |
Contextual Info: SmartOnline 16kVA On-Line Double-Conversion UPS, 8U Rack/Tower, 208/120V or 240/120V Hardwire+NEMA outputs, Split phase input Highlights 16kVA / 16,000VA / 11,200W on-line double-conversion UPS, split phase input 208/120V or 240/120V +/-3% MODEL NUMBER: SU16000RT4U |
Original |
16kVA 208/120V 240/120V 000VA SU16000RT4U RS232 L6-30R, | |
Contextual Info: 20-60kVA 3 Phase Power Distribution Center MODEL NUMBER: SUDC208V42P Highlights Full size Rack Power Distribution Cabinet supports 20-60kVA 3 phase UPS power distribution in datacenter equipment racks 42 pole breaker panel supports 3 phase 208V and single phase |
Original |
20-60kVA SUDC208V42P SUDC208V42P SUWL530C-10 L5-30R SUWL530C-15 com/sku/SUDC208V42P. | |
Contextual Info: SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America MODEL NUMBER: SU80K Highlights 80,000 VA 80kVA tower UPS with 4 hot-swappable power modules N+1 redundant modular architecture helps ensure 100% availability 1+1 parallel capability allows for |
Original |
80kVA SU80K 80kVA) 120/208VAC) 94-150VAC/163-260VAC) SUDC208V84P 20-160kVA SUPC2MBP80K | |
Contextual Info: SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America MODEL NUMBER: SU40K Highlights 40,000 VA 40kVA tower UPS with 2 hot-swappable power modules N+1 redundant modular architecture helps assure 100% availability 1+1 parallel capability allows for |
Original |
40kVA SU40K 40kVA) 120/208VAC 4-150V AC/163-260V SUDC208V42P 20-60kVA | |
Contextual Info: SECTION Acm e Uninterruptible Power System s Acme Transformer offers one of the most comprehensive packages in the industry for 1-Phase and small 3-Phase UPS applications. Models are available in both standby SPS , 250 VA through 1400 VA and On-Line (UPS), 1000 VA |
OCR Scan |
250VAto RS232 | |
Contextual Info: Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: + 773 869 1234 E-mail: saleshelp@tripplite.com Model #: SU80K SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America Highlights 80,000 VA (80kVA) tower UPS with 4 hot-swappable power modules |
Original |
SU80K 80kVA 80kVA) 120/208VAC) 94-150VAC/163-260VAC) SUDC208V84P 20-160kVA SUPC2MBP80K SU80K | |
online ups service manualContextual Info: Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: + 773 869 1234 E-mail: saleshelp@tripplite.com Model #: SU40K SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America Highlights 40,000 VA (40kVA) tower UPS with 2 hot-swappable power modules |
Original |
SU40K 40kVA 40kVA) 120/208VAC 4-150V AC/163-260V 8V42P 20-60kVA SUDC208V42P40M online ups service manual | |
Contextual Info: Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: + 773 869 1234 E-mail: saleshelp@tripplite.com Model #: SU30K3/3 SmartOnline 30kVA On-Line Double-Conversion UPS, 3 Phase input / output Highlights 30,000 VA (30kVA) tower UPS with internal batteries |
Original |
SU30K3/3 30kVA 30kVA) 120/208VAC) SU30K3/3 SUDC208V42P 20-60kVA SUDC208V42P30M 20-30kVA | |
Contextual Info: SmartOnline 20kVA On-Line Double-Conversion UPS, 3 Phase input / output MODEL NUMBER: SU20K3/3 Highlights 20,000 VA 20kVA tower UPS with internal batteries Saves valuable space: power and battery components combined into a single small-footprint module Simplifies runtime scalability: |
Original |
20kVA SU20K3/3 20kVA) 120/208VAC) SU20K3/3 si40k) SUDC208V42P 20-60kVA SUDC208V42P30M |