Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    415V COIL DOL Search Results

    415V COIL DOL Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DFE2016CKA-1R0M=P2 Murata Manufacturing Co Ltd Fixed IND 1uH 1800mA NONAUTO Visit Murata Manufacturing Co Ltd
    LQW18CN55NJ0HD Murata Manufacturing Co Ltd Fixed IND 55nH 1500mA POWRTRN Visit Murata Manufacturing Co Ltd
    LQW18CNR56J0HD Murata Manufacturing Co Ltd Fixed IND 560nH 450mA POWRTRN Visit Murata Manufacturing Co Ltd
    DFE322520F-2R2M=P2 Murata Manufacturing Co Ltd Fixed IND 2.2uH 4400mA NONAUTO Visit Murata Manufacturing Co Ltd
    LQW18CN4N9D0HD Murata Manufacturing Co Ltd Fixed IND 4.9nH 2600mA POWRTRN Visit Murata Manufacturing Co Ltd

    415V COIL DOL Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    axc3

    Abstract: axc4 capacitor duty type contactor contactor coils 415v Ac contactor coils 415v MAX05 240V AC TO 12v DC CIRCUIT DIAGRAM DC 3 DUTY CONTACTOR axc4 coil MAX-03
    Text: Issued November 1991 012-384 Data Pack B Heating and lighting contactors Data Sheet Figure 1 Circuit diagram 240V 50/60Hz 415V supply coil supply L1 L2 L3 N A1 1 3 5 13 * A2 2 4 6 14 Neutral bar E General A range of contactors in ratings up to 100A for switching three phase heating and lighting loads. All contactors have a 240Vac coil and are fitted into an IP55


    Original
    PDF 50/60Hz 240Vac MAX03 MAX05 31mperature 660Vac 240Vdc axc3 axc4 capacitor duty type contactor contactor coils 415v Ac contactor coils 415v MAX05 240V AC TO 12v DC CIRCUIT DIAGRAM DC 3 DUTY CONTACTOR axc4 coil MAX-03

    EATON

    Abstract: 21MSULK star delta motor starter 404RDMP 22MSUL 21MSU2SK 28ARD1X 428ALCFP 22MSU 21MSUL
    Text: ADS8 Wall Chart 22/11/06 5:54 pm Page 1 ADS8 Motor starters and overload relays 9kW DOL starter without switch disconnect 25kW Star Delta starter without switch disconnect • IP 54 metalclad surface mounting enclosure, less overload relay • IP 65 moulded surface mounting enclosure, less overload relay


    Original
    PDF 28ADSM1X 50Hz1 48ADSM1X 28SDA2X18 2812004VCOA 4812004VCOA 2825004VCOA 4825004VCOA EATON 21MSULK star delta motor starter 404RDMP 22MSUL 21MSU2SK 28ARD1X 428ALCFP 22MSU 21MSUL

    140M-C-AFA11

    Abstract: 100-K05ZJ10 140M-C-PEK12 140M-C2E-C10 140M-C2E-B10 140M-C2E-C25 Allen-Bradley 100-k12 100-k05 140M-C-W454 140M-C2E-B16
    Text: MCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE DOL-Starter Overload Protection Short Circuit Protection DOL-Starter Overload Protection PROTECTION FOR AC AND DC MOTORS • The Bulletin 193-K thermal


    Original
    PDF 193-K 100-K 140-M MCS-SG001A-EN-P 140M-C-AFA11 100-K05ZJ10 140M-C-PEK12 140M-C2E-C10 140M-C2E-B10 140M-C2E-C25 Allen-Bradley 100-k12 100-k05 140M-C-W454 140M-C2E-B16

    3.7 KW induction motor 440v 3phase

    Abstract: contactor and overload start stop VDE0660 3 phase, 415v and 15 kw motor 1 KW induction motor 440v 3phase 3 phase squirrel cage induction motor remote control circuit of a phase induction motor 0.5 hp 3-PHASE induction motor bs5424 3 phase, 415v and 11 kw induction motor
    Text: Issued November 1990 B11044 Direct on line dol starters 0.5 to 10hp415Vac Features l Protected to IP54 l Robust sheet steel enclosure l 3-pole contactor to BS5424; IEC158-1 and VDE0660 l 20mm conduit entries. Robust direct on line ac starters complying with


    Original
    PDF B11044 415Vac BS4941; IEC292 VDE0660. BS5424; IEC158-1 VDE0660 220/240V 380/440V 3.7 KW induction motor 440v 3phase contactor and overload start stop 3 phase, 415v and 15 kw motor 1 KW induction motor 440v 3phase 3 phase squirrel cage induction motor remote control circuit of a phase induction motor 0.5 hp 3-PHASE induction motor bs5424 3 phase, 415v and 11 kw induction motor

    VDE0660

    Abstract: Starting Current 7.5KW Motor 440v vde-0660 380V 415v motor 3 phase, 415v and 11 kw induction motor bs5424 IEC158-1 IEC158 OVERLOAD RELAY 1 KW induction motor 440v 3phase
    Text: Issued November 1990 011-044 Data Pack B Direct on line dol starters 0.5 to 10hp 415Vac Data Sheet Robust direct on line ac starters complying with BS4941; IEC292 and VDE0660. Each unit is supplied ready wired with a 3-pole contactor. To complete the assembly an overload relay to match the full load current of the motor must be selected (Table 2). Housed


    Original
    PDF 415Vac BS4941; IEC292 VDE0660. 220/240V 380/440V BS5424; IEC158-1 VDE0660 VDE0660 Starting Current 7.5KW Motor 440v vde-0660 380V 415v motor 3 phase, 415v and 11 kw induction motor bs5424 IEC158 OVERLOAD RELAY 1 KW induction motor 440v 3phase

    VDE0660

    Abstract: 380V 415v 15kw motor vde-0660 3 phase, 415v and 11 kw induction motor 15 KW induction motor 440v 3phase Starting Current 7.5KW Motor 440v IEC292 380V 415v motor 3 phase, 415v and 37 kw motor single phase dol motor starter
    Text: Issued March 1997 232-3355 Data Pack B Direct on line dol starters 0.5 to 10hp 415Vac Data Sheet Robust direct on line ac starters complying with BS4941; IEC292 and VDE0660. Each unit is supplied ready wired with a 3-pole contactor. To complete the assembly an overload relay to match the full load current of the motor must be selected (Table 2). Housed


    Original
    PDF 415Vac BS4941; IEC292 VDE0660. 220/240V 380/440V BS5424; IEC158-1 VDE0660 VDE0660 380V 415v 15kw motor vde-0660 3 phase, 415v and 11 kw induction motor 15 KW induction motor 440v 3phase Starting Current 7.5KW Motor 440v 380V 415v motor 3 phase, 415v and 37 kw motor single phase dol motor starter

    7.5KW 3 phase motor 440v

    Abstract: Starting Current 7.5KW Motor 440v 15 KW induction motor 440v 3phase 380V 415v motor bs88 fuse 3 phase, 415v and 37 kw motor 0.5 hp 3-PHASE induction motor IEC158 VDE0660 11 KW 3-phase motor weight
    Text: Issued March 1994 017-064 Data Pack B Data Sheet Direct on line DOL starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated


    Original
    PDF 415Vac BS5424; IEC158 VDE0660 220/240V 15V/440V 7.5KW 3 phase motor 440v Starting Current 7.5KW Motor 440v 15 KW induction motor 440v 3phase 380V 415v motor bs88 fuse 3 phase, 415v and 37 kw motor 0.5 hp 3-PHASE induction motor 11 KW 3-phase motor weight

    PILOT LIGHT 230V

    Abstract: dol starter 84EXE0D-OL
    Text: Control - Direct-on-Line Starters IP66 Plastic Enclosure Three Phase 400v up to 7.5kW - 400v coil • Smoothly styled modern IP66 enclosed DOL starter, with generous cabling space for easy installation. Combined contactor/overload assembly can be unclipped from DIN rail to ease installation.


    Original
    PDF 82EXE0D-OL 122EXE0D-OL 182EXE0D-OL PILOT LIGHT 230V dol starter 84EXE0D-OL

    Starting Current 7.5KW Motor 440v

    Abstract: 7.5KW 3 phase motor 440v 3 phase, 415v and 11 kw induction motor 380V 415v 15kw motor 0.5 hp 3-PHASE induction motor 380v motor overload protection 15 KW induction motor 440v 3phase 220v motor overload protection contactor and overload start stop 3 phase motor start with contactor
    Text: B17064 Issued March 1994 Directonline DOL starters 0.5to10hp415VacProtectedtoIP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated enclosure environmentally protected to IP66. The


    Original
    PDF B17064 415Vac BS5424; IEC158 VDE0660 220/240V 15V/440V Starting Current 7.5KW Motor 440v 7.5KW 3 phase motor 440v 3 phase, 415v and 11 kw induction motor 380V 415v 15kw motor 0.5 hp 3-PHASE induction motor 380v motor overload protection 15 KW induction motor 440v 3phase 220v motor overload protection contactor and overload start stop 3 phase motor start with contactor

    Starting Current 7.5KW Motor 440v

    Abstract: 7.5KW 3 phase motor 440v contactor and overload start stop 1 KW induction motor 440v 3phase OVERLOAD RELAY bs5424 15 KW induction motor 440v 3phase 0.5 hp 3-PHASE induction motor 440V 50HZ dol starter
    Text: Issued March 1999 232-4493 Data Pack B Data Sheet Direct on line DOL starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated


    Original
    PDF 415Vac BS5424; IEC158 VDE0660 220/240V 15V/440V Starting Current 7.5KW Motor 440v 7.5KW 3 phase motor 440v contactor and overload start stop 1 KW induction motor 440v 3phase OVERLOAD RELAY bs5424 15 KW induction motor 440v 3phase 0.5 hp 3-PHASE induction motor 440V 50HZ dol starter

    15 KW induction motor 440v 3phase

    Abstract: Starting Current 7.5KW Motor 440v 3 phase, 415v and 37 kw motor 7.5KW 3 phase motor 440v contactor coils 415v contactor 220V 3 phase 3 phase, 415v and 15 kw motor DOL starting of 3-Phase induction motor 380V 415v motor 100 hp contactor and overload start stop
    Text: Issued March 1997 232-4493 Data Pack B Data Sheet Direct on line DOL starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated


    Original
    PDF 415Vac BS5424; IEC158 VDE0660 220/240V 15V/440V 15 KW induction motor 440v 3phase Starting Current 7.5KW Motor 440v 3 phase, 415v and 37 kw motor 7.5KW 3 phase motor 440v contactor coils 415v contactor 220V 3 phase 3 phase, 415v and 15 kw motor DOL starting of 3-Phase induction motor 380V 415v motor 100 hp contactor and overload start stop

    SIEMENS 3TF47 contactor

    Abstract: 3UA50 siemens modules GR 60 48 V 120 A 3TF52 3UA62 SIEMENS 3TF46 contactor siemens mpcb 3TK2827 3tf54 3tf35
    Text: Unmatched safety that meets all your needs LV Switchgear Price List Maximum Retail Price w.e.f. 1st November, 2010 Answers for industry. s Everything Easy SIRIUS SIEMENS – INDUSTRY SECTOR TRAINING CENTER SITRAIN INDIA, KALWA. List of courses at SITRAIN-Kalwa & Authorized Training Centers ATC


    Original
    PDF S7-200 S7-300 S7-400 SGR-01-114-069 SGR-01-114-054 SGR-01-103-051) SIEMENS 3TF47 contactor 3UA50 siemens modules GR 60 48 V 120 A 3TF52 3UA62 SIEMENS 3TF46 contactor siemens mpcb 3TK2827 3tf54 3tf35

    wiring diagram contactor with push button

    Abstract: wiring diagram dol starter wiring diagram contactor wiring diagram for single phase dol motor starter three phase DOL starter wiring wiring diagram dol motor starter three phase diagram dol motor starter contactor 3 phase Wiring Diagram 48ADS1X 380-415V
    Text: 36326 ADS8 Brochure 3/8/05 4:11 pm Page 3 ADS8 IP54 Direct-On-Line Starter Technical Focus • Replaces ADS7 • Rated up to 9kW 36326 ADS8 Brochure 3/8/05 4:11 pm Page 4 New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range


    Original
    PDF TD03406001U wiring diagram contactor with push button wiring diagram dol starter wiring diagram contactor wiring diagram for single phase dol motor starter three phase DOL starter wiring wiring diagram dol motor starter three phase diagram dol motor starter contactor 3 phase Wiring Diagram 48ADS1X 380-415V

    telemecanique contactor catalogue

    Abstract: telemecanique VDE 0660 telemecanique DOL motor starter telemecanique LC1 IEC 292-1 telemecanique lc1 contactor catalogue telemecanique thermal overload relay Telemecanique MOTOR STARTER table telemecanique contactor catalogue LC1 contactor telemecanique LC1
    Text: Issued November 1991 012-570 Data Pack B Data Sheet Direct on line DOL starters Telemecanique ‘d2’ range A range of 4 and 9kW direct on line ac starters using the new Telemecanique ‘d2’ motor control gear range and conforming to IEC 947-4, IEC 292-1, BS4941 and


    Original
    PDF BS4941 2xPE16 telemecanique contactor catalogue telemecanique VDE 0660 telemecanique DOL motor starter telemecanique LC1 IEC 292-1 telemecanique lc1 contactor catalogue telemecanique thermal overload relay Telemecanique MOTOR STARTER table telemecanique contactor catalogue LC1 contactor telemecanique LC1

    telemecanique contactor catalogue

    Abstract: telemecanique contactor SIZE 1 telemecanique LC1 Telemecanique MOTOR STARTER table IEC 292-1 3 phase Overload Telemecanique telemecanique thermal overload relay telemecanique DOL motor starter LP1 CONTACTOR TELEMECANIQUE "IEC 292-1"
    Text: Issued November 1991 B12570 Direct on line DOL starters TelemecaniqueÔd2Õ range A range of 4 and 9kW direct on line ac starters using the new Telemecanique Ôd2Õ motor control gear range and conforming to IEC 947-4, IEC 292-1, BS4941 and VDE 0660. RS stock no.


    Original
    PDF B12570 BS4941 corr32 2xPE13 2xPE16 telemecanique contactor catalogue telemecanique contactor SIZE 1 telemecanique LC1 Telemecanique MOTOR STARTER table IEC 292-1 3 phase Overload Telemecanique telemecanique thermal overload relay telemecanique DOL motor starter LP1 CONTACTOR TELEMECANIQUE "IEC 292-1"

    3phase winding data 3.7 kw to 110 kw

    Abstract: 100S-D250 100S-C43 100S-D420 100S-D180 3 phase, 415v and 37 kw motor 100s-c23 100SD630 100S-C72 3 phase, 415v and 45 kw motor
    Text: Contactors & Control Relays Safety Contactors 100S-D Specifications Conformity to Standards IEC 60947-4 IEC 60947-4 Annex F IEC 60947 Type “2” Coordination CSA 22.2 No. 14 UL 508 Approvals Description Bulletin 100S-D safety contactors are designed to provide safe


    Original
    PDF 100S-D 100S-D 100S-C0905C. C2305C 100S-C0914C. C2314C 100S-C3004C. C8504C 100S-C09404C. C23404C 3phase winding data 3.7 kw to 110 kw 100S-D250 100S-C43 100S-D420 100S-D180 3 phase, 415v and 37 kw motor 100s-c23 100SD630 100S-C72 3 phase, 415v and 45 kw motor

    telemecanique contactor catalogue

    Abstract: telemecanique star delta starter bs88 zs levels HRC fuse gg GEC BS88-2 15KW motor telemecanique star delta starter table NIT16 gec mte axto overload BS88 fuse curve hbc
    Text: Issued March 1997 232-3608 Data Pack B Data Sheet BS88 HBC Fuselinks, type T HBC* fuselinks ASTA* certified to BS88: Part 2: 1975, suitable for general purpose industrial applications eg. heating and lighting circuits and for short circuit protection of motor control circuits.


    Original
    PDF IEC269: RS20H RS32H RS63H RS100H telemecanique contactor catalogue telemecanique star delta starter bs88 zs levels HRC fuse gg GEC BS88-2 15KW motor telemecanique star delta starter table NIT16 gec mte axto overload BS88 fuse curve hbc

    telemecanique contactor catalogue

    Abstract: telemecanique star delta starter HRC fuse gg GEC bs88 zs levels mte axto overload NIT16 gec gec switchgear TIA32 mte max0 TIS63M80 curve
    Text: Issued March 1992 012-659 Data Pack B Data Sheet BS88 HBC Fuselinks, type T HBC* fuselinks ASTA* certified to BS88: Part 2: 1975, suitable for general purpose industrial applications eg. heating and lighting circuits and for short circuit protection of motor control circuits.


    Original
    PDF IEC269: RS20H RS32H RS63H RS100H telemecanique contactor catalogue telemecanique star delta starter HRC fuse gg GEC bs88 zs levels mte axto overload NIT16 gec gec switchgear TIA32 mte max0 TIS63M80 curve

    telemecanique contactor catalogue

    Abstract: HRC fuse gg GEC telemecanique thermal overload relay tripping curve telemecanique star delta starter mte thermal overload relay mte axto overload BS88 gM motor fuse mte relay what is type 2 coordination TIA16
    Text: Issued March 1992 B12659 BS88 HBC Fuselinks, typeT HBC* fuselinks ASTA* certified to BS88: Part 2: 1975, suitable for general purpose industrial applications eg. heating and lighting circuits and for short circuit protection of motor control circuits. These fuselinks also meet all the requirements of


    Original
    PDF B12659 IEC269: RS20H RS32H RS63H RS100H RS200H RS20H RS32H RS63H telemecanique contactor catalogue HRC fuse gg GEC telemecanique thermal overload relay tripping curve telemecanique star delta starter mte thermal overload relay mte axto overload BS88 gM motor fuse mte relay what is type 2 coordination TIA16

    telemecanique contactor catalogue

    Abstract: telemecanique LC1 telemecanique thermal overload relay telemecanique VDE 0660 telemecanique lc1 contactor catalogue contactor telemecanique LC1 telemecanique contactor LC1 Telemecanique MOTOR STARTER telemecanique DOL motor starter LP1 CONTACTOR TELEMECANIQUE
    Text: Issued March 1997 232-3591 Data Pack B Data Sheet Direct on line DOL starters Telemecanique ‘d2’ range A range of 4 and 9kW direct on line ac starters using the new Telemecanique ‘d2’ motor control gear range and conforming to IEC 947-4, IEC 292-1, BS4941 and


    Original
    PDF BS4941 circula135 2xPE16 telemecanique contactor catalogue telemecanique LC1 telemecanique thermal overload relay telemecanique VDE 0660 telemecanique lc1 contactor catalogue contactor telemecanique LC1 telemecanique contactor LC1 Telemecanique MOTOR STARTER telemecanique DOL motor starter LP1 CONTACTOR TELEMECANIQUE

    Allen-Bradley 100-k12

    Abstract: 140M-C-ASA11 140m-c-wte 100-KFSD250 100-K09 140M-C-AFA11 100-KFC22 140M-C-WBE 100-KFSV55 100-K05ZJ10
    Text: SELECTION GUIDE BULLETIN 100-K Miniature Modular Control Sytstem 2 Bulletin 100-K, 700-K, 193-K, 140M, 140F IEC Miniature Contactors Selection Overview IEC Miniature Contactors • Bulletin 100/104-K Miniature Contactors Page 4 IEC Miniature Control Relays


    Original
    PDF 100-K 100-K, 700-K, 193-K, 100/104-K 700-K 193-K 100/104-K 100K-SG001A-EN-P Allen-Bradley 100-k12 140M-C-ASA11 140m-c-wte 100-KFSD250 100-K09 140M-C-AFA11 100-KFC22 140M-C-WBE 100-KFSV55 100-K05ZJ10

    Sprecher Schuh LE 2-16

    Abstract: TE404 Sprecher Schuh LE 2-20 Sprecher Schuh CA 3-9 m40 Sprecher Schuh CA 3-9 Sprecher Schuh LE 2-12 sprecher and schuh ca 4-9 TA473 CRD7-250 TD719
    Text: Contactors - AC Coil Four Pole - Series CA7 A Non-Reversing, Four Pole Contactors With AC Coil, Series CA7 Open type only Contactors Ratings for Switching AC Motors (AC2 / AC3 / AC4) Open Type Contact Configuration, Ie [A] kW (50 Hz) UL/CSA HP (60 Hz) Main Pole Catalog


    Original
    PDF CA7-9-M40- CA7-9-M31- CA7-9-M22- CA7-12-M40- CA7-12-M31- CA7-12-M22- Sprecher Schuh LE 2-16 TE404 Sprecher Schuh LE 2-20 Sprecher Schuh CA 3-9 m40 Sprecher Schuh CA 3-9 Sprecher Schuh LE 2-12 sprecher and schuh ca 4-9 TA473 CRD7-250 TD719

    Allen-Bradley 100-M09

    Abstract: 100-C09D10 KRY 112 71/2 193-EF1A Allen-Bradley 100-c09*10 193-EF2A 193-EF 140M-C2E-C10 Allen-Bradley 100-c09D10 140M-C-AFA11
    Text: Bulletin 100 Line IEC Contactors, Starters, and Overload Relays Section Overview Motor Protection Circuit Breakers • Bulletin 140M Motor Protection Circuit Breakers Page 5 • Bulletin 140M Motor Circuit Protectors Page 7 • Bulletin 140M Accessories


    Original
    PDF 100/104-M 100/104-C 100/104-D 100-G 100S/104S TZ734 TZ747 TZ779 TZ780 TZS734 Allen-Bradley 100-M09 100-C09D10 KRY 112 71/2 193-EF1A Allen-Bradley 100-c09*10 193-EF2A 193-EF 140M-C2E-C10 Allen-Bradley 100-c09D10 140M-C-AFA11

    wiring diagram dol motor starter

    Abstract: dol starter K2-09A10 starter for 1.5 hp motors K2-16A10 k2-09a10 wiring diagram START-STOP wiring diagram contactor wiring start dol contactor coils 415v
    Text: DOL Starters P1M ❚ Up to 7.5kW ❚ IP65 enclosure ❚ Start-Stop pushbuttons ❚ Hand-Off-Auto selector ❚ Wired to accept overload ❚ Indicator ❚ Anti-condensation heater Options and ordering codes P1 Series M T P1 M20 x 1.5 conduit knockouts Start-stop pushbuttons


    Original
    PDF 20-240V 80-415V P1M/03/03 K2-09A10 U1216E K2-16A10 15/hour U1216E0 wiring diagram dol motor starter dol starter K2-09A10 starter for 1.5 hp motors K2-16A10 k2-09a10 wiring diagram START-STOP wiring diagram contactor wiring start dol contactor coils 415v