Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MTL5500 Search Results

    MTL5500 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    MTL5544D

    Abstract: MTL5575 MTL5516 MTL5546Y MTL5504 MTL5517 MTL5541S MTL5532
    Text: MTL5500 Series isolating interface units Instruction Manual INM5500 ii INM5500-4 October 2013 Contents 1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1


    Original
    PDF MTL5500 INM5500 INM5500-4 MTL5544D MTL5575 MTL5516 MTL5546Y MTL5504 MTL5517 MTL5541S MTL5532

    MTL5073

    Abstract: MTL4073 MTL4075 PCL45USB MTL5074 MTL5500 MTL4000 5 Pole 3.5mm jack socket plug 3.5mm MTL4500
    Text: PCS45/PCL45USB CONFIGURATOR FOR MTL CONVERTERS MPA5500 A.C. POWER ADAPTOR The MPA5500 enables any MTL5500 Series module that is normally powered from a nominal 24V DC supply i.e. those that are not looppowered to be powered from a high-voltage AC supply.


    Original
    PDF PCS45/PCL45USB MPA5500 MPA5500 MTL5500 MTL5500 PCS45/PCL45USB PCS45) PCS45 EPS45/5500 MTL5073 MTL4073 MTL4075 PCL45USB MTL5074 MTL4000 5 Pole 3.5mm jack socket plug 3.5mm MTL4500

    mtl5541

    Abstract: dc 8069 4.20 mA Transmitter hart hazardous area
    Text: EPS5541-1 Hazardous area Safe area MTL5541 REPEATER POWER SUPPLY 6 5 4 2 4/20mA – 1 The MTL5541 provides a fully-floating dc supply for energising a conventional 2- or 3-wire 4/20mA transmitter which is located in a hazardous area, and repeats the current in another floating circuit to


    Original
    PDF EPS5541-1 MTL5541 4/20mA 4/20mA 4/20mA, dc 8069 4.20 mA Transmitter hart hazardous area

    MTL5511

    Abstract: METAL DETECTOR circuit for make namur standard 9v relay switch dc 8069 proximity detector sensor Proximity Detectors for metal detector 9v single RELAY EPS5511-2 metal proximity detector sensor
    Text: EPS5511-2 Hazardous area MTL5511 SWITCH/ PROXIMITY DETECTOR INTERFACE Safe area To earth leakage detector Switch-type sensors require resistors if LFD is selected single channel, with line fault detection 6 5 4 680W 22kW The MTL5511 enables a safe-area load to be controlled by a switch


    Original
    PDF EPS5511-2 MTL5511 METAL DETECTOR circuit for make namur standard 9v relay switch dc 8069 proximity detector sensor Proximity Detectors for metal detector 9v single RELAY EPS5511-2 metal proximity detector sensor

    MTL5549

    Abstract: MTL5549Y TAG 281 800 MTL5500 Hand-Held Communicator 24V 4.....20MA TH500 TH5000
    Text: EPS5549/49Y-3 Hazardous area Safe area MTL5549/5549Y ISOLATING DRIVER two-channel, for 4–20mA smart valve positioners with line fault detection Ch 2 P I I Terminal 1 2 4 5 8 9 11 12 13 14 Number of channels Two Location of I/P converter Zone 0, IIC, T4–6 hazardous area if suitably certified


    Original
    PDF EPS5549/49Y-3 MTL5549/5549Y 4/20mA 500Hz 10kHz MTL5549 MTL5549Y TAG 281 800 MTL5500 Hand-Held Communicator 24V 4.....20MA TH500 TH5000

    MTL5516c

    Abstract: dc 8069 METAL DETECTOR circuit for make 9v relay switch proximity detector sensor 24v 8 channel Relay Metal Detector metal proximity detector sensor namur standard Proximity Detectors for metal detector
    Text: EPS5516C-2 Hazardous area MTL5516C SWITCH/ PROXIMITY DETECTOR INTERFACE 680W 22kW two-channel, with line fault detection 680W The MTL5516C enables two safe-area loads to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are


    Original
    PDF EPS5516C-2 MTL5516C dc 8069 METAL DETECTOR circuit for make 9v relay switch proximity detector sensor 24v 8 channel Relay Metal Detector metal proximity detector sensor namur standard Proximity Detectors for metal detector

    MTL5546

    Abstract: dc 8069 24V 4.....20MA Isolated 4-20ma Voltage to Current Converter circuit 4-20mA valve positioners voltage to current converter 4 to 20ma circuit TH5000 a-4-20mA
    Text: EPS5546-2 Hazardous area MTL5546 ISOLATING DRIVER Safe area for 4–20mA smart valve positioners with line fault detection 6 5 4 + 3 P I The MTL5546 accepts a 4/20mA floating signal from a safe-area controller to drive a current/pressure converter or any other load up


    Original
    PDF EPS5546-2 MTL5546 MTL5546 4/20mA 4/20mA dc 8069 24V 4.....20MA Isolated 4-20ma Voltage to Current Converter circuit 4-20mA valve positioners voltage to current converter 4 to 20ma circuit TH5000 a-4-20mA

    dc 8069

    Abstract: MTL5501-SR METAL DETECTOR circuit for make metal proximity detector sensor TH5000 1507M Proximity Detectors for metal detector detector SWITCH hazardous area Metal Detector
    Text: EPS5501SR–1 Hazardous area MTL5501-SR FAILSAFE SWITCH/PROXIMITY DETECTOR INTERFACE Resistors must always be fitted for switch inputs with LFD 6 5 4 1k4W 10kW With the MTL5501-SR, a fail–safe switch/proximity detector located in the hazardous area can control an isolated fail–safe


    Original
    PDF EPS5501SR MTL5501-SR MTL5501-SR, MTL5501 dc 8069 METAL DETECTOR circuit for make metal proximity detector sensor TH5000 1507M Proximity Detectors for metal detector detector SWITCH hazardous area Metal Detector

    dc 8069

    Abstract: 24v 8 channel Relay MTL5526 MTL5500 normally closed normally open operation of relay transistor 8069
    Text: EPS5526-1 All contacts shown in normal position relays de-energised 13 14 Control 20 to 35V dc Vs– Vs+ 20 to 35V dc * this link applies only to contact/logic operation Terminal 1 2 3 4 5 6 8 9 10 11 13 14 SPECIFICATION See also common specification Number of channels


    Original
    PDF EPS5526-1 dc 8069 24v 8 channel Relay MTL5526 MTL5500 normally closed normally open operation of relay transistor 8069

    MTL5544

    Abstract: EPS5544-1 dc 8069 TH500 4.20 mA Transmitter current transmitter 4...20 mA TH5000
    Text: EPS5544-1 Hazardous area MTL5544 REPEATER POWER SUPPLY Safe area Ch 2 two channel, 4/20mA, smart, for 2- or 3- wire transmitters 6 4/20mA – 4 3 2 – 1 + – Ch 2 Load 4/20mA + – Ch 1 Load 4/20mA + Vs– Vs+ 13 14 Ch 1 20 to 35V dc Terminal SPECIFICATION Function


    Original
    PDF EPS5544-1 MTL5544 4/20mA, 4/20mA EPS5544-1 dc 8069 TH500 4.20 mA Transmitter current transmitter 4...20 mA TH5000

    namur standard

    Abstract: Proximity Detectors for metal detector dc 8069 MTL5513 METAL DETECTOR circuit for make proximity detector sensor TH5000 110g metal proximity detector sensor proximity sensor interface
    Text: EPS5513-2 Hazardous area MTL5513 SWITCH/ PROXIMITY DETECTOR INTERFACE Switch-type sensors require resistors if LFD is selected 680W two-channel, with line fault detection and phase reversal 22kW To earth leakage detector + 6 7 8 9 5 – 4 680W The MTL5513 enables two solid-state outputs in the safe area to


    Original
    PDF EPS5513-2 MTL5513 namur standard Proximity Detectors for metal detector dc 8069 METAL DETECTOR circuit for make proximity detector sensor TH5000 110g metal proximity detector sensor proximity sensor interface

    dc 8069

    Abstract: intrinsically safe METAL DETECTOR circuit for make MTL5521 hart hazardous area EPS5521-2
    Text: EPS5521-2 Hazardous area MTL5521 SOLENOID/ ALARM DRIVER Safe area To earth leakage detector loop-powered, IIC 6 5 4 3 2 – 1 + The MTL5521 is a loop-powered module which enables a device located in the hazardous area to be controlled from the safe area. The MTL5521 can drive a certified intrinsically safe low-power load,


    Original
    PDF EPS5521-2 MTL5521 35Vdc dc 8069 intrinsically safe METAL DETECTOR circuit for make hart hazardous area EPS5521-2