Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    AVERAGE VOLTAGE MEASURMENT Search Results

    AVERAGE VOLTAGE MEASURMENT Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DF2B5M4ASL Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-3.6 V, SOD-962 (SL2) Visit Toshiba Electronic Devices & Storage Corporation
    DF2B6M4ASL Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-5.5 V, SOD-962 (SL2) Visit Toshiba Electronic Devices & Storage Corporation
    DF2B5PCT Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-3.6 V, SOD-882 (CST2) Visit Toshiba Electronic Devices & Storage Corporation
    DF2B7PCT Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-5.5 V, SOD-882 (CST2) Visit Toshiba Electronic Devices & Storage Corporation
    TPD4207F Toshiba Electronic Devices & Storage Corporation Intelligent power device 600V (High voltage PWM DC brushless motor driver) Visit Toshiba Electronic Devices & Storage Corporation

    AVERAGE VOLTAGE MEASURMENT Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    keithley 2002

    Abstract: X3100 7493 7493 pc Keithley 160 AN142 HP6626 X24C16
    Text: Application Note AN142 X3100 Current Measurment Accuracy Description This test measures the accuracy of the current sense amplifier circuit of the X3100. In the test, a known current is applied through a sense resistor to generate a voltage between the current sense inputs of the X3100.


    Original
    PDF AN142 X3100 X3100. 200uV 100mV. X24C16, keithley 2002 7493 7493 pc Keithley 160 AN142 HP6626 X24C16

    GTO switching test mitsubishi

    Abstract: gto 100A 200a gto FGR3000FX-90DA GTO switching test GTO peak reverse test mitsubishi
    Text: MITSUBISHI REVERSE-CONDUCTING GTO THYRISTORS FGR3000FX-90DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FGR3000FX-90DA Dimensions in mm GATE WHITE 500 ± 8 AUXILIARY CATHODE CONNECTOR (RED) 26 ± 0.5 ● ITQRM Repetitive controllable on-state current .3000A


    Original
    PDF FGR3000FX-90DA GTO switching test mitsubishi gto 100A 200a gto FGR3000FX-90DA GTO switching test GTO peak reverse test mitsubishi

    120D-22

    Abstract: FG6000AU-120D 60uf Gate Turn-Off Thyristors
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG6000AU-120D HIGH POWER INVERTER USE PRESS PACK TYPE FG6000AU-120D OUTLINE DRAWING Dimension in mm GATE WHITE 300 ± 8 AUXILIARY CATHODE CONNECTOR (RED) 0.4 min 0.4 min ● ITQRM Repetitive controllable on-state current .6000A


    Original
    PDF FG6000AU-120D 120D-22 FG6000AU-120D 60uf Gate Turn-Off Thyristors

    MITSUBISHI GATE TURN-OFF THYRISTORS

    Abstract: 200a gto gto 200A FGR3000CV-90DA GTO 100A gto 2400 GTO switching test mitsubishi gto mitsubishi 4500V 900A
    Text: MITSUBISHI REVERSE-CONDUCTING GTO THYRISTORS FGR3000CV-90DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FGR3000CV-90DA Dimensions in mm GATE WHITE 500 ± 8 AUXILIARY CATHODE CONNECTOR (RED) 26 ± 0.5 ● ITQRM Repetitive controllable on-state current .3000A


    Original
    PDF FGR3000CV-90DA MITSUBISHI GATE TURN-OFF THYRISTORS 200a gto gto 200A FGR3000CV-90DA GTO 100A gto 2400 GTO switching test mitsubishi gto mitsubishi 4500V 900A

    Untitled

    Abstract: No abstract text available
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG6000AU-120D HIGH POWER INVERTER USE PRESS PACK TYPE FG6000AU-120D OUTLINE DRAWING Dimension in mm GATE WHITE 300 ± 8 AUXILIARY CATHODE CONNECTOR (RED) 0.4 min 0.4 min ● ITQRM Repetitive controllable on-state current .6000A


    Original
    PDF FG6000AU-120D

    FG3300AH-50DA

    Abstract: No abstract text available
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG3300AH-50DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FG3300AH-50DA Dimensions in mm GATE WHITE 412 ± 8 AUXILIARY CATHODE CONNECTOR (RED) 26 ± 0.5 ● ITQRM Repetitive controllable on-state current .3300A


    Original
    PDF FG3300AH-50DA 50DALS FG3300AH-50DA

    4500v

    Abstract: FG4000BX-90DA
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG4000BX-90DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FG4000BX-90DA Dimensions in mm GATE WHITE 500 ± 8 26 ± 0.5 ● ITQRM Repetitive controllable on-state current .3000A ● IT(AV) Average on-state current .1000A


    Original
    PDF FG4000BX-90DA 4500v FG4000BX-90DA

    Untitled

    Abstract: No abstract text available
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG4000CX-90DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FG4000CX-90DA Dimensions in mm GATE WHITE 500 ± 8 26 ± 0.5 ● ITQRM Repetitive controllable on-state current .4000A ● IT(AV) Average on-state current .1200A


    Original
    PDF FG4000CX-90DA

    Untitled

    Abstract: No abstract text available
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG1000BV-90DA HIGH POWER INVERTER USE PRESS PACK TYPE FG1000BV-90DA OUTLINE DRAWING Dimensions in mm GATE WHITE 353 ± 8 AUXILIARY CATHODE CONNECTOR (RED) 0.4 MIN f 47 f 3.5 ± 0.2 DEPTH 2.2 ± 0.2 CATHODE 0.4 MIN 26 ± 0.5


    Original
    PDF FG1000BV-90DA

    FG1000BV-90DA

    Abstract: No abstract text available
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG1000BV-90DA HIGH POWER INVERTER USE PRESS PACK TYPE FG1000BV-90DA OUTLINE DRAWING Dimensions in mm GATE WHITE 353 ± 8 AUXILIARY CATHODE CONNECTOR (RED) 0.4 MIN f 47 f 3.5 ± 0.2 DEPTH 2.2 ± 0.2 CATHODE 0.4 MIN 26 ± 0.5


    Original
    PDF FG1000BV-90DA FG1000BV-90DA

    4500v

    Abstract: FG3000GX-90DA inverter ls 600
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG3000GX-90DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FG3000GX-90DA Dimensions in mm GATE WHITE 494 ± 8 ● ITQRM Repetitive controllable on-state current .3000A ● IT(AV) Average on-state current .1000A


    Original
    PDF FG3000GX-90DA 4500v FG3000GX-90DA inverter ls 600

    FG4000CX-90DA

    Abstract: No abstract text available
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG4000CX-90DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FG4000CX-90DA Dimensions in mm GATE WHITE 500 ± 8 26 ± 0.5 ● ITQRM Repetitive controllable on-state current .4000A ● IT(AV) Average on-state current .1200A


    Original
    PDF FG4000CX-90DA FG4000CX-90DA

    40uf

    Abstract: MITSUBISHI GATE TURN-OFF THYRISTORS FG2000FX-50DA
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG2000FX-50DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FG2000FX-50DA Dimensions in mm GATE WHITE 400 ± 8 AUXILIARY CATHODE CONNECTOR (RED) 0.4 MIN ● ITQRM Repetitive controllable on-state current .2200A


    Original
    PDF FG2000FX-50DA 50D0A 40uf MITSUBISHI GATE TURN-OFF THYRISTORS FG2000FX-50DA

    FG3000DV-90DA

    Abstract: No abstract text available
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG3000DV-90DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FG3000DV-90DA Dimensions in mm GATE WHITE 412 ± 8 AUXILIARY CATHODE CONNECTOR (RED) 26 ± 0.5 ● ITQRM Repetitive controllable on-state current .3000A


    Original
    PDF FG3000DV-90DA FG3000DV-90DA

    Untitled

    Abstract: No abstract text available
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG3000GX-90DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FG3000GX-90DA Dimensions in mm GATE WHITE 494 ± 8 ● ITQRM Repetitive controllable on-state current .3000A ● IT(AV) Average on-state current .1000A


    Original
    PDF FG3000GX-90DA

    FG1000BV-90DA

    Abstract: No abstract text available
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG1000BV-90DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FG1000BV-90DA Dimensions in mm GATE WHITE 390 ± 8 0.4 MIN 26 ± 0.5 ● ITQRM Repetitive controllable on-state current .1000A ● IT(AV) Average on-state current .400A


    Original
    PDF FG1000BV-90DA FG1000BV-90DA

    FG4000EX-50DA

    Abstract: No abstract text available
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG4000EX-50DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FG4000EX-50DA Dimensions in mm GATE WHITE 500 ± 8 26 ± 0.5 ● ITQRM Repetitive controllable on-state current .4000A ● IT(AV) Average on-state current .1600A


    Original
    PDF FG4000EX-50DA FG4000EX-50DA

    Untitled

    Abstract: No abstract text available
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG3300AH-50DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FG3300AH-50DA Dimensions in mm GATE WHITE 412 ± 8 AUXILIARY CATHODE CONNECTOR (RED) 26 ± 0.5 ● ITQRM Repetitive controllable on-state current .3300A


    Original
    PDF FG3300AH-50DA

    Untitled

    Abstract: No abstract text available
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG4000BX-90DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FG4000BX-90DA Dimensions in mm GATE WHITE 500 ± 8 26 ± 0.5 ● ITQRM Repetitive controllable on-state current .3000A ● IT(AV) Average on-state current .1000A


    Original
    PDF FG4000BX-90DA

    MITSUBISHI GATE TURN-OFF THYRISTORS

    Abstract: FG2000JV-90DA
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG2000JV-90DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FG2000JV-90DA Dimension in mm GATE WHITE 356 ± 8 AUXILIARY CATHODE CONNECTOR (RED) 0.4 min ¡ITQRM Repetitive controllable on-state current . 2000A


    Original
    PDF FG2000JV-90DA MITSUBISHI GATE TURN-OFF THYRISTORS FG2000JV-90DA

    4500v

    Abstract: FG4000GX-90DA
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG4000GX-90DA HIGH POWER INVERTER USE PRESS PACK TYPE OUTLINE DRAWING FG4000GX-90DA Dimensions in mm GATE WHITE 555 ± 10 ● ITQRM Repetitive controllable on-state current .4000A ● IT(AV) Average on-state current .1200A


    Original
    PDF FG4000GX-90DA 4500v FG4000GX-90DA

    7,5 kw mitsubishi inverter

    Abstract: gto 100A 100A GTO GTO peak reverse test mitsubishi ODC20 GTO switching test mitsubishi
    Text: MITSUBISHI REVERSE-CONDUCTING GTO THYRISTORS FG R3000FX-90DA HIGH POWER INVERTER USE PRESS PACK TYPE APPLICATION Inverters, D.C. choppers, Induction heaters, D.C. to D.C. converters. MAXIMUM RATINGS Voltage class Parameter Symbol Unit 90DA Repetitive peak off-state voltage*


    OCR Scan
    PDF R3000FX-90DA 7,5 kw mitsubishi inverter gto 100A 100A GTO GTO peak reverse test mitsubishi ODC20 GTO switching test mitsubishi

    GTO switching test

    Abstract: 100A GTO gto mitsubishi GTO peak reverse test mitsubishi FGR3000FX-90DA GTO switching test mitsubishi dv 700 inverter M1037 GTO 5000 V mitsubishi gto
    Text: MITSUBISHI REVERSE-CONDUCTING GTO THYRISTORS FGR3000FX-90DA HIGH POWER INVERTER USE PRESS PACK TYPE FGR3000FX-90DA • Itq rm Repetitive controllable on-state current. 3 0 0 0 A • lT AV A v e ra g e o n -s ta te c u r r e n t . 7 8 0 A


    OCR Scan
    PDF R3000FX-90 FGR3000FX-90DA GTO switching test 100A GTO gto mitsubishi GTO peak reverse test mitsubishi FGR3000FX-90DA GTO switching test mitsubishi dv 700 inverter M1037 GTO 5000 V mitsubishi gto

    Untitled

    Abstract: No abstract text available
    Text: MITSUBISHI GATE TURN-OFF THYRISTORS FG2000FX-50DA HIGH POWER INVERTER USE PRESS PACK TYPE FG2000FX-50DA OUTLINE DRAWING Dimensions in mm C O N N E C T O R R E D • Itq rm Repetitive controllable on-state cu rre n t. 2 2 0 0 A • lT(AV) Average on-state current. 1050A


    OCR Scan
    PDF FG2000FX-50DA