Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    C14 CONNECTOR COVER Search Results

    C14 CONNECTOR COVER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    PQU650M-F-COVER
    Murata Manufacturing Co Ltd PQU650M Series - 3x5 Fan Cover Kit, RoHs Medical Visit Murata Manufacturing Co Ltd
    HD3SS0001RLLR
    Texas Instruments Thunderbolt™ Technology connector source selection switch 24-VQFN -40 to 85 Visit Texas Instruments Buy
    DRV88471RTER
    Texas Instruments 18-V, 2-A dual H-bridge motor driver with current regulation and independent half-bridge con 16-WQFN -40 to 125 Visit Texas Instruments
    ANALOGPRGBOOK
    Texas Instruments The Analog Engineer's Pocket Reference covers precision signal chain topics Visit Texas Instruments
    HDC2021DEBR
    Texas Instruments 2% RH ultra-low-power digital relative humidity sensor, tape cover 6-WSON -40 to 125 Visit Texas Instruments

    C14 CONNECTOR COVER Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Contextual Info: Felcom 64 POWER ENTRY MODULES WITHOUT LINE FILTER Plug removal necessary for fuse replacement IEC Appliance Connector C14 with modular extended Components 6421.005X.XX Appliance inlet Appliance outlet 6431.005X.XX Appliance inlet Switch Appliance outlet C14


    Original
    PDF

    Contextual Info: KP FH Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Fuseholder 1- or 2-pole Medical fuse drawer KPF Filter Module (not enclosed) Inlet with fuseholder (5x20 mm) C14 70° C Description Characteristics - Panel Mount:


    Original
    com/pg05 E93617 PDF

    IEC 384 14 II

    Contextual Info: GRM1 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Fuseholder, Line Switch 2-pole and Voltage Selector Snap-In Version C14 70° C Description Characteristics - Panel Mount: Snap-In Version from rear-side


    Original
    com/pg05 E93617 IEC 384 14 II PDF

    Contextual Info: 1074 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector with Line Switch C14 70°C Snap-In Version C14 70° C Description Characteristics - Panel Mount: Snap-in version, from front side, Appliance Inlet, Protection class


    Original
    com/pg05 E88880 250VAC; 1min/50Hz) PDF

    Contextual Info: KP FH Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Fuseholder 1- or 2-pole Medical fuse drawer KPF Filter Module (not enclosed) Inlet with fuseholder (5x20 mm) C14 70° C Description Characteristics - Panel Mount:


    Original
    com/pg05 E93617 PDF

    IEC 60 384 4

    Contextual Info: GRM1 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Fuseholder, Line Switch 2-pole and Voltage Selector C14 70° C Description Characteristics - Panel Mount: Snap-In Version from rear-side - 4 Functions:


    Original
    com/pg05 IEC 60 384 4 PDF

    Contextual Info: GRM1 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Fuseholder, Line Switch 2-pole and Voltage Selector C14 70° C Description Characteristics - Panel Mount: Snap-In Version from rear-side - 4 Functions:


    Original
    com/pg05 PDF

    Contextual Info: GRM1 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Fuseholder, Line Switch 2-pole and Voltage Selector C14 70° C Description Characteristics - Panel Mount: Snap-In Version from rear-side - 4 Functions:


    Original
    com/pg05 E93617 PDF

    m324

    Contextual Info: 8843.FL APPLIANCE COUPLERS IEC Appliance Connector C14, 70°C 8843-FL C14 70° C Description Weblinks - Panel Mount: Approvals: http://www.schurter.com/approvals RoHS: http://www.schurter.com/rohs - Screw-on from front side - Inlet, Pin temperature 70 °C, Protection class I


    Original
    8843-FL min/50 8843-FL m324 PDF

    Contextual Info: KP Outlet Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Appliance Plug F KPF Filter Module (not enclosed) Inlet with outlet C14 F 70° C 70° C Description Characteristics - Panel Mount: Sandwich/rear-side


    Original
    com/pg05 PDF

    Contextual Info: 4707 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Fuseholder 2-pole Plug removal necessary for fuse replacement Screw-On Version C14 70° C Description Characteristics - Panel Mount: Screw-on from front or rear-side


    Original
    com/pg05 -IP40 PDF

    Contextual Info: KEB2 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Line Switch 2-pole C14 70° C Description Characteristics - Panel Mount: Screw-on version from front or rear side, snap-in version from front side


    Original
    com/pg05 PDF

    Contextual Info: KP Outlet Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Appliance Plug F KPF Filter Module (not enclosed) Inlet with outlet C14 F 70° C 70° C Description Characteristics - Panel Mount: Sandwich/rear-side


    Original
    com/pg05 PDF

    Contextual Info: KEB1 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Line Switch 1-pole C14 70° C Description Characteristics - Panel Mount: Screw-on version from front or rear side, snap-in version from front side


    Original
    com/pg05 PDF

    Contextual Info: KP Outlet Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Appliance Plug F KPF Filter Module (not enclosed) Inlet with outlet C14 F 70° C 70° C Description Characteristics - Panel Mount: Sandwich/rear-side


    Original
    com/pg05 PDF

    Contextual Info: KP FH POWER ENTRY MODULES WITHOUT LINE FILTER Medical fuse drawer IEC Appliance Connector C14 with Fuseholder 1- or 2-pole Inlet with fuseholder (5x20 mm) KPF Filter Module (not enclosed) C14 70° C Description Characteristics - Panel Mount: Sandwich/rear-side


    Original
    PDF

    Contextual Info: KP Switch Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Line Switch 1- or 2-pole KPF Filter Module (not enclosed) Inlet with line switch C14 70° C Description Characteristics - Panel Mount: Sandwich/rear-side


    Original
    com/pg05 PDF

    Contextual Info: 6100-4 APPLIANCE COUPLERS IEC Appliance Connector C14, 70°C 6100-4 C14 70° C Description Other versions on request - Panel Mount: Snap-In Version from front side - Inlet, Pin temperature 70 °C, Protection class I - Solder terminals or quick connect terminals


    Original
    min/50 PDF

    Contextual Info: KM POWER ENTRY MODULES WITHOUT LINE FILTER IEC Appliance Connector C14 with Fuseholder and Line Switch 1- or 2-pole Plug removal necessary for fuse replacement KM with shield C14 70° C Description Characteristics - Panel Mount: Snap-In Version from front side


    Original
    PDF

    Contextual Info: KEB1 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Line Switch 1-pole C14 70° C Description Characteristics - Panel Mount: Screw-on version from front or rear side, snap-in version from front side


    Original
    com/pg05 PDF

    Contextual Info: 8843.FLR APPLIANCE COUPLERS IEC Appliance Connector C14, 70°C 8843-FLR C14 70° C Description Weblinks - Panel Mount: Screw-on from front side - Inlet, Pin temperature 70 °C, Protection class I - Screw Approvals: http://www.schurter.com/approvals RoHS: http://www.schurter.com/rohs


    Original
    8843-FLR min/50 8843-FLR PDF

    Contextual Info: GSF1 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Fuseholder 1- or 2-pole Screw-On Version Snap-In Version Pick & Place Version C14 70° C Description Characteristics - Panel Mount: Sandwich/rear-side - 2 Functions:


    Original
    com/pg05 PDF

    Contextual Info: KEB2 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Line Switch 2-pole C14 70° C Description Characteristics - Panel Mount: Screw-on version from front or rear side, snap-in version from front side


    Original
    com/pg05 PDF

    Contextual Info: KP Switch Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Connector C14 with Line Switch 1- or 2-pole Inlet with line switch KPF Filter Module (not enclosed) C14 70° C Description Characteristics - Panel Mount: Sandwich/rear-side


    Original
    com/pg05 PDF