Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    DC AUXILIARY RELAY Search Results

    DC AUXILIARY RELAY Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MGN1S1208MC-R7 Murata Manufacturing Co Ltd DC-DC 1W SM 12-8V GAN Visit Murata Manufacturing Co Ltd
    MGN1D120603MC-R7 Murata Manufacturing Co Ltd DC-DC 1W SM 12-6/-3V GAN Visit Murata Manufacturing Co Ltd
    MGN1S1212MC-R7 Murata Manufacturing Co Ltd DC-DC 1W SM 12-12V GAN Visit Murata Manufacturing Co Ltd
    MGN1S0508MC-R7 Murata Manufacturing Co Ltd DC-DC 1W SM 5-8V GAN Visit Murata Manufacturing Co Ltd
    MGN1S0512MC-R7 Murata Manufacturing Co Ltd DC-DC 1W SM 5-12V GAN Visit Murata Manufacturing Co Ltd
    SF Impression Pixel

    DC AUXILIARY RELAY Price and Stock

    Phoenix Contact MCR-2SP-UI-DC

    MCR limit value switch, with two adjustable relay contacts, with electrically isolated auxiliary power supply, input signal 0...10 V/0..20 mA
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Onlinecomponents.com MCR-2SP-UI-DC
    • 1 $0
    • 10 $0
    • 100 $0
    • 1000 $0
    • 10000 $0
    Buy Now

    DC AUXILIARY RELAY Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    F0205

    Abstract: timer contactor timer vde 0110 on delay timer circuit diagram EEC contactors dc contactor DC-12 F0003 R0100 R5000
    Text: Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics 2CDC 251 060 F0003   Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width 22.5 mm Approvals 1 2 a f cULus CCC Marks


    Original
    PDF F0003 R5000 R6000 R0100 applicat109 F0005 F0205 timer contactor timer vde 0110 on delay timer circuit diagram EEC contactors dc contactor DC-12 F0003 R0100 R5000

    ABB contactor

    Abstract: contactor eg 315 F0003 contactor EG 160 dc contactor ABB CONTACTOR contact material R6000 225/ASEA EG 315 contactor vde 0110 timer R0100
    Text: Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics 2CDC 251 060 F0003 �� Single-function OFF-delay timer for DC contactors, without auxiliary voltage �� Width 22.5 mm Approvals 1 2 A cULus


    Original
    PDF F0003 R6000 R5000 R0100 ABB contactor contactor eg 315 F0003 contactor EG 160 dc contactor ABB CONTACTOR contact material R6000 225/ASEA EG 315 contactor vde 0110 timer R0100

    Untitled

    Abstract: No abstract text available
    Text: Product data sheet 3RA2815-2FW10 SOLID-STATE TIME-DELAY AUXILIARY SWITCH, OFF-DELAY WITHOUT AUXILIARY VOLTAGE RELAY 1 NC + 1 NO 24.240V AC/DC TIME RANGE 0.05.100S FOR SNAPPING ONTO THE FRONT; FOR 3RT2 CONTACTORS SPRING-TYPE TERMINALS INTEGRATED VARISTOR FOR DAMPING CONTACTOR


    Original
    PDF 3RA2815-2FW10 com/WW/view/en/3RA2815-2FW10/all

    Untitled

    Abstract: No abstract text available
    Text: Product data sheet 3RA2815-1FW10 SOLID-STATE TIME-DELAY AUXILIARY SWITCH, OFF-DELAY WITHOUT AUXILIARY VOLTAGE RELAY 1 NC + 1 NO 24.240V AC/DC TIME RANGE 0.05.100S FOR SNAPPING ONTO THE FRONT; FOR 3RT2 CONTACTORS SCREW TERMINALS INTEGRATED VARISTOR FOR DAMPING CONTACTOR


    Original
    PDF 3RA2815-1FW10 com/WW/view/en/3RA2815-1FW10/all

    Contactor iec 947-4-1

    Abstract: J7KNA-09-01 J73KN-AM-11 IEC 947-4-1 J7KNA-09-10 J73KN-AM-22 380V 415v motor motor thermal relay VDE 0660 IEC 947-5-1 VDE 0660 DC contactor 220V
    Text: Mini Motor Contactor Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail ) • Range from 4 to 5.5 kW W ( AC 3 ,380/415V ) • 4 -main pole version ( 4 kW AC and DC coil ) • Auxiliary contacts suitable for electronic devices ( DIN


    Original
    PDF 380/415V DC24V DC48V DC110V DC125V DC24V J7KNA-09. J7KNA-12. J73KN-A. J506-E2-01 Contactor iec 947-4-1 J7KNA-09-01 J73KN-AM-11 IEC 947-4-1 J7KNA-09-10 J73KN-AM-22 380V 415v motor motor thermal relay VDE 0660 IEC 947-5-1 VDE 0660 DC contactor 220V

    Untitled

    Abstract: No abstract text available
    Text: SR106ED R C US Conforms to EN60204-1, EN954-1, VDE 0113-1 UL and C-UL listed, BG approved safety monitoring relays H SR106ED Safety Expansion Unit • Power requirements—the SR106ED will accept 24 VAC/DC, 115 VAC or 230 VAC ■ Auxiliary Output—the SR106ED has 1 N/C auxiliary


    Original
    PDF SR106ED EN60204-1, EN954-1, SR106ED SR106ED02 SR106ED03

    3TX7002

    Abstract: 3TX7002-4AB00 3TX7 siemens relay 24v
    Text: Product data sheet 3TX7002-4AB00 INPUT INTERFACE TERMINAL-TYPE OPTOCOUPLER RELAY 1NO TRANSISTOR AC/DC INPUT 24V DC OUTPUT MAX. 30V General technical details: type of voltage AC/DC Supply voltage frequency / for auxiliary and control current circuit / rated value


    Original
    PDF 3TX7002-4AB00 com/WW/view/en/3TX7002-4AB00/all 3TX7002 3TX7002-4AB00 3TX7 siemens relay 24v

    AC12

    Abstract: R0100
    Text: Electronic timer CT-MVS.12 Multifunctional with 1 c/o contact Data sheet Features ½ Rated control supply voltage 24-48 V DC, 24-240 V AC ½ Multifunction timer with 10 timing functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage,


    Original
    PDF D0201 AC12 R0100

    BG5924

    Abstract: emergency stop relay y1 y2 emergency stop relay essex relay BG 5924 schematic diagram 24v dold 7924 dold ba 7924 Switching Power Supply Schematic Diagram bg 7924
    Text: Emergency Stop Relay Type BG 5924 safemaster Features • Category 2, SIL CL3, PL e • Contacts 3 N/O 1 N/C, 4 N/O, 2 N/O • Ultra Compact 22.5 mm wide case • Internal auxiliary power supply protection with automatic reset • AC or 24V DC auxiliary power supply options


    Original
    PDF

    3phase winding data 3.7 kw to 110 kw

    Abstract: J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v
    Text: Motor Contactor J7KN Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessories • front mounted single pole additional auxiliary contacts


    Original
    PDF 380/415V) J7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v

    3phase winding data 3.7 kw to 110 kw

    Abstract: 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor
    Text: Motor Contactor Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW W • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessoires • front mounted d single pole additional auxiliary contacts


    Original
    PDF 380/415V) Conta7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor

    3TX7004-1MF00

    Abstract: 3TX70 siemens dc relay 3TX7 DC-13 siemens relay iec 3TX700
    Text: Product data sheet 3TX7004-1MF00 OUTPUT INTERFACE TWO-TIER TERMINAL-TYPE COUPLING RELAY 1N0, AC/DC 230V SCREW TERMINAL WIDTH 6.2MM General technical details: type of voltage AC/DC Supply voltage frequency / for auxiliary and control current circuit / rated value


    Original
    PDF 3TX7004-1MF00 com/WW/view/en/3TX7004-1MF00/all 3TX7004-1MF00 3TX70 siemens dc relay 3TX7 DC-13 siemens relay iec 3TX700

    timer vde 0435 manual

    Abstract: ABB vde 0435 60947-5-1 abb vde 0435 timer TIMER DIN VDE 0110 0435 vde 0435 timer vde 0110 0153S timer vde 0435 VDE 0110 vde 0435 timer manual vde 0110 timer
    Text: Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o contact Data sheet 2CDC 251 088 F0t07 Features ᕃ ᕅ ᕄ ᕆ        Rated control supply voltage 24‑240 V AC/DC Single‑function OFF‑delay timer without auxiliary voltage


    Original
    PDF F0t07 timer vde 0435 manual ABB vde 0435 60947-5-1 abb vde 0435 timer TIMER DIN VDE 0110 0435 vde 0435 timer vde 0110 0153S timer vde 0435 VDE 0110 vde 0435 timer manual vde 0110 timer

    E22575 32 amp

    Abstract: PRD11 125vdc contact resistance E22575 PRD-11AG0-240 PRD-11AH0-120 35D013 125VDC 110v dc input ballast PRD-11AG0-120
    Text: PRD series 10 to 50 Amp Heavy Duty AC or DC Power Relay File E22575 Models With All Screw Terminals File E22575 (All Others) File 15734 Features Auxiliary Snap-Action Switch • Contact ratings to 50 amps. • Magnetic blowouts available for switching DC loads.


    Original
    PDF E22575 120VAC, PRD11 13C7730 IH/3-00 E22575 32 amp 125vdc contact resistance E22575 PRD-11AG0-240 PRD-11AH0-120 35D013 125VDC 110v dc input ballast PRD-11AG0-120

    rxpdk 22h

    Abstract: RXIDk 2H 070-YA ABB RACIK 224 circuit diagram of three phase automatic changeover switch RXIDG Characteristic function el 509 RTXP 18 abb DIMENSIONS mva transformer RTXP 18
    Text: Time- and instantaneous overcurrent and earth fault line protection based on single phase elements RACIK 1MRK 509 032-BEN Page 1 Issued October 1999 Changed since February 1998 Data subject to change without notice RACIK with test switch, DC/DC converter and two auxiliary trip relays.


    Original
    PDF 032-BEN 015-BEN 002-BEN 007-BEN 003-BEN 004-BEN 001-BEN 031-UEN SE-721 rxpdk 22h RXIDk 2H 070-YA ABB RACIK 224 circuit diagram of three phase automatic changeover switch RXIDG Characteristic function el 509 RTXP 18 abb DIMENSIONS mva transformer RTXP 18

    DRM270730

    Abstract: DRL170024L 113360000
    Text: DRM Auxiliary Relay DRM 270 Relay 2 change over contacts AC/DC coil Relay Small size with high sensitivity Reasonable structure with wide usage Various types available TÜV Approvals with Output Load resistive Switching power (resistive) Contact resistance (initial)


    Original
    PDF 11-pin DRM270730 DRL170024L 113360000

    B250 C125

    Abstract: kuhnke relay kuhnke relay 24 ac KUHNKE transistor c380 c380 transistor MAGNET COIL KUHNKE kuhnke 112 C125 C380
    Text: Power Relay Power Relay P + • Specify S design in your order • 1 bridge contact for 50 A • With blow-out magnet for switching high DC loads • Auxiliary contact as control contact possible Order Code Order code P A S – 24 V DC Type of relay Power relay


    Original
    PDF

    CAD32

    Abstract: IEC 60947-5-1 ip 67 CAD-32 bs4794 DC-13 relay tesys TeSys schneider relay control relay POWER Contactor CAD 32 TH CONTACTOR
    Text: Product data sheet Characteristics CAD32SL contactor TeSys CAD-32 - 3 NO + 2 NC instantaneous - 10 A - 72 V DC Range of product TeSys D control relay Product or component type Auxiliary contactor Device short name CAD Contactor application Control circuit


    Original
    PDF CAD32SL CAD-32 DC-13 CAD32 IEC 60947-5-1 ip 67 bs4794 DC-13 relay tesys TeSys schneider relay control relay POWER Contactor CAD 32 TH CONTACTOR

    20A 125vdc relay

    Abstract: PRD-7AY0-120 1393130-7 20A ,125vdc relay C144 LR15734 6-1393127-1 3hp 150 magnetic blowout 30A 125vdc relay PRDA-11AGA-120 7-1393131-4
    Text: General Purpose Relays Industrial Relays Potter & Brumfield PRD Series Power Relay n Contact ratings to 50 amps Magnetic blowouts available for switching DC loads n Contact arrangement up to 2 form C 2CO n 1 Form C auxiliary switch available n UL class B insulation


    Original
    PDF E22575; LR15734; 600VAC 125VDC 12VDC 12VAC 20A 125vdc relay PRD-7AY0-120 1393130-7 20A ,125vdc relay C144 LR15734 6-1393127-1 3hp 150 magnetic blowout 30A 125vdc relay PRDA-11AGA-120 7-1393131-4

    Untitled

    Abstract: No abstract text available
    Text: Product data sheet 3RA2813-1FW10 SOLID-STATE TIME-DELAY AUXILIARY SWITCH, ON-DELAY RELAY 1 NC + 1 NO 24.240V AC/DC TIME RANGE 0.05.100S FOR SNAPPING ONTO THE FRONT; FOR 3RT2 CONTACTORS SCREW TERMINALS INTEGRATED VARISTOR FOR DAMPING CONTACTOR COILS General technical data:


    Original
    PDF 3RA2813-1FW10 com/WW/view/en/3RA2813-1FW10/all

    20A ,125vdc relay

    Abstract: 20A 125vdc relay MAGNETIC BALLAST PRD11AY0-120 prd-3d PRD3AJ0-120 PRD-3AJ3-24 7-1393127-5
    Text: General Purpose Relays Industrial Relays Potter & Brumfield PRD Series Power Relay n Contact ratings to 50 amps Magnetic blowouts available for switching DC loads n Contact arrangement up to 2 form C 2CO n 1 Form C auxiliary switch available n UL class B insulation


    Original
    PDF E22575; LR15734; 600VAC 125VDC 12VDC 12VAC 20A ,125vdc relay 20A 125vdc relay MAGNETIC BALLAST PRD11AY0-120 prd-3d PRD3AJ0-120 PRD-3AJ3-24 7-1393127-5

    CAD-50

    Abstract: VDE 0660 BS 4794 DC-13 CAD50JD tesys 1S120 690VDC
    Text: Product data sheet Characteristics CAD50JD contactor TeSys CAD-50 - 5 NO instantaneous - 10 A - 12 V DC Range of product TeSys D Product or component type Auxiliary contactor Device short name CAD Contactor application Control circuit Utilisation category


    Original
    PDF CAD50JD CAD-50 DC-13 VDE 0660 BS 4794 DC-13 CAD50JD tesys 1S120 690VDC

    relay 230V DC

    Abstract: relay 12 volt 24v dc relay relay 12v mA relay 5 volt 230V ac relay coil R24-PCB 230V ac relay RELAY 24V ac 12V dc DC auxiliary relay
    Text: e Product Information & News Single Gang Auxiliary Relay Part no: RIU-R24B & RIU-R12B Description Dimensions The RIU-R24B 24v dc and the RIU-R12B ( 12v dc) auxiliary relays offer a rapid and cost effective solution to applications requiring addi­ tional switching of ancillary equipment.


    OCR Scan
    PDF RIU-R24B RIU-R12B RIU-R24B availableR24-PCB) R24-BOX) RIU-R12B relay 230V DC relay 12 volt 24v dc relay relay 12v mA relay 5 volt 230V ac relay coil R24-PCB 230V ac relay RELAY 24V ac 12V dc DC auxiliary relay

    RXMH-2

    Abstract: B03-1112E RXMK1 RXME ABB 407 B03-9301E RXMH abb relay telex 48 relay BROWN BOVERI ak B03-1003E
    Text: 41 I I I I Type RXMH 2 s iH P J S Heavy-duty auxiliary relay, ASEA BR O W N BOVERI g Q Q ^ Q Q ^ g B03-1112E Data subject to. change without not ABB Relays Abstract • AC or DC voltage operated • no or nc contacts • Maximum power consumption: dc 4.6 W


    OCR Scan
    PDF B03-1112E 067-AD B03-1003E B03-9301E B03-9382E S-721 RXMH-2 RXMK1 RXME ABB 407 RXMH abb relay telex 48 relay BROWN BOVERI ak