DIN 46228 PART 4 Search Results
DIN 46228 PART 4 Result Highlights (4)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
LM4040AIM3-5.0 |
![]() |
100-ppm/°C precision micropower shunt voltage reference 3-SOT-23 |
![]() |
||
LM4040CIM3-10.0 |
![]() |
100-ppm/°C precision micropower shunt voltage reference 3-SOT-23 |
![]() |
||
LM4040DIM3-5.0 |
![]() |
100-ppm/°C precision micropower shunt voltage reference 3-SOT-23 |
![]() |
||
LM4040AIZ-2.5/NOPB |
![]() |
100-ppm/°C precision micropower shunt voltage reference 3-TO-92 |
![]() |
![]() |
DIN 46228 PART 4 Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
Contextual Info: Aderendhulsen Terminal ends DIN 46228 Teil 1 und 3 und ahnliche Ausfuhrungen DIN 46228 part 1 and 3 and similar types Typ 1 Typ 3 Typ 2 dl Typ Nennquerschnitt qmm 1 0,75 -1 DIN NenngroBe 46228 D1-7 a1 di 0,6-1 1 46228 0,75 -1 46228 1,5 46228 1,5 D1-7 L1 |
OCR Scan |
A6-10 A6-12 A10-12 | |
vogt 94
Abstract: vogt* 2.1 450507.6 CH-4654 vogt vogt ag DIN 46228
|
Original |
CH-4654 vogt 94 vogt* 2.1 450507.6 vogt vogt ag DIN 46228 | |
Contextual Info: Printview: Ferrule; sleeve for 0.75 mm² / awg 20; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part 4/09.90 - Item No.: 216-242 . Ferrule; sleeve for 0.75 mm² / awg 20; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part |
Original |
||
Contextual Info: Printview: Ferrule; sleeve for 6 mm² / awg 10; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part 4/09.90 - Item No.: 216-208 . Ferrule; sleeve for 6 mm² / awg 10; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part |
Original |
||
DIN-46228 PART 4Contextual Info: Printview: Ferrule; sleeve for 4 mm² / awg 12; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part 4/09.90 - Item No.: 216-267 . Ferrule; sleeve for 4 mm² / awg 12; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part |
Original |
||
DIN-46228 PART 4Contextual Info: Printview: Ferrule; sleeve for 1.5 mm² / awg 16; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part 4/09.90 - Item No.: 216-244 . Ferrule; sleeve for 1.5 mm² / awg 16; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part |
Original |
||
Contextual Info: Printview: Ferrule; sleeve for 16 mm² / awg 6; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part 4/09.90 - Item No.: 216-210 . Ferrule; sleeve for 16 mm² / awg 6; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part |
Original |
||
Contextual Info: Printview: Ferrule; sleeve for 2.5 mm² / awg 14; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part 4/09.90 - Item No.: 216-266 . Ferrule; sleeve for 2.5 mm² / awg 14; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part |
Original |
||
Contextual Info: Printview: Ferrule; sleeve for 1 mm² / awg 18; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part 4/09.90 - Item No.: 216-243 . Ferrule; sleeve for 1 mm² / awg 18; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part |
Original |
||
Contextual Info: Printview: Ferrule; sleeve for 0.5 mm² / awg 22; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part 4/09.90 - Item No.: 216-241 . Ferrule; sleeve for 0.5 mm² / awg 22; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part |
Original |
||
Contextual Info: Printview: Ferrule; sleeve for 2.5 mm² / awg 14; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part 4/09.90 - Item No.: 216-246 . Ferrule; sleeve for 2.5 mm² / awg 14; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part |
Original |
||
Contextual Info: Printview: Ferrule; sleeve for 1 mm² / awg 18; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part 4/09.90 - Item No.: 216-263 . Ferrule; sleeve for 1 mm² / awg 18; insulated; electro-tin plated; electrolytic copper; gastight crimped; acc. to DIN 46228, Part |
Original |
||
11182250
Abstract: VICE70150 118201 1182050 TRAP24-10 112711200 DIN-46228 PART 4
|
Original |
VICE70150 11182250 VICE70150 118201 1182050 TRAP24-10 112711200 DIN-46228 PART 4 | |
Contextual Info: American Electrical | Wire Ferrules Slide Box Page 1 of 1 Wire Ferrule Slide Box DIN 46228 Part 4 DIN Insulated Wire Ferrules Insulated Wire Ferrules Twin Wire Ferrules Size mm2 AWG Barrel Length mm 0.50 22 8 0.75 20 1.00 W Color Code DIN Part Number Quantity |
Original |
1617050T 1627050T | |
|
|||
13142060
Abstract: DIN-46228 PART 4
|
Original |
SQ28-10 TRAP24-10 13142060 DIN-46228 PART 4 | |
VICE70150Contextual Info: American Electrical | Non-Insulated Wire Ferrules Non-Insulated Wire Ferrules DIN 46228 Part 1 Size mm2 0.25 AWG 2426 2224 Part Number Pieces per bag Dimensions mm L D1 D2 Recommended Crimping Tools S Recommended Crimping Tools |
Original |
SQ28-10 TRAP24-10 VICE70150 | |
Contextual Info: WIRE FERL UNINSUL Non-Insulated Wire Ferrules Cat No: 74/18VZ UPC No: 783310050193 Description • • • For terminating stranded wire into terminal blocks Electrolytic copper and tin plating provide maximum conductivity and low contact resistance Meets DIN 46228, part 1, 0.5 - 50 mm2 |
Original |
74/18VZ K32GL, K36GL, K30GL, | |
Contextual Info: WIRE FERL UNINSUL Non-Insulated Wire Ferrules Cat No: 80/18VZ UPC No: 783310050490 Description • • • For terminating stranded wire into terminal blocks Electrolytic copper and tin plating provide maximum conductivity and low contact resistance Meets DIN 46228, part 1, 0.5 - 50 mm2 |
Original |
80/18VZ K28GL, K29GL | |
Contextual Info: WIRE FERL UNINSUL Non-Insulated Wire Ferrules Cat No: 72/12VZ UPC No: 783310050070 Description • • • For terminating stranded wire into terminal blocks Electrolytic copper and tin plating provide maximum conductivity and low contact resistance Meets DIN 46228, part 1, 0.5 - 50 mm2 |
Original |
72/12VZ K32GL, K36GL, K30GL, | |
10VZ/X/
Abstract: 71/10VZ/
|
Original |
71/10VZ K32GL, K36GL, K30GL, 10VZ/X/ 71/10VZ/ | |
Contextual Info: WIRE FERL UNINSUL Non-Insulated Wire Ferrules Cat No: 77/15VZ UPC No: 783310050339 Description • • • For terminating stranded wire into terminal blocks Electrolytic copper and tin plating provide maximum conductivity and low contact resistance Meets DIN 46228, part 1, 0.5 - 50 mm2 |
Original |
77/15VZ K28GL, K34GL, | |
DIN-46228 PART 4
Abstract: TSSC002 DIN 46228 part 4 gwe-6
|
Original |
FWE4-10 GWE10-12 GWE16-12 GWE25-16 GWE35-16 GWE50-20 TSSC002 DIN-46228 PART 4 DIN 46228 part 4 gwe-6 | |
Contextual Info: WIRE FERL UNINSUL Non-Insulated Wire Ferrules Cat No: 83/30VZ UPC No: 783310050605 Description • • • For terminating stranded wire into terminal blocks Electrolytic copper and tin plating provide maximum conductivity and low contact resistance Meets DIN 46228, part 1, 0.5 - 50 mm2 |
Original |
83/30VZ 22/120Dies | |
Contextual Info: WIRE FERL UNINSUL Non-Insulated Wire Ferrules Cat No: 79/15VZ UPC No: 783310050445 Description • • • For terminating stranded wire into terminal blocks Electrolytic copper and tin plating provide maximum conductivity and low contact resistance Meets DIN 46228, part 1, 0.5 - 50 mm2 |
Original |
79/15VZ K28GL |