43880 enclosure
Abstract: 43880 din 43880 lightning event counter HIT-LEC-A AC110-240V AC110 Alternative
Text: Lightning Event Counter Prosurge Electronics TYPE: HIT-LEC-A Lightning Event Count Lightning event counter is used for testing the lightning event in a certain area. Counting accurately Sensitive response Stable capability, strongly anti-jamming.
|
Original
|
PDF
|
AC110
43880 enclosure
43880
din 43880
lightning event counter
HIT-LEC-A
AC110-240V
Alternative
|
"Overflow detection"
Abstract: No abstract text available
Text: APPLICATION NOTE H8/300H SLP Series Asynchronous Event Counter Operation Using the 8-Bit Mode Introduction The asynchronous event counter is used in the 8-bit mode to invert port output in fixed cycles. 2-MHz event input is performed at the asynchronous event input L AEVL pin, and P40 pin output is inverted every 8-bit event counter L
|
Original
|
PDF
|
H8/300H
H8/38076R
REJ06B0427-0100/Rev
"Overflow detection"
|
MSV30262
Abstract: No abstract text available
Text: APPLICATION NOTE M16C/26 Using the M16C/26 Timer in Event Counter Mode 1.0 Abstract Event counters are useful in automated packaging lines, tachometers, and mechanical equipment monitoring. The event counters on the M16C/26 can be configured to interrupt on a single event as well, creating additional
|
Original
|
PDF
|
M16C/26
M16C/26
M30262
16-bit
M16C/60
10-bit
MSV30262
|
Untitled
Abstract: No abstract text available
Text: APPLICATION NOTE M16C/62 Using the M16C/62 Timer in Event Counter Mode 1.0 Abstract Event counters are useful in automated packaging lines, tachometers, and mechanical equipment monitoring. Also, the event counters on the M16C/62 can be configured to interrupt on a single event, adding to the interrupt
|
Original
|
PDF
|
M16C/62
M16C/62
16-bit
10-bit
|
ech4
Abstract: "Overflow detection"
Text: APPLICATION NOTE H8/300H SLP Series Asynchronous Event Counter Operation Using the 16-Bit Mode Introduction The asynchronous event counter is used in the 16-bit mode to invert port output in fixed cycles. 2-MHz event input is performed at the asynchronous event input L AEVL pin, and P40 pin output is inverted every overflow cycle (32.768
|
Original
|
PDF
|
H8/300H
16-Bit
H8/38076R
REJ06B0428-0100/Rev
ech4
"Overflow detection"
|
h001a
Abstract: No abstract text available
Text: APPLICATION NOTE H8/300L SLP Series Measuring Pulse Frequency by Event Counting Introduction Using the Timer C 8-bit event counter function, this function measures the pulse frequency input through Timer C Event Input Pin TMIC . Target Device H8/38024 Contents
|
Original
|
PDF
|
H8/300L
H8/38024
REJ06B0238-0100Z/Rev
h001a
|
DDS232H
Abstract: MIL-M-7793 M7793 electronic rolling display RS232 TTL hour meter DDS232C L-3 Communications 779-3 M7793/13-1
Text: Elapsed Time Indicators & Event Counters The Dynatime Digital Series RS232 PC Board Mount Hour Meters & Event Counters Model DDS232H – Hour Meter Model DDS232C – Event Counter FEATURES Mechanical Specifications • Monitors your system usage • RS232/TTL output
|
Original
|
PDF
|
RS232
DDS232H
DDS232C
RS232/TTL
RS232/TTL
MIL-M-7793/13
DDS232H
military-1751
06-S-1343
MIL-M-7793
M7793
electronic rolling display
RS232 TTL
hour meter
DDS232C
L-3 Communications
779-3
M7793/13-1
|
M7793
Abstract: MIL-M-7793 DDS100 DDS101 dynatime M7793/13-1 S1341 MILM-7793
Text: Elapsed Time Indicators & Event Counters The Dynatime Digital Series Solid State, PC Board Mount Hour Meters & Event Counters FEATURES • Monitors your system usage Model DDS100: Hour Meter Model DDS101: Event Counter • PCB Mount • Non-Volatile Memory
|
Original
|
PDF
|
DDS100:
DDS101:
MIL-M-7793/13
RS232/TTL
DDS100
06-S-1341
M7793
MIL-M-7793
DDS101
dynatime
M7793/13-1
S1341
MILM-7793
|
Untitled
Abstract: No abstract text available
Text: APPLICATION NOTE H8/300L Super Low Power Series Measuring Pulse Frequency by Event Counting Introduction Using the Timer C 8-bit event counter function, this function measures the pulse frequency input through Timer C Event Input Pin TMIC . Target Device
|
Original
|
PDF
|
H8/300L
H8/38024
REJ06B0238-0200/Rev
|
3A97
Abstract: circuit diagram of event counter
Text: APPLICATION NOTE H8/300H SLP Series Duty Pulse Output Using AEC Event Counter PWM Output Function Introduction Duty pulses are output using the event counter PWM output function of the asynchronous event counter AEC . Target Device H8/38076R Contents 1. Specifications . 2
|
Original
|
PDF
|
H8/300H
H8/38076R
REJ06B0433-0100/Rev
3A97
circuit diagram of event counter
|
FFF067
Abstract: No abstract text available
Text: APPLICATION NOTE H8/300H Super Low Power Series Pulse-Frequency Measurement Using the Event-Counter Function of Timer C Introduction Event counter function of timer C is used to measure pulse-frequency input from timer C event input TMIC pin. Target Device
|
Original
|
PDF
|
H8/300H
H8/38099
REJ06B0637-0100/Rev
FFF067
|
DSP56002
Abstract: No abstract text available
Text: SECTION 7 DSP56002 TIMER AND EVENT COUNTER MOTOROLA 7-1 SECTION CONTENTS 7.1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 7.2 TIMER/EVENT COUNTER BLOCK DIAGRAM . . . . . . . . . . . . . . . . . . . . . . 7-3
|
Original
|
PDF
|
DSP56002
0002A
|
IR2110 equivalent
Abstract: ac control using ir2110 and mosfet IR2110 application note IS-2100ARH IS2100ARH ac control using ir2110 IR2110 HIP2500 AN IR2110 IS-2100
Text: Single Event Testing of the IS-2100ARH Half Bridge Driver Introduction The intense heavy ion environment encountered in space applications can cause a variety of transient and destructive effects in analog circuits, including single-event latchup SEL , single-event upset (SEU) and single-event burnout (SEB). These effects can lead to
|
Original
|
PDF
|
IS-2100ARH
IS-2100ASRH
90MeV/mg/cm2,
4x106
42x10-4
3x10-4
IR2110 equivalent
ac control using ir2110 and mosfet
IR2110 application note
IS2100ARH
ac control using ir2110
IR2110
HIP2500
AN IR2110
IS-2100
|
H8/3664
Abstract: Counter page counter
Text: APPLICATION NOTE H8/300H Tiny Series Using Timer V 8-Bit Event Counter Function to Measure Input Pulses Introduction Timer V's 8-bit event counter function is used to count the number of rising edges of the pulses input from the timer V event input pin TMCIV .
|
Original
|
PDF
|
H8/300H
H8/3664
REJ06B0087-0100Z/Rev
H8/3664
Counter
page counter
|
|
Untitled
Abstract: No abstract text available
Text: APPLICATION NOTE H8/300H Tiny Series Using Timer V 8-Bit Event Counter Function to Measure Input Pulses Introduction Timer V's 8-bit event counter function is used to count the number of rising edges of the pulses input from the timer V event input pin TMCIV .
|
Original
|
PDF
|
H8/300H
H8/3664
REJ06B0087-0100Z/Rev
|
counter
Abstract: COUNTER LED HT47R20A-1
Text: Using the Timer/Event Counter in the HT47R20A-1 Using the Timer/Event Counter in the HT47R20A-1 :HA0031E D/N Introduction The following notes introduce the usage of the HT47R20A-1 Timer/Event Counter. The HT47R20A-1 has a 16 bit continuous counting timer/counter known as TMRAH,
|
Original
|
PDF
|
HT47R20A-1
A0031E
HT47R20A-1
counter
COUNTER LED
|
Untitled
Abstract: No abstract text available
Text: APPLICATION NOTE H8/38076R Measuring Number of Input Pulses Using 16-Bit Event Counter Function of Timer F Introduction The 16-bit event counter function of timer F is used to count the rising edges of pulses input to the timer F event input TMIF pin. Target Device
|
Original
|
PDF
|
H8/38076R
16-Bit
REJ06B0526-0100/Rev
|
DSP56002
Abstract: No abstract text available
Text: SECTION 8 TIMER/EVENT COUNTER MOTOROLA 8-1 SECTION CONTENTS Paragraph Number Section Page Number 8.1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3 8.2 TIMER/EVENT COUNTER BLOCK DIAGRAM . . . . . . . . . . . . . . . . . . . . . . 8-3
|
Original
|
PDF
|
0002A
DSP56002
|
ISL72991
Abstract: ISL72991RH K500
Text: Single Event Effects Testing of the ISL72991RH Adjustable Voltage Regulator June 2002 Introduction The intense, heavy ion environment encountered in space applications can cause a variety of effects in electronic circuitry, including single event transient SET , single event latchup
|
Original
|
PDF
|
ISL72991RH
500mA;
ISL72991
K500
|
Daiwa DT-26S
Abstract: No abstract text available
Text: DS1678 Real-Time Event Recorder www.maxim-ic.com GENERAL DESCRIPTION FEATURES The DS1678 real-time clock RTC event recorder records the time and date of a nonperiodic, asynchronous event each time the INT pin is activated. The device records the seconds, minutes,
|
Original
|
PDF
|
DS1678
DS1678
16-bit
Daiwa DT-26S
|
mip 836
Abstract: mip 836 ic MIP 284 DS1678S equivalent DS1678 DS1678S mip 0245 MIP 2f
Text: DS1678 Real-Time Event Recorder www.maxim-ic.com GENERAL DESCRIPTION FEATURES The DS1678 real-time clock RTC event recorder records the time and date of a nonperiodic, asynchronous event each time the INT pin is activated. The device records the seconds, minutes,
|
Original
|
PDF
|
DS1678
DS1678
16bit
56-G5005-000
56-G4010-001
mip 836
mip 836 ic
MIP 284
DS1678S equivalent
DS1678S
mip 0245
MIP 2f
|
mip 836
Abstract: No abstract text available
Text: DS1678 Real-Time Event Recorder www.maxim-ic.com GENERAL DESCRIPTION FEATURES The DS1678 real-time clock RTC event recorder records the time and date of a nonperiodic, asynchronous event each time the INT pin is activated. The device records the seconds, minutes,
|
Original
|
PDF
|
DS1678
DS1678
16bit
mip 836
|
mip 836
Abstract: DS1678 DS1678S S1678 mip 0245 MIP 2f
Text: DS1678 Real-Time Event Recorder www.maxim-ic.com GENERAL DESCRIPTION FEATURES The DS1678 real-time clock RTC event recorder records the time and date of a nonperiodic, asynchronous event each time the INT pin is activated. The device records the seconds, minutes,
|
Original
|
PDF
|
DS1678
DS1678
16bit
mip 836
DS1678S
S1678
mip 0245
MIP 2f
|
9v to 5v voltage regulator
Abstract: Adjustable Positive Voltage Regulator 50v HS-117RH 5v to 9v voltage regulator capacitor 22uf HS-117 data sheet capacitor 22uF gold capacitor KRYPTON K500
Text: Single Event Effects Testing of the HS-117RH Adjustable Voltage Regulator June 2002 Introduction The intense, heavy ion environment encountered in space applications can cause a variety of effects in electronic circuitry, including single event transient SET , single event latchup
|
Original
|
PDF
|
HS-117RH
500mA;
9v to 5v voltage regulator
Adjustable Positive Voltage Regulator 50v
5v to 9v voltage regulator
capacitor 22uf
HS-117
data sheet capacitor 22uF
gold capacitor
KRYPTON
K500
|