Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    FLUX METER Search Results

    FLUX METER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CMZ12A
    Toshiba Electronic Devices & Storage Corporation Zener Diode, 12 V, M-FLAT Visit Toshiba Electronic Devices & Storage Corporation
    CMZ16A
    Toshiba Electronic Devices & Storage Corporation Zener Diode, 16 V, M-FLAT Visit Toshiba Electronic Devices & Storage Corporation
    CMZ24A
    Toshiba Electronic Devices & Storage Corporation Zener Diode, 24 V, M-FLAT Visit Toshiba Electronic Devices & Storage Corporation
    CMZ36A
    Toshiba Electronic Devices & Storage Corporation Zener Diode, 36 V, M-FLAT Visit Toshiba Electronic Devices & Storage Corporation
    CMZ20A
    Toshiba Electronic Devices & Storage Corporation Zener Diode, 20 V, M-FLAT Visit Toshiba Electronic Devices & Storage Corporation

    FLUX METER Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    siemens hall ferrite

    Contextual Info: SIEMENS Magnetics 1.1 Magnetic units and definitions 1.1.1 Magnetic flux <I> The magnetic flux <1> results as a product of electric voltage and time. The S.l. unit of magnetic flux is the Weber Wb or the Volt-second (Vs). If the magnetic flux <J>changes


    OCR Scan
    PDF

    relative magnet permeability

    Abstract: iron bh curve magnetic flow meter magnet permeability application of b-h curve induction constant magnetization of a permanent magnet BH Curve
    Contextual Info: Silicon Hall-Effect Sensors 6.2 Magnetic Units and Definitions Magnetic Flux Φ The magnetic flux Φ results as a product of electric voltage and time. The S.I. unit of magnetic flux is the Weber Wb or the Volt-second (Vs). If the magnetic flux Φ changes


    Original
    PDF

    relative magnet permeability

    Abstract: iron bh curve magnet permeability square loop toroid application of b-h curve magnetic flow meter
    Contextual Info: Silicon Hall-Effect Sensors 6.2 Magnetic Units and Definitions Magnetic Flux Φ The magnetic flux Φ results as a product of electric voltage and time. The S.I. unit of magnetic flux is the Weber Wb or the Volt-second (Vs). If the magnetic flux Φ changes


    Original
    PDF

    lzn2

    Abstract: RELAY OMRON LZN g5y-154p RELAY OMRON LZN2 OMRON lzn2 eac reed relay omron type LZN coil eddy current 220 ac INVERTER without transformer for iron weld Matsua Miniature Relay s4 5v
    Contextual Info: Introduction Introduction Back Technical Information Relay Classification Model Mounting Discrete Enclosure Ratings Features Unsealed Designed for manual soldering. G2R Flux protection Designed inhibits flux intrusion into the casing from the terminals during soldering.


    Original
    PDF

    2 coil electromagnetic induction

    Abstract: induction heating Microspire flux
    Contextual Info: 100 Engineering Services Electromagnetic Characteristics of Magnetics Our Engineers use advanced finite-element simulation software such as Flux 2D and Flux 3D to model, analyse and optimise the electromagnetic behaviour of existing or to be designed magnetics.


    Original
    PDF

    Omron H3BA

    Abstract: RELAY OMRON LZN 203 G5LE-1-VD 24VDC 10A 250VAC 5A 250VAC OMRON iec255 10A 110VAC h3ba omron timer h3ba omron g5lb -1-25 omron h3ba timer omron relay H3BA how to connect omron relay H3BA
    Contextual Info: Technical Information – Relays • Relay Classification Model G4W Discrete Enclosure Ratings Features Unsealed Designed for manual soldering G2R Flux protection Design inhibits flux intrusion into the casing fro the terminals during soldering. G6A Fully sealed


    Original
    PDF

    OMRON lzn2

    Abstract: RELAY OMRON LZN2 RELAY OMRON LZN G5Y-154P lzn2 OMRON RELAY LZN omron type LZN eac reed relay omron relay lzn2 Omron LZN
    Contextual Info: Omron A5 Catalogue 2007 1-282 11/9/06 10:16 am Page 10 Technical Information – Relays • Relay Classification Model G4W Discrete Enclosure Ratings Features Unsealed Designed for manual soldering G2R Flux protection Design inhibits flux intrusion into the casing fro


    Original
    PDF

    LED wavelength 510

    Contextual Info: SUPER FLUX LED BTF-08GMCS-XX-X Package Dimension Product Features ƒ ƒ ƒ ƒ ƒ ƒ ƒ Ultra Bright Emerald Green Color High Light Output Flat head Super Flux Package Water Clear Lens Highly Reliable IC Compatible Leads without Stand Off Applications ƒ ƒ


    Original
    BTF-08GMCS-XX-X 063inch) LED wavelength 510 PDF

    electricity meters

    Contextual Info: SUPER FLUX LED BTF-08BLCS-XX-X Package Dimension Product Features ƒ ƒ ƒ ƒ ƒ ƒ ƒ Ultra Bright Blue Color High Light Output Flat head Super Flux Package Water Clear Lens Highly Reliable IC Compatible Leads without Stand Off Applications ƒ ƒ ƒ ƒ ƒ


    Original
    BTF-08BLCS-XX-X 063inch) electricity meters PDF

    LED wavelength 510

    Abstract: LED wavelength 520 high light
    Contextual Info: SUPER FLUX LED BTF-57GMCS-XX-X Package Dimension Product Features ƒ ƒ ƒ ƒ ƒ ƒ ƒ Ultra Bright Emerald Green Color High Light Output 5mm Super Flux Package Water Clear Lens Highly Reliable IC Compatible Leads without Stand Off Applications ƒ ƒ ƒ ƒ


    Original
    BTF-57GMCS-XX-X 063inch) LED wavelength 510 LED wavelength 520 high light PDF

    Contextual Info: SUPER FLUX LED BTF-37AMCS-XX-X Package Dimension Product Features ƒ ƒ ƒ ƒ ƒ ƒ ƒ Ultra Bright Amber Color High Light Output 3mm Super Flux Package Water Clear Lens Highly Reliable IC Compatible Leads with Stand Off Applications ƒ ƒ ƒ ƒ ƒ Outdoor Sign Board


    Original
    BTF-37AMCS-XX-X 063inch) PDF

    Contextual Info: LED CHAPTER 08 1 Features 2 Structure 3 Operating principle 4 Characteristics 4-1 4-2 4-3 4-4 4-5 4-6 4-7 4-8 Radiant flux total light amount Radiant intensity Irradiance Forward current vs. forward voltage characteristics Radiant flux vs. forward current characteristics


    Original
    KLEDB0373EB KLEDB0380EA PDF

    IR010

    Contextual Info: SUPER FLUX LED BTF-57BLCS-XX-X Package Dimension Product Features ƒ ƒ ƒ ƒ ƒ ƒ ƒ Ultra Bright Blue Color High Light Output 5mm Super Flux Package Water Clear Lens Highly Reliable IC Compatible Leads with Stand Off Applications ƒ ƒ ƒ ƒ ƒ Outdoor Sign Board


    Original
    BTF-57BLCS-XX-X 063inch) J4Y-22Z IR010 PDF

    P 620

    Abstract: 37NR
    Contextual Info: SUPER FLUX LED BTF-37NRCS-XX-X Package Dimension Product Features ƒ ƒ ƒ ƒ ƒ ƒ ƒ Ultra Bright Normal Red Color High Light Output 3mm Super Flux Package Water Clear Lens Highly Reliable IC Compatible Leads with Stand Off Applications ƒ ƒ ƒ ƒ ƒ Outdoor Sign Board


    Original
    BTF-37NRCS-XX-X 063inch) P 620 37NR PDF

    Contextual Info: SUPER FLUX LED BTF-37YECS-XX-X Package Dimension Product Features ƒ ƒ ƒ ƒ ƒ ƒ ƒ Ultra Bright Yellow Color High Light Output 3mm Super Flux Package Water Clear Lens Highly Reliable IC Compatible Leads with Stand Off Applications ƒ ƒ ƒ ƒ ƒ Outdoor Sign Board


    Original
    BTF-37YECS-XX-X 063inch) PDF

    Contextual Info: SUPER FLUX LED BTF-57AMCS-XX-X Package Dimension Product Features ƒ ƒ ƒ ƒ ƒ ƒ ƒ Ultra Bright Amber Color High Light Output 5mm Super Flux Package Water Clear Lens Highly Reliable IC Compatible Leads with Stand Off Applications ƒ ƒ ƒ ƒ ƒ Outdoor Sign Board


    Original
    BTF-57AMCS-XX-X 063inch) PDF

    Contextual Info: SUPER FLUX LED BTF-37BLCS-XX-X Package Dimension Product Features ƒ ƒ ƒ ƒ ƒ ƒ ƒ Ultra Bright Blue Color High Light Output 3mm Super Flux Package Water Clear Lens Highly Reliable IC Compatible Leads with Stand Off Applications ƒ ƒ ƒ ƒ ƒ Outdoor Sign Board


    Original
    BTF-37BLCS-XX-X 063inch) PDF

    Contextual Info: SUPER FLUX LED BTF-57NRCS-XX-X Package Dimension Product Features ƒ ƒ ƒ ƒ ƒ ƒ ƒ Ultra Bright Normal Red Color High Light Output 5mm Super Flux Package Water Clear Lens Highly Reliable IC Compatible Leads with Stand Off Applications ƒ ƒ ƒ ƒ ƒ Outdoor Sign Board


    Original
    BTF-57NRCS-XX-X 063inch) PDF

    gaussmeter

    Abstract: gaussmeter probe HS-AGB5-4805 MNT-4E04-VG HS-STF99-0402 SAD58-1904 MMA-2508-VH HS-TB51 HS-STM99-0402 MNT-4E04-VH
    Contextual Info: Gaussmeter Probes for FH 26, FH 27, FH 46, FH 47 Description Our gaussmeter probes are designed to meet the electrical and mechanical requirements of virtually any application. Models are available for transverse lines of flux moving perpendicular through the probe tip and axial (magnetic lines of flux moving through the length of the probe) measurements. Cryogeni, magnaprobe and multi-axis probes are also available.


    Original
    HS-AGB5-4820 D-50996 gaussmeter gaussmeter probe HS-AGB5-4805 MNT-4E04-VG HS-STF99-0402 SAD58-1904 MMA-2508-VH HS-TB51 HS-STM99-0402 MNT-4E04-VH PDF

    Piezo speaker crossover

    Abstract: Piezo tweeter tweeter piezo piezo transformer driver 40 hz frequency power FERRITE TRANSFORMER design tweeter TS-43A TS28A 8C10CO TS-28A
    Contextual Info: This dynamic coaxial speaker for Speaker Size Power Rating Frequency Response Resonant Frequency Nominal Impedance Magnet type and weight Flux Density Sensitivity 1 watt 1 meter Depth (less transformer) Dispersion (half space @ 2 KHz - 6 dB down point Features


    Original
    TS-14B TS-18, TS-41A, TS-43A, TS-33A, TS-44A TS-26A TS-37B, TS-28A, TS-50 Piezo speaker crossover Piezo tweeter tweeter piezo piezo transformer driver 40 hz frequency power FERRITE TRANSFORMER design tweeter TS-43A TS28A 8C10CO TS-28A PDF

    g5y-154p

    Abstract: MBB mini relay 5V 1A DPDT RELAY ic type omron relay pcb relay cross reference PE Relay relay for inverter trigger detracted moving iron repulsion type system dual latching relay ic
    Contextual Info: Electromechanical Relays Technical Information Relay Classification Model LY Mounting Discrete G2R G6A G6S Surface mounting Enclosure Ratings Features Unsealed Designed for manual soldering Semi-sealed Design inhibits flux intrusion into the casing at the terminals


    Original
    X301-E-1a g5y-154p MBB mini relay 5V 1A DPDT RELAY ic type omron relay pcb relay cross reference PE Relay relay for inverter trigger detracted moving iron repulsion type system dual latching relay ic PDF

    Omron

    Abstract: Electromechanical Relays G5Y-154P full automatic Washing machines circuit diagram omron 11 pin 24 Volt DC relay current controlled lead acid battery charging cir 5V 1A DPDT RELAY ic type moving iron repulsion type system OMRON latching relay driver rectifier diode pressfit
    Contextual Info: Electromechanical Relays Technical Information Relay Classification Model LY Mounting Discrete G2R G6A G6S Surface mounting Enclosure Ratings Features Unsealed Designed for manual soldering Semi-sealed Design inhibits flux intrusion into the casing at the terminals


    Original
    X301-E-1 Omron Electromechanical Relays G5Y-154P full automatic Washing machines circuit diagram omron 11 pin 24 Volt DC relay current controlled lead acid battery charging cir 5V 1A DPDT RELAY ic type moving iron repulsion type system OMRON latching relay driver rectifier diode pressfit PDF

    smps transformers epcos

    Abstract: ETD FERRITE transformer ring ferrite cores Flux Density
    Contextual Info: Direct Link 1063 Products & Technologies Ferrites February 2007 New materials for power applications EPCOS has developed two new ferrite materials whose improved properties make them suitable for the power range typical of SMPS and current meters. N95 is distinguished by a high flux density of 525 mT at 25


    Original
    applicati10 smps transformers epcos ETD FERRITE transformer ring ferrite cores Flux Density PDF

    L945VEC-65D

    Contextual Info: American Opto Plus LED L-945VEC-65D MAIN FEATURES High flux output HIGH POWER LED LAMP –WATER Wide viewing angle Low thermal resistance CLEAR High power consumption AlInGaP PACKAGE DIMENSIONS SELECTION GUIDE AND APPLICATION INFORMATION ( RATINGS AT 25 AMBIENT )


    Original
    L-945VEC-65D L945VEC-65D 1/16inch) L945VEC-65D PDF