GFCI BREAKER Search Results
GFCI BREAKER Result Highlights (3)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
LM74900QRGERQ1 |
![]() |
Automotive ideal diode with circuit breaker, under- and overvoltage protection with fault output 24-VQFN -40 to 125 |
![]() |
||
LM74930QRGERQ1 |
![]() |
Automotive 3-V to 65-V surge stopper with circuit breaker and overvoltage protection 24-VQFN -40 to 125 |
![]() |
||
LM74910QRGERQ1 |
![]() |
Automotive ideal diode with circuit breaker, 200-kHz ACS and under- and overvoltage protection 24-VQFN -40 to 125 |
![]() |
GFCI BREAKER Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
Contextual Info: TESTER-GFI & CIRCUIT CALIB GFCI and Circuit Tester Cat No: 5708-C UPC No: 783310076407 Description • • • • Allows instant testing of GFCI receptacles or GFCI circuit breaker protected circuits Checks 120VAC grounded outlets for correct/incorrect wiring |
Original |
5708-C 120VAC | |
Airpax 3 pole 100 amp ELCI breaker
Abstract: shunt trip breaker Airpax ground fault circuit interrupter schematic diagram ac circuit breaker Airpax 3 pole 100 amp breaker SAE J1171 LELK1 airpax circuit breaker voltage ratings main circuit breaker GFCI schematic
|
Original |
240VAC CFR1926 LEL12-1REC5-37583-30-G1-V LELK12-1REC5-37583-50-G1-V LEL12-1REC5-37583-30-G2-V LEL12-1REC5-37583-50-G2-V LEL121-1REC5-37275-30-G1-V LELK121-1REC5-37275-50-G1-V Airpax 3 pole 100 amp ELCI breaker shunt trip breaker Airpax ground fault circuit interrupter schematic diagram ac circuit breaker Airpax 3 pole 100 amp breaker SAE J1171 LELK1 airpax circuit breaker voltage ratings main circuit breaker GFCI schematic | |
Airpax
Abstract: Airpax LEL UL 943 shunt trip breaker GFCI schematic airpax temperature limit switch airpax circuit breaker PGFM-111B CFR1926 shunt trip
|
Original |
240VAC CFR1926 Airpax Airpax LEL UL 943 shunt trip breaker GFCI schematic airpax temperature limit switch airpax circuit breaker PGFM-111B shunt trip | |
Contextual Info: 1113/25 Circuit Breaker GFCI Rocker Actuated Ground Fault Circuit Breaker Environmental Sealing Boot Shown is Carling Technologies PB Circuit Breaker GFCI FEATURES and BENEFITS • Environmentally protects to IP66/68 ingress rating • RUBRGLAS silicone rubber boot prevents |
Original |
IP66/68 MIL-DTL-5423 MIL-DTL-5423 | |
Contextual Info: Product Overview NCS37000: Single CT GFCI Signal Processor For complete documentation, see the data sheet Product Description The NCS37000 is a signal processor for GFCI applications. The device integrates a flexible power supply including both shunt and |
Original |
NCS37000: NCS37000 NCS37000MNG NCS37000MNRG QFN-16 QFN-16 | |
SCHEMATIC circuit scr oscillator
Abstract: GFCI schematic
|
Original |
NCS37000 UL943 QFN16 TSSOP-20 NCS37000/D SCHEMATIC circuit scr oscillator GFCI schematic | |
Contextual Info: NCS37000 Product Preview Ground Fault Circuit Interrupter GFCI Description The NCS37000 is a fully UL943 compliant signal processor for GFCI applications. The device integrates a flexible power supply (including both shunt and LDO regulators), differential fault, and |
Original |
NCS37000 NCS37000 UL943 QFN16 NCS37000/D | |
Contextual Info: NCS37010 Self Test With Lockout Ground Fault Circuit Interrupter GFCI The NCS37010 is a fully UL943 compliant signal processor for GFCI applications with self test and lockout. The device integrates a flexible power supply (including both shunt and LDO regulators), |
Original |
NCS37010 NCS37010 UL943 NCS37010/D | |
Contextual Info: NCS37010 Self Test With Lockout Ground Fault Circuit Interrupter GFCI The NCS37010 is a fully UL943 compliant signal processor for GFCI applications with self test and lockout. The device integrates a flexible power supply (including both shunt and LDO regulators), |
Original |
NCS37010 UL943 NCS37010/D | |
Contextual Info: PowerVerter Plus 3000W Heavy-Duty Inverter with 4 GFCI Outlets MODEL NUMBER: PV3000GFCI Highlights 12V DC input; 120V AC output; 4 outlets GFCI protected NEMA 5-15R 3000 watts continuous output; 6000 watts peak output (instantaneous) Quiet electricity for TVs, DVD |
Original |
PV3000GFCI 5-15R) | |
Contextual Info: NCS37010 Product Preview Self Test With Lockout Ground Fault Circuit Interrupter GFCI http://onsemi.com The NCS37010 is a fully UL943 compliant signal processor for GFCI applications with self test and lockout. The device integrates a flexible power supply (including both shunt and LDO regulators), |
Original |
NCS37010 NCS37010 UL943 NCS37010/D | |
Contextual Info: Power It! Safety Power Strip with 8 Outlets and 12-ft. Cord with GFCI Plug MODEL NUMBER: TLM812GF Highlights 8 outlets including transformer outlets and 4 safety covers 12 ft. cord with GFCI plug Cord wrap with hang holes Rugged metal case Applications Industrial |
Original |
12-ft. TLM812GF TLM812GF 145mm | |
Contextual Info: FAN41501 Ground Fault Interrupter Self-Test Digital Controller Features Description • • Meets 2015 UL943 Self-Test GFCI Requirement Periodic EOL Testing without Compromising Normal GFCI Protection Built-in Noise Filters Reduce False EOL Signals |
Original |
FAN41501 UL943 90-Minute com/dwg/MA/MA06A dwg/PKG-MA06A | |
Contextual Info: FAN41501 Ground Fault Interrupter Self-Test Digital Controller Features Description • • Meets 2015 UL943 Self-Test GFCI Requirement Periodic EOL Testing without Compromising Normal GFCI Protection Built-in Noise Filters Reduce False EOL Signals |
Original |
FAN41501 UL943 90-Minute com/dwg/MA/MA06A dwg/PKG-MA06A | |
|
|||
Contextual Info: Power It! Safety Power Strip with 8 Outlets and 25-ft. Cord with GFCI Plug MODEL NUMBER: TLM825GF Highlights 8 outlets including transformer outlets and 4 safety covers 25 ft. extra-long cord with GFCI plug Cord wrap with hang holes Rugged metal case Applications |
Original |
25-ft. TLM825GF TLM825GF 145mm | |
Contextual Info: Power It! Safety Power Strip with 6 Outlets and 9-ft. Cord with GFCI Plug Highlights 6 outlets including transformer outlets and 4 safety covers MODEL NUMBER: TLM609GF 9 ft. cord with GFCI plug Cord wrap with hang holes Rugged metal case Applications Industrial |
Original |
TLM609GF TLM609GF | |
GFCIContextual Info: Ground Fault Circuit Interruptors LineGard 30 Amp Permanent Series Splice-in GFCI • Power and fault status indicators • Industrial design for rough service • Chemical and UV resistant enclosure • cULus Listed as a Class A GFCI per UL 943 and CSA 22.2 No. 144 |
Original |
||
Airpax
Abstract: UL 943 GFCI Airpax ground fault circuit interrupter
|
Original |
||
pfgs
Abstract: Airpax
|
Original |
||
Contextual Info: PGFS Series 30 Amp Permanent Series Splice-In GFCI/ELCI INTRODUCTION The LineGard 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. The unique design offers the flexibility of splicing in protection of a GFCI |
Original |
120/24ays | |
GFCI BREAKER
Abstract: klixon
|
Original |
||
Contextual Info: 8 | PC-Series - Introduction PC-Series Ground Fault Circuit Protection The PC-Series, AC Residual Current Circuit Breaker with Overcurrent Protection RCBO , combines the ground fault protection of a GFCI with the familiar overcurrent tripping characteristics of a normal circuit breaker. |
Original |
||
Contextual Info: Protection Relays & Controls Ground-Fault Ground-Continuity Detection SE-502 SERIES Ground-Fault Ground-Continuity Detector Description The SE-502 Ground-Fault Ground-Continuity Detector provides Class-A GFCI trip level and trip times for personnel protection. |
Original |
SE-502 | |
Contextual Info: PowerVerter 1250W Utility/Work Truck Inverter/Charger with 2 Outlets MODEL NUMBER: UT1250UL Highlights 12V DC or 120VAC input; 120VAC output; 2 GFCI protected outlets 1250 watts continuous, 1875 watts OverPower and 2500 watts DoubleBoost inverter output |
Original |
UT1250UL 120VAC UT1250UL BP-260 com/sku/UT1250UL. |