HEAT EXCHANGER AIR TO AIR Search Results
HEAT EXCHANGER AIR TO AIR Result Highlights (1)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
D1U54T-M-2500-12-HB4C | Murata Manufacturing Co Ltd | 2.5KW 54MM AC/DC 12V WITH 12VDC STBY BACK TO FRONT AIR |
![]() |
HEAT EXCHANGER AIR TO AIR Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
fan heater
Abstract: R2510k heat exchanger water heater AC1500V R250 Air Conditioner water level sensor 3485K AC1800V
|
Original |
B0/100 3450K DC500V, 40sec AC750V B25/50 4100K AC1800V fan heater R2510k heat exchanger water heater AC1500V R250 Air Conditioner water level sensor 3485K | |
Contextual Info: WL 1500 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL1500 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of heat from a liquid circuit. The coolant is |
Original |
WL1500 | |
Contextual Info: WL 500 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL500 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of heat from a liquid circuit. The coolant is |
Original |
WL500 | |
Contextual Info: WL 5000 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL 5000 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of heat from a liquid circuit. The coolant is recirculated using a high pressure pump to assure maximum flow rate. Heat from coolant is |
Original |
||
Contextual Info: WL 2000 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL2000 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of heat from a liquid circuit. The coolant is recirculated using a high pressure pump to assure maximum flow rate. Heat from coolant is |
Original |
WL2000 | |
Contextual Info: WL 3000 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL3000 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of heat from a liquid circuit. The coolant is recirculated using a high pressure pump to assure maximum flow rate. Heat from coolant is |
Original |
WL3000 | |
Contextual Info: WL 1000 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL1000 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of heat from a liquid circuit. The coolant is recirculated using a high pressure pump to assure maximum flow rate. Heat from coolant is |
Original |
WL1000 | |
Contextual Info: Quality Products. Service Excellence. Air/Water Heat Exchanger PWS Series Type 3R, 4, 4X Description Designed to use various water sources to cool enclosures where ambient conditions involve high temperatures, harsh conditions or are subject to frequent wash-down. |
Original |
gal7332A 115N4LG PWS7332A 230N4LG PWS7502A PWS7702A | |
Contextual Info: Quality Products. Service Excellence. Air/Water Heat Exchanger PWS Series Type 3R, 4, 4X Description Designed to use various water sources to cool enclosures where ambient conditions involve high temperatures, harsh conditions or are subject to frequent wash-down. |
Original |
50/60Hz PWS7502A115N4LG PWS7502A230N4LG PWS7702A230N4LG PWS71002A23N4LG | |
THERMO ELECTRIC
Abstract: THP51B THP51 GL56
|
Original |
THP51B THP51B THERMO ELECTRIC THP51 GL56 | |
Contextual Info: FlowGrid for axial and centrifugal fans. Less noise – more quality of life. Innovating for people. FlowGrid stands for … efficient noise protection features in cooling, ventilation and air-conditioning technology. ebm-papst offers a future-oriented solution for the problem of high-performance technology |
Original |
||
Contextual Info: FlowGrid for axial and centrifugal fans. Less noise – more quality of life. Innovating for people. FlowGrid stands for … efficient noise protection features in cooling, ventilation and air-conditioning technology. ebm-papst offers a future-oriented solution for the problem of high-performance technology |
Original |
||
Contextual Info: Calculating Maximum Air Temperature for ThunderSWITCH¥ Devices APPLICATION BRIEF: SPWA017 June 1997 Networking Business Unit IMPORTANT NOTICE Texas Instruments TI reserves the right to make changes to its products or to discontinue any semiconductor product or service without notice, and advises its customers to obtain the latest version of |
Original |
SPWA017 | |
arstechContextual Info: Proceedings of IPACK2007 ASME InterPACK '07 July 8-12, 2007, Vancouver, British Columbia, CANADA IPACK2007-33870 CLOSED LOOP LIQUID COOLING FOR HIGH PERFORMANCE COMPUTER SYSTEMS Sukhvinder Kang kang@aavid.com David Miller John Cennamo Aavid Thermalloy LLC, |
Original |
IPACK2007 IPACK2007-33870 D2570-96 arstech | |
|
|||
Contextual Info: Budapest, Hungary, 17-19 September 2007 Evaluation of Cooling Solutions for Outdoor Electronics Mahendra Wankhede, Vivek Khaire, Dr. Avijit Goswami Applied Thermal Technologies India 3PrdP Floor, C-Wing, Kapil Towers, Dr. Ambedkar Road, Pune – 411001 Maharashtra, India |
Original |
Ph-91-20-66030625 Fax-91-20-66030626 Pune-411005, | |
Contextual Info: Cooling to keep your Key Chips Alive Guy Diemunsch Aavid Thermalloy 70 Commercial Street, Suite 200 Concord, NH 03301 USA Abstract: plenty of cooling technologies are available, they can be used to spread the heat, conduct it to or exchange it with the cold source. We |
Original |
||
Peltier ThermoContextual Info: Power Thermal Solution Solutions Division Cooling to keep your Key Chips Alive Guy Diemunsch Aavid Thermalloy diemunsch.g@aavid.com Agenda Power Thermal Solution Solutions Division From the Chip to the Fluid The story of conductivity and heat density Technologies and Heat Transfer coefficients |
Original |
||
PT100 temperature sensor ABB motor
Abstract: 230v transformer sccf PT 2258 circuit diagram he250 block diagram of suction pump thread gl18 condensate pump unit motor operated valve for gas SR25
|
Original |
||
hydrosinkContextual Info: Bologna Design Center EUDC@aavid.com : a smart and more efficient way to cool power electronics Authors Andrea Meo, AAVID THERMALLOY, Via del Fonditore 4 – 40138 Bologna, ITALY, meo.a@aavid.com Andrea Sce, AAVID THERMALLOY, Via del Fonditore 4 – 40138 Bologna, ITALY, sce.a@aavid.com |
Original |
97/23/EC hydrosink | |
three phase bridge inverter in 180 degree and 120
Abstract: single phase half controlled full wave bridge rec transformer calculation formula AN-305 three phase bridge inverter 120 degree ac to dc inverter by thyristor power semiconductor 1973 thyristor st 103
|
OCR Scan |
AN-305 three phase bridge inverter in 180 degree and 120 single phase half controlled full wave bridge rec transformer calculation formula AN-305 three phase bridge inverter 120 degree ac to dc inverter by thyristor power semiconductor 1973 thyristor st 103 | |
APPLICATIONS OF dc chopper circuit
Abstract: ac to dc chopper transformer ANSI 45 rectifier 1/Varo integrated rectifiers chopper transformer
|
Original |
||
Contextual Info: AA-250-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER MANUAL 1 www.lairdtech.com Laird Technologies Contents Introduction . 3 Incoming Inspection . 3 |
Original |
AA-250-XX | |
ss101
Abstract: PVC Pipe microwave sensor AWG28 Still heat exchanger Response SS113 refrigerator temperature SENSOR surface temperature sensor
|
Original |
200KW SS113 AWG28-24 AWG26-24 AWG28 SS123 AWG28-26 C6A05 ss101 PVC Pipe microwave sensor AWG28 Still heat exchanger Response SS113 refrigerator temperature SENSOR surface temperature sensor | |
1414-CTZ03PBRAA
Abstract: 1414-ITZ02GBRAA 1414-CTX03PDDAA pcb split hvac 1414-CHZ30PKRAA 1414-CHD30PKRAA rtd sensor Allen-Bradley 1414-ITZ02FAOAA in007
|
Original |
1414-SG001A-EN-P 1414-CTZ03PBRAA 1414-ITZ02GBRAA 1414-CTX03PDDAA pcb split hvac 1414-CHZ30PKRAA 1414-CHD30PKRAA rtd sensor Allen-Bradley 1414-ITZ02FAOAA in007 |