TGS 821
Abstract: Carbon Monoxide SENSOR CIRCUIT DIAGRAM figaro TGS 821 sensor figaro 6 pin gas sensor figaro TGS gas sensor figaro TGS methane gas sensor figaro gas sensor hydrogen gas sensor Structure
Text: FIGARO PRODUCT INFORMATION TGS 821 - Special Sensor for Hydrogen Gas Features: Applications: * High sensitivity and selectivity to hydrogen gas * Good repeatability in measurement and excellent stability * Uses simple electrical circuit * Ceramic base resistant to severe
|
Original
|
PDF
|
|
figaro TGS 821 sensor
Abstract: 6 pin gas sensor hydrogen gas sensor figaro TGS gas sensor figaro TGS methane gas sensor ethanol gas sensor figaro gas sensor GAS SENSOR CIRCUIT DIAGRAM Carbon Monoxide SENSOR CIRCUIT DIAGRAM figaro
Text: FIGARO PRODUCT INFORMATION TGS 821 - Special Sensor for Hydrogen Gas Features: Applications: * High sensitivity and selectivity to hydrogen gas * Good repeatability in measurement and excellent stability * Uses simple electrical circuit * Ceramic base resistant to severe
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: E3Point specifications Toxic and Combustible Gas Detector Standalone Platform Single or Dual-Gas Monitoring General Specifications Uses Wall or duct-mounted gas detector for monitoring carbon monoxide (CO), nitrogen dioxide (NO2), oxygen (O2), methane (CH4), hydrogen (H2), hydrogen sulphide (H2S), and propane (C3H8), installed as a standalone device with
|
Original
|
PDF
|
VA201T,
VA201M
VA301M)
17-27Vac)
24Vdc
20-38Vdc)
120Vac,
|
Untitled
Abstract: No abstract text available
Text: ENGAGE. ENABLE. EXCEL. www.excelitas.com HY-11 Hydrogen Filled Triode Thyratron Description The HY-11 is a hydrogen-illed, triode thyratron. The hydrogen gas ill facilitates reliable operation at a lower to moderate voltage and very high pulse repetition rates when compared
|
Original
|
PDF
|
HY-11
HY-11
|
Untitled
Abstract: No abstract text available
Text: E3Point specifications Toxic and Combustible Gas Detector Network Platform BACnet MS-TP, Modbus General Specifications Uses Wall or duct-mounted, BAS or controller networkable gas detector for monitoring carbon monoxide (CO), nitrogen dioxide (NO2), hydrogen sulfide (H2S), oxygen (O2), methane (CH4), hydrogen (H2) and propane (C3H8).
|
Original
|
PDF
|
VA201T)
17-27Vac)
20-38Vdc)
250Vac;
30Vdc
RS485
Tempera122Â
|
Untitled
Abstract: No abstract text available
Text: HY-3002/5948A-Replacement Hydrogen Filled Triode Thyratron NOTE The HY3002/5948A-REPLACEMENT The HY-3002 is a hydrogen-illed, triode thyratron. The hydrogen gas ill facilitates reliable operation is a HY3002 that incorporates a base at a moderately-high voltage and very high pulse repetition rates when compared to similar
|
Original
|
PDF
|
HY-3002/5948A-Replacement
HY3002/5948A-REPLACEMENT
HY-3002
HY3002
HY3002/5948AREPLACEMENT
HY-3002/5984A-Replacement
|
c2h4 sensor
Abstract: No abstract text available
Text: HYDROCAL 1008 Multi-Gas-in-Oil Analysis System with Transformer Monitoring Functions The HYDROCAL 1008 is a permanently installed multi-gas-in-oil analysis system with transformer monitoring functions. It individually measures, Moisture in Oil H2O and the key gases Hydrogen
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: HYDROCAL 1005 Multi-Gas-in-Oil Analysis System with Transformer Monitoring Functions The HYDROCAL 1005 is a permanently installed multi-gas-in-oil analysis system with transformer monitoring functions. It individually measures, Moisture in Oil H2O and the key gases Hydrogen
|
Original
|
PDF
|
|
pellistor
Abstract: pellistor circuit VQ101HT H2S gas detector flammable gas sensor air flow detector sensor VH101HT
Text: VQ101HT Solid-State Gas Sensor Elements for Hydrogen Sulfide monitoring FEATURES • 0 - 50 ppm range H2S • 0.2 ppm resolution • High temperature +90 °C operation • Fast response time t90 • Solid state technology • Designed for continuous operation
|
Original
|
PDF
|
VQ101HT
VH101HT
A1A-767115
pellistor
pellistor circuit
H2S gas detector
flammable gas sensor
air flow detector sensor
|
b.ed
Abstract: gas sensor CO2 gas cartridge HCPS-60
Text: SOF Optoelectronics GmbH Gartenstraße 38 • 52249 Eschweiler HCPS – HYDROGEN CONTINUOUS PURIFICATION SYSTEM Germany Tel. +49 0 24 03 · 51 93 33 Fax +49 (0) 24 03 · 50 89 68 The SOF Optoelectronics HCPS is an integration of two H2-Gas purifier-units and
|
Original
|
PDF
|
HCPS-60
HCPS-300
b.ed
gas sensor CO2
gas cartridge
HCPS-60
|
Untitled
Abstract: No abstract text available
Text: Hydrogen Gas Detectors Forklifts • Backup Power Supplies • Golfcarts • Battery Charging Stations HD-12 HD-21-1-BR System Detectors Low Voltage 120 Volt Unit HD-11 12-24VAC or VDC input, alarm relay. HD-21-1-BR buzzer and relay, mounts in 4 x 4 electrical box.
|
Original
|
PDF
|
HD-12
HD-21-1-BR
HD-11
12-24VAC
HD-21-1-BR
HD-12
HD-12)
HD-11
|
hydrogen gas sensor
Abstract: nitric oxide gas sensor GAS SENSOR for oxygen AWM1000 helium sensor AWM40000 AWM42150VH AWM5000 AWM2100VH oxygen gas sensor
Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Media Compatibility – Note #4 The microbridge mass airflow sensor incorporates a limited number of wetted materials in the construction of the device. The wetted materials in the sensor are fairly non-reactive and are compatible
|
Original
|
PDF
|
AWM2100VH,
AWM2300VH,
AWM42150VH.
hydrogen gas sensor
nitric oxide gas sensor
GAS SENSOR for oxygen
AWM1000
helium sensor
AWM40000
AWM42150VH
AWM5000
AWM2100VH
oxygen gas sensor
|
gas sensor TGS 825
Abstract: hydrogen sulfide gas sensor hydrogen sensor TGS 825 TGS 825 data pin figaro gas sensor Figaro application note figaro sensor figaro figaro TGS 825 gas sensor
Text: FIGARO PRODUCT INFORMATION TGS 825 - Special Sensor for Hydrogen Sulfide Features: Applications: * Hydrogen sulfide detectors/ alarms * High sensitivity to low concentration of hydrogen sulfide * Good repeatability in measurement * Uses simple electrical circuit
|
Original
|
PDF
|
|
helium sensor
Abstract: AWM42150VH nitrogen gas sensor hydrogen and carbon monoxide gas sensor nitric oxide gas sensor gas sensor helium types methane gas sensor gas sensor no2 Transistor A131 helium gas sensor
Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Correction Factors – Note #3 Microbridge mass airflow sensors operate by measuring the rate of relative heat transfer from a heater resistor to a temperature sensing resistor located on either side of the heater. The
|
Original
|
PDF
|
|
|
AWM43000
Abstract: hydrogen gas sensor AWM43300V "Flow Sensor" hydrogen sensor helium sensor AWM43600V ch4 sensor methane carbon dioxide sensor nitrogen dioxide sensor
Text: AWM43000 Series Mass flow sensor for gases FEATURES • Ranges 0.1000 sccm1 and 0.6 slpm2 · Actual mass flow sensing · 1.5 V output · Manifold mount/o-ring sealed SERVICE To be used with dry gases only The AWM series is NOT designed for liquid flow and will be damaged by liquid flow through
|
Original
|
PDF
|
AWM43000
AWM43300V
AWM43600V
AWM43300VH
hydrogen gas sensor
AWM43300V
"Flow Sensor"
hydrogen sensor
helium sensor
AWM43600V
ch4 sensor
methane carbon dioxide sensor
nitrogen dioxide sensor
|
TGS2600
Abstract: Figaro TGS2600 sensors TGS 2600 SENSOR TGS 2600 GAS SENSOR TGS 2600 FIGARO cigarette Smoke Sensor circuit figaro TGS methane gas sensor isobutane gas sensor Smoke Sensor circuit
Text: an ISO9001 company TECHNICAL INFORMATION FOR TGS2600 Technical Information for Air Quality Control Sensors The Figaro 2600 series is a new type thick film metal oxide semiconductor, screen printed gas sensor which offers miniaturization and lower power consumption. The TGS2600
|
Original
|
PDF
|
ISO9001
TGS2600
10ppm
50ppm
TGS2600
Figaro TGS2600 sensors
TGS 2600
SENSOR TGS 2600
GAS SENSOR TGS 2600
FIGARO
cigarette Smoke Sensor circuit
figaro TGS methane gas sensor
isobutane gas sensor
Smoke Sensor circuit
|
helium sensor
Abstract: "Flow Sensor" AWM42000 hydrogen gas sensor AWM42150VH nh3 sensor gas sensor helium gas sensor no2 AWM42150VH application nitric oxide sensor
Text: AWM42000 Series Mass flow sensor for gases FEATURES • Ranges 0.±25 and 0.±1000 sccm1 · Bidirectional sensing · Actual mass flow sensing · Ceramic flow tube · Manifold mount/o-ring sealed SERVICE To be used with dry gases only. The AWM42150VH is a special sensor for
|
Original
|
PDF
|
AWM42000
AWM42150VH
AWM42150VH
AWM42300V
helium sensor
"Flow Sensor"
hydrogen gas sensor
nh3 sensor
gas sensor helium
gas sensor no2
AWM42150VH application
nitric oxide sensor
|
"Flow Sensor"
Abstract: helium sensor AWM2100V AWM2200V AWM2000 6 pin gas sensor AWM2150V AWM2300V AWM2300VH AWM2100VH
Text: AWM2000 Series Mass flow sensor for gases FEATURES • Ranges 0.±30 to 0.±1000 sccm1 or 0.±4 "H2O 0.±10 mbar · Bidirectional sensing · Actual mass flow sensing · Low differential pressure sensing SERVICE To be used with dry gases only The AWM series is NOT designed for liquid
|
Original
|
PDF
|
AWM2000
gas11
AWM2150V
AWM2100V
AWM2100VH
AWM2300V
AWM2300VH
AWM2200V
"Flow Sensor"
helium sensor
AWM2100V
AWM2200V
6 pin gas sensor
AWM2150V
AWM2300V
AWM2300VH
AWM2100VH
|
"Flow Sensor"
Abstract: Flow Sensors FMOM025HB NO2 sensor SensorTechnics mass flow
Text: FMO Series Mass flow sensors for gases FEATURES • Ranges 0.±25 and 0.±1000 sccm1 · Bidirectional sensing · Actual mass flow sensing · Ceramic flow tube · Manifold mount/O-ring sealed · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only.
|
Original
|
PDF
|
FMOM025HB
"Flow Sensor"
Flow Sensors
NO2 sensor
SensorTechnics mass flow
|
Capteur Sensors
Abstract: electrochemical gas sensors datasheet GS05 hydrogen gas sensor CO Gas sensor data sheet hydrogen sensor carbon monoxide sensor electrochemical thick film co gas sensor propane gas methane sensor
Text: GS05 Hydrogen Sulphide Sensor SPECIFICATION 3x3 mm Standard Power GS05 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 475 ± 30°C Typical Value 14 ± 3Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH
|
Original
|
PDF
|
25ppm
50ppm
100ppm
Capteur Sensors
electrochemical gas sensors datasheet
GS05
hydrogen gas sensor
CO Gas sensor
data sheet hydrogen sensor
carbon monoxide sensor electrochemical
thick film co gas sensor
propane gas
methane sensor
|
"Flow Sensor"
Abstract: helium sensor hydrogen gas sensor AWM90000 AWM92100V AWM92200V CO2 SENSOR liquid density sensor nitrous oxide sensor gas sensor CO
Text: AWM90000 Series Mass flow sensor for gases FEATURES • Ranges 0.±200 sccm1 or 0.±2 "H2O 0.±5 mbar · Bidirectional sensing · Actual mass flow sensing · Low differential pressure sensing SERVICE To be used with dry gases only The AWM series is NOT designed for liquid
|
Original
|
PDF
|
AWM90000
AWM92100V
AWM92200V
"Flow Sensor"
helium sensor
hydrogen gas sensor
AWM92100V
AWM92200V
CO2 SENSOR
liquid density sensor
nitrous oxide sensor
gas sensor CO
|
Untitled
Abstract: No abstract text available
Text: GAS CONVERSION FACTORS For FMA-5600, FMA-5700 and FMA-8500 Flow Sensors The FMA-5600, FMA-700/800 , and FMA-8500 Electronic Mass Flowmeters and Controllers are factory calibrated for nitrogen, N2 . However, these units can be used for many gases, with the
|
Original
|
PDF
|
FMA-5600,
FMA-5700
FMA-8500
FMA-700/800
FMA-5600
FMA-8500
C4H10)
FMA-8506
|
Untitled
Abstract: No abstract text available
Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Media Compatibility - Note # 4 The microbridge mass airflow sensor in corporates a limited number of wetted materials in the construction of the de vice. The wetted materials in the sensor
|
OCR Scan
|
PDF
|
AWM21OOVH,
AWM2300VH,
AWM42150VH.
1-800-737-3360Canada
|
Untitled
Abstract: No abstract text available
Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Correction Factors - Note # 3 Microbridge mass airflow sensors operate by measuring the rate of relative heat transfer from a heater resistor to a temper ature sensing resistor located on either side of the heater. The
|
OCR Scan
|
PDF
|
|