440R-D23171
Abstract: guardmaster IEC 60947-5-1 440R-D23166 Allen-Bradley MSR125H MSR125H GuardMaster 440r MSR125HP allen bradley IEC 60947-5-1 440R-D23163 MSR125HP A
Text: Safety Relays Two Hand Relays Minotaur MSR125H/HP Specifications Standards EN 574, EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 4 per EN 954-1 ISO 13849-1 Cat. IIIC per EN 574 Approvals C-Tick, CE marked for all
|
Original
|
PDF
|
MSR125H/HP
AS4024
MSR125H/HP
MSR125H/440R-D23163
440R-D23171
guardmaster IEC 60947-5-1
440R-D23166
Allen-Bradley MSR125H
MSR125H
GuardMaster 440r
MSR125HP
allen bradley IEC 60947-5-1
440R-D23163
MSR125HP A
|
varistor CD 222 M
Abstract: LC1 Schneider lc1sk IEC 60947-4-1 schneider lc1sk0600 IEC 60947-4-1 50/60HZ IEC 60947-4-1 LC1-SK06 IEC/EN 60947-4-1 IEC/EN 60947-5-1
Text: 22100_Ver2.00-EN.backup.fm Page 2 Thursday, October 25, 2001 4:40 PM Characteristics Contactors Mini-contactors types LC1-SK and LP1-SK Environment Rated insulation voltage Ui 2 2.1 Conforming to IEC/EN 60947-1, IEC/EN 60947-4-1, VDE 0110 gr C, CSA 22-2 n˚ 14, UL 508
|
Original
|
PDF
|
00-EN
21/NC
LA1-SK01
13/NO
LA1-SK10
LP1-SK06
33/NO
41/NC
varistor CD 222 M
LC1 Schneider
lc1sk
IEC 60947-4-1 schneider
lc1sk0600
IEC 60947-4-1 50/60HZ
IEC 60947-4-1
LC1-SK06
IEC/EN 60947-4-1
IEC/EN 60947-5-1
|
A5268
Abstract: lc1skgc310 IEC 60947-4-1 schneider LC1 Schneider EN 60947-4-1 LC1-SKGC310 LC1-SKGC200 contactor schneider IEC/EN 60947-5-1 LC1SKGC200
Text: 22103 Page 10 Thursday, October 25, 2001 4:50 PM Characteristics Contactors Mini-contactors type LC1-SKGC for use in modular panels Environment Rated insulation voltage Ui 2 2.1 Conforming to IEC/EN 60947-1, IEC/EN 60947-4-1, VDE 0110 gr C, CSA 22-2 n˚ 14, UL 508
|
Original
|
PDF
|
00-EN
21/NC
13/NO
LC1-SKGC301
LC1-SKGC310
LC1-SKGC400
A5268
lc1skgc310
IEC 60947-4-1 schneider
LC1 Schneider
EN 60947-4-1
LC1-SKGC310
LC1-SKGC200
contactor schneider
IEC/EN 60947-5-1
LC1SKGC200
|
Contactors MC
Abstract: Contactors A MC-12B-AC480V Varistor 240v MC-50A-AC480V GMC-12M-10-AC120V
Text: Contactors MC-Series Contactor 3 Pole UL508 E108780 Standards and Certifications • UL508 • IEC 60947-2 & IEC 60947-4-2 • CSA C22.2 No.14 Features • • • • • 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals Lug Terminals Available
|
Original
|
PDF
|
UL508
E108780
600HP
5-300Hz)
50/60Hz
GMC-6M-12M
AS-12M/4
Contactors MC
Contactors A
MC-12B-AC480V
Varistor 240v
MC-50A-AC480V
GMC-12M-10-AC120V
|
VDE 0660 iec 158-1
Abstract: NFC-63110 IEC 158-1 VDE 0660 NFC63-110 32A 4 pole relay 230v ac JEM1038 iec 947-4 BS5424 IEC 158-1 VDE 0660 DC contactor 220V VDE0660
Text: 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ 40A Rated insulation voltage Ui (Conforming to IEC 158-1) V IEC 60947-4 V Conforming to standards 750 1000 NFC63-110, VDE0660, BS5424, JEM1038 & IEC60947-4
|
Original
|
PDF
|
NFC63-110,
VDE0660,
BS5424,
JEM1038
IEC60947-4
VDE 0660 iec 158-1
NFC-63110
IEC 158-1 VDE 0660
NFC63-110
32A 4 pole relay 230v ac
JEM1038
iec 947-4
BS5424 IEC 158-1 VDE 0660
DC contactor 220V
VDE0660
|
440R-ZBE820AZ1
Abstract: MSR19E 440r minotaur MSR18T relay B1- 5.5 24v 24v 8 channel Relay IEC 60947-5-1 24V 5A VDE RELAY MSR18T relay 220V
Text: Safety Relays Expansion Units Minotaur MSR19E Specifications Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 4 per EN 954-1 ISO 13849-1 Approvals CE marked for all applicable directives and cULus Power Supply AZ1 and AZ2
|
Original
|
PDF
|
MSR19E
AS4024
MSR19E
relay14
MSR18T
440R-ZBE820AZ1
440r
minotaur MSR18T
relay B1- 5.5 24v
24v 8 channel Relay
IEC 60947-5-1
24V 5A VDE RELAY
MSR18T
relay 220V
|
D-53115
Abstract: No abstract text available
Text: Page 1 of 4 Type: LS-02 Article No.: 266107 Basic unit Ordering information Auxiliary contacts: = safety function, by positive opening to IEC/EN 60947-5-1 N/C = Normally closed 2 N/C Housing Plastic version Contact sequence Contact diagram Page 2 of 4 Colour of enclosure cover
|
Original
|
PDF
|
LS-02
1\e0318543\LOCALS
D-53115
HPL-C2006GB-INT
|
Untitled
Abstract: No abstract text available
Text: Signals & data 5.00 / 5.08 mm pitch Socket connectors with leaf spring connection BL 5.08 BL 5.00 Derating curve BL 5.08 BL 5.00 • 0.2 - 1.5 mm2 IEC / 26 - 14 AWG (UL) • 400 V (IEC) / 300 V (UL) • 14 A (IEC) / 10 A (UL) 18 16 14 12 10 8 6 4 2 Conductor current to EN 60947-7-1
|
Original
|
PDF
|
H07V-K1
16-pole)
H05V-K0
|
connector SL5.08
Abstract: 1716380000 1716320000 1723110000 SL5.08
Text: Signals & data 5.00 / 5.08 mm pitch Socket connectors with leaf spring connection BL 5.08 BL 5.00 Derating curve BL 5.08 BL 5.00 • 0.2 - 1.5 mm2 IEC / 26 - 14 AWG (UL) • 400 V (IEC) / 300 V (UL) • 14 A (IEC) / 10 A (UL) 18 16 14 12 10 8 6 4 2 Conductor current to EN 60947-7-1
|
Original
|
PDF
|
H07V-K1
16-pole)
H05V-K0
connector SL5.08
1716380000
1716320000
1723110000
SL5.08
|
LR2K
Abstract: k0302 LR2-K0301 k0312 k0308 k0305 LR2-K0310 k0307 k0316 LR2-K0305
Text: 22008_Ver4.00-EN.fm Page 44 Thursday, October 25, 2001 5:24 PM Characteristics Protection relays K thermal overload relays, adjustable from 0.11 to 16 A Environment Conforming to standards 2 IEC/EN 60947-4-1, NF C 63-650, VDE 0660 Approvals Pending UL, CSA
|
Original
|
PDF
|
00-EN
LA7-K0064
AM1-DP200
AM1-DE200)
AM1DP200
DE200
LR2K
k0302
LR2-K0301
k0312
k0308
k0305
LR2-K0310
k0307
k0316
LR2-K0305
|
LC1 D093
Abstract: LC1 D253 LC1 D323 tesys d contactors LC1 D123 LC1DT60A LC1 D32 wiring LC1-D093 LC1-D323 LC1-D123
Text: TeSys contactors Characteristics TeSys D contactors Contactor type LC1 D09…D18 DT20 and DT25 D25…D38 DT32 and DT40 D40A…D65A DT60A and DT80A D80…D95 D115 and D150 Environment Rated insulation voltage Ui Rated impulse withstand voltage (Uimp) Conforming to IEC 60947-4-1,
|
Original
|
PDF
|
DT60A
DT80A
DC-13
24505-EN
LC1 D093
LC1 D253
LC1 D323
tesys d contactors
LC1 D123
LC1DT60A
LC1 D32 wiring
LC1-D093
LC1-D323
LC1-D123
|
EN 60947-5-1
Abstract: D-53115
Text: Page 1 of 4 Type: LS-20 Article No.: 266120 Basic unit Ordering information Auxiliary contacts: = safety function, by positive opening to IEC/EN 60947-5-1 N/O = Normally open 2 N/O Housing Plastic version Contact sequence Contact diagram
|
Original
|
PDF
|
LS-20
1\e0318543\LOCALS
D-53115
HPL-C2006GB-INT
EN 60947-5-1
|
siemens IEC 60947-4-1
Abstract: 3RV13 11 kw SIEMENS motor DMT 98 41-4KC10 41-4LC10 41-4JC10 Siemens IEC MOTOR CONTACTOR 31-4HC10 siemens 3RV13 21
Text: Overload Relays 3RU1 Thermal Overload Relays 3RU11 for standard applications • Technical specifications Type 3RU11 16 3RU11 26 3RU11 36 3RU11 46 Size S00 S0 S2 S3 Width 45mm 45mm 55mm 70mm General data Overload and phase failure Trips in the event of Trip class according to IEC 60947-4-1
|
Original
|
PDF
|
3RU11
3RV13
41-4MC10
siemens IEC 60947-4-1
11 kw SIEMENS motor
DMT 98
41-4KC10
41-4LC10
41-4JC10
Siemens IEC MOTOR CONTACTOR
31-4HC10
siemens 3RV13 21
|
KEMA97ATEX1798U
Abstract: DIN-46228-4 ATEX
Text: Datasheet SAK terminal with screw connection SAK 4/35 BL Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-2083 www.weidmueller.com The Weidmüller SAK feed-through terminals satisfy the requirements of IEC 60947-1 and are available with rated
|
Original
|
PDF
|
D-32758
EC000897
GOSTME25;
KEMA97ATEX1798U
DIN-46228-4
ATEX
|
|
KEMA97ATEX1798U
Abstract: No abstract text available
Text: Datasheet SAK terminal with screw connection SAK 4/35 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-2083 www.weidmueller.com The Weidmüller SAK feed-through terminals satisfy the requirements of IEC 60947-1 and are available with rated
|
Original
|
PDF
|
D-32758
EC000897
GOSTME25;
KEMA97ATEX1798U
|
wiring diagram contactor 220v.ac
Abstract: No abstract text available
Text: Contactors Ex9C • Contactors according to IEC / EN 60947-4-1 • Four frame sizes with rated current up to 100 A at 400 V AC-3 • 3-pole versions • Coil control voltage 24 — 415 V AC • Rated conditional short circuit current Iq 50 kA • Suitable mainly for industrial applications,
|
Original
|
PDF
|
AX43x2)
wiring diagram contactor 220v.ac
|
UR E60693
Abstract: No abstract text available
Text: Data sheet. SAK Series AKZ 4 WEMID BL Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com The Weidmüller SAK feed-through terminals satisfy the requirements of IEC 60947-1 and are available with rated
|
Original
|
PDF
|
D-32758
EC001283
UR E60693
|
Untitled
Abstract: No abstract text available
Text: Data sheet SAK Series SAK 4/35 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com The Weidmüller SAK feed-through terminals satisfy the requirements of IEC 60947-1 and are available with rated
|
Original
|
PDF
|
D-32758
|
Untitled
Abstract: No abstract text available
Text: Data sheet. SAK Series DK 4 QV/EN Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com The Weidmüller SAK feed-through terminals satisfy the requirements of IEC 60947-1 and are available with rated
|
Original
|
PDF
|
D-32758
EC000897
|
Untitled
Abstract: No abstract text available
Text: Data sheet. SAK Series AKZ 4 WEMID Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com The Weidmüller SAK feed-through terminals satisfy the requirements of IEC 60947-1 and are available with rated
|
Original
|
PDF
|
D-32758
EC001283
|
EPBCD45
Abstract: "Power Distribution block"
Text: Product Data Sheet EPBCD45 Listed Power Distribution Block 200 Amps, 600 Volts AC/DC 1,000V AC/DC CE (IEC 60947-7-1) Wire Range: Line side: (1) 3/0 - #14 AWG (70 mm² - 2.5 mm²) Load Side: (4) #2 - #14 AWG (25 mm² - 2.5 mm²) Shown here on Din Rail See tables below for SCCR wire ranges, flexible stranded and multiple wire
|
Original
|
PDF
|
EPBCD45
IP-20
MN35-2
MSK35
8367A23
8367A24
EPBCD45
"Power Distribution block"
|
EPBAD45
Abstract: E112158 I342
Text: Product Data Sheet EPBAD45 Listed Power Distribution Block 200 Amps, 600 Volts AC/DC 1,000V AC/DC CE (IEC 60947-7-1) Wire Range: Line side: (1) 3/0 - #14 AWG (70 mm² - 2.5 mm²) Load Side: (4) #2 - #14 AWG (25 mm² - 2.5 mm²) Shown here on Din Rail See tables below for SCCR wire ranges, flexible stranded and multiple wire approvals, and wire
|
Original
|
PDF
|
EPBAD45
IP-20
MN35-2
MSK35
8367A23
8367A24
EPBAD45
E112158
I342
|
Untitled
Abstract: No abstract text available
Text: Panel feed-through terminals Panel feed-through terminals Overview F.2 Panel feed-through terminals WGK F.3 Panel feed-through terminals Contents F F.1 Panel feed-through terminals Overview Panel feed-through terminals With the new WGK series of panel feedthrough terminals,
|
Original
|
PDF
|
94-V0,
5x100
0x100
|
M625
Abstract: IEC 60947-7-1 IEC 60947 iec+60947-7-1+phoenix+contact
Text: D a t a s h e e t • M o d u l a r Te r m i n a l B l o c k s Panel feed-through terminals WGK NEW W ith the new WGK series of panel feedthrough terminals, Weidmüller offers a universal solution for feeding currents of different magnitudes through enclosure
|
Original
|
PDF
|
94-V0,
M625
IEC 60947-7-1
IEC 60947
iec+60947-7-1+phoenix+contact
|