Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ISOLATOR ROTARY SWITCH Search Results

    ISOLATOR ROTARY SWITCH Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DCL541A01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Input disable Visit Toshiba Electronic Devices & Storage Corporation
    DCL542H01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=2:2) / Default Output Logic: High / Output enable Visit Toshiba Electronic Devices & Storage Corporation
    DCL541B01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: High / Input disable Visit Toshiba Electronic Devices & Storage Corporation
    DCL542L01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=2:2) / Default Output Logic: Low / Output enable Visit Toshiba Electronic Devices & Storage Corporation
    DCL540H01 Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=4:0) / Default Output Logic: High / Output enable Visit Toshiba Electronic Devices & Storage Corporation

    ISOLATOR ROTARY SWITCH Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    vde 0660-107

    Abstract: 25 AMP ROTARY ISOLATOR SWITCH 4 POLE rotary isolator switch 380-440V AC-21A VDE 0660-107 iec 947-3 2 position rotary switch panel mount AC22 CSA-C22 LB20
    Text: Rotary Isolator Load Break Switch Data Sheet Panel Mount     UL & CSA Approved Degree of protection IP65 Panel Mount RoHS Compliant 2 hole rear mounting or snap on mounting to 35mm DIN Rail. Operable from the front (door) coupled with the door mechanism.


    Original
    PDF 280mm) AC-15 AC-21 AC-22 AC-23 DC-13 vde 0660-107 25 AMP ROTARY ISOLATOR SWITCH 4 POLE rotary isolator switch 380-440V AC-21A VDE 0660-107 iec 947-3 2 position rotary switch panel mount AC22 CSA-C22 LB20

    rotary isolator switch

    Abstract: 2 position rotary switch panel mount din mount 35mm isolator rotary switch
    Text: RS LBPM & LBDI Data Sheet:Layout 1 7/7/10 11:19 Page 1 Rotary Isolator Load Break Switch Data Sheet Panel Mount RoHS UL & CSA Approved Degree of protection IP65 Panel Mount RoHS Compliant 4 hole front panel mounting. Switch with round padlocking device to prevent the switch from being switched ON by


    Original
    PDF 280mm) rotary isolator switch 2 position rotary switch panel mount din mount 35mm isolator rotary switch

    rotary isolator switch

    Abstract: 25 AMP ROTARY ISOLATOR SWITCH 4 POLE 380-440V vde 0660-107 isolator rotary switch LBDI633P mains isolators LBDI803P 16 position rotary switch panel mount csa-c22 vde 0660-107
    Text: Rotary Isolators 3 Pole LBPM 25 to 63A: LBDI 25 to 63A: LBPM 25 to 63A: Features: LBPM 25 to 63A: • Degree of protection IP65. • Panel mount. • RoHS compliant. • 2 hole rear mounting or snap on mounting to 35mm DIN rail. • Operable from the front door coupled with the door mechanism.


    Original
    PDF 280mm. rotary isolator switch 25 AMP ROTARY ISOLATOR SWITCH 4 POLE 380-440V vde 0660-107 isolator rotary switch LBDI633P mains isolators LBDI803P 16 position rotary switch panel mount csa-c22 vde 0660-107

    ELCB 3 phase CONNECTION DIAGRAM

    Abstract: DZ158-1-125A 3 pole 25KA 100A NB310L ELCB CONNECTION DIAGRAM 400 NDK 23 MRJ4M-LS02 dz158 isolators 415v 4 pole Low Voltage Isolator Switch
    Text: ILLUSTRATED CATALOGUE VALID FROM MARCH 2014 CIRCUIT PROTECTION EQUIPMENT MOTOR CONTROL GEAR COMPONENTS POWER PROTECTION DEVICES Inverter n ACB n Solar Panel n Resin Core Transformer n Oil Filled Transformer For further information on each of these products


    Original
    PDF 26ments PLBR03 ELCB 3 phase CONNECTION DIAGRAM DZ158-1-125A 3 pole 25KA 100A NB310L ELCB CONNECTION DIAGRAM 400 NDK 23 MRJ4M-LS02 dz158 isolators 415v 4 pole Low Voltage Isolator Switch

    gpib

    Abstract: GPIB-120A rotary isolator switch ieee-488 gpib isolator rotary switch
    Text: GPIB Expander/Isolator and Mechanical Switches GPIB Expander/Isolator NI GPIB-120A • Expands the number of GPIB devices to 28 • Bidirectional expansion – Controllers, Talkers, and Listeners can exist on either side of the expansion • 400 Vrms electrical isolation between


    Original
    PDF GPIB-120A GPIB-120A gpib rotary isolator switch ieee-488 gpib isolator rotary switch

    Untitled

    Abstract: No abstract text available
    Text: Edwards Signaling Catalog u Intelligent Input-Output Intelligent Input-Output Modules Models: E-2WIRE, E-IDC1A, E-IDC2B, E-IDCWS, E-ISO, E-NAC, E-RLY, E-IDC1B Overview Standard Features Edwards intelligent modules are engineered to deliver high-perfor­ mance features, superb reliability, and unbeatable quality. From


    Original
    PDF S85001-0611

    rotary isolator switch

    Abstract: atex transformer p1-32 i2 svb moeller AC-23A D-53115 star-delta starting motors moeller fingerprint 132 KW motor
    Text: Important general mounting and application note: • only category 3D suitable cable glands can be used! • only heat-resistant cables can be used >90 °C ! • the surface temperature is a maximum of 90 °C! • only permissible with an ambient temperature from -20 °C to +40 °C!


    Original
    PDF AC23A rotary isolator switch atex transformer p1-32 i2 svb moeller AC-23A D-53115 star-delta starting motors moeller fingerprint 132 KW motor

    Untitled

    Abstract: No abstract text available
    Text: Velociti Series ASD-IL2F Description Analog, Addressable Ionization Smoke Sensor The Gamewell-FCI Velociti® Series, analog addressable plug-in smoke sensors with integral communication provide features that surpass conventional sensors. Sensor sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Velociti Series ATD-L2F, ATD-RL2F Description Addressable Thermal Sensor The Gamewell-FCI Velociti® Series, addressable plug-in thermal sensors with integral communication provide features that surpass conventional sensors. Point ID capability allows each sensor’s address to be set, providing exact


    Original
    PDF

    flammability of magnet wire

    Abstract: No abstract text available
    Text: SS-APT Features • Automatically adjusts sensitivity levels without the need for operator intervention or programming. Sensitivity increases with heat. Acclimate Multi-Sensor Smoke Detector Low-Profile, Intelligent, Addressable • Microprocessor-based, combination


    Original
    PDF 6937pho1 B224BI CS-2462 flammability of magnet wire

    Untitled

    Abstract: No abstract text available
    Text: SS-T Series Features Intelligent Addressable Plug-In Thermal Heat Detectors Description Gamewell’s SmartScanTM intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors. Detector sensi6936pho1.jpg


    Original
    PDF sensi6936pho1 detectio15 CS-2460

    Light Detector laser

    Abstract: No abstract text available
    Text: SS-L Features • Advanced laser light source and patented optical design. Laser Smoke Detector • Sleek low-profile housing 1.66"/ 42.164 mm height . • Sensitivity to 0.03%/foot. Description The Gamewell SmartScanTM SS-L Laser Detector provides a revolutionary advance in early warning


    Original
    PDF 5306d1 CS-2461 Light Detector laser

    h4 bulb wiring diagram

    Abstract: Momentary Push Button Switch 12mm P43T BASE bulb h4 bulb halogen bulb circuit diagram transistor b566 h3 bulb 4 pole Low Voltage Isolator Switch "Rocker Switch" MCC panel design
    Text: Fax 01477 537688 Item Ref. MBS1 MBS1EKEY MBS2 MBS2KEY RES33 MBS3 MMBS4 MMBS4key MBS1 MMBS5 MMBS6 MMBS7 MCOS2 Issue 3A 2006 Tel 01477 533320 Switches Battery Master Switches Description Cut off switch Spare Key for MBS1 FIA Cut off switch with aux NC & NO contacts & resistor


    Original
    PDF RES33 h4 bulb wiring diagram Momentary Push Button Switch 12mm P43T BASE bulb h4 bulb halogen bulb circuit diagram transistor b566 h3 bulb 4 pole Low Voltage Isolator Switch "Rocker Switch" MCC panel design

    Untitled

    Abstract: No abstract text available
    Text: Velociti Series MCS-ACCLIMATE2F Description Multi-Criteria Analog, Addressable Sensor The Gamewell-FCI Velociti® Series, MCS-ACCLIMATE2F sensor is an analog, addressable, multisensing, low-profile sensor designed for use with the Gamewell-FCI analog addressable fire alarm control


    Original
    PDF B224BI B200S B200SR RA-100Z BCK-200

    Moeller p1 - 32

    Abstract: Moeller P1-32 atex transformer star-delta starting motors p1-32 i2 svb moeller rotary isolator switch P1-25/I2/SVB AC-23A D-53115 switch-disconnectors
    Text: Important general mounting and application note: • only category 3D suitable cable glands can be used! • only heat-resistant cables can be used >90 °C ! • the surface temperature is a maximum of 90 °C! • only permissible with an ambient temperature from -20 °C to +40 °C!


    Original
    PDF AC23A Moeller p1 - 32 Moeller P1-32 atex transformer star-delta starting motors p1-32 i2 svb moeller rotary isolator switch P1-25/I2/SVB AC-23A D-53115 switch-disconnectors

    Untitled

    Abstract: No abstract text available
    Text: Velociti Series ASD-PL2F, ASD-PTL2F and ASD-PL2FR Description Analog, Addressable Photoelectronic Smoke Sensor The Gamewell-FCI Velociti® Series, analog addressable plug-in smoke sensors with integral communication provide features that surpass conventional


    Original
    PDF 8649th

    MOELLER Z00 10

    Abstract: DF5-322-1K5 PKZM0-XDM12 DF5-322-2K2 DIL00AM DF5-322-075 DF5-340-7K5 DS4-340-15K-MX dil2m DIL00M
    Text: www.moeller.co.uk Industrial Switchgear Short Form Catalogue 2005/2006 Think future. Switch to green. Moeller – Market leaders in industrial switchgear Moeller has been at the forefront of switching, protecting and controlling motors for over 100 years. Setting standards with DIL contactors and PKZ


    Original
    PDF D-53115 SK0211-1149GB MOELLER Z00 10 DF5-322-1K5 PKZM0-XDM12 DF5-322-2K2 DIL00AM DF5-322-075 DF5-340-7K5 DS4-340-15K-MX dil2m DIL00M

    circuit diagram MPPT CONTROLLER

    Abstract: ADM485 application note AD7280 rogowski coil analog integrator io-homecontrol ADE7763 ADM3072 mppt ic solar inverters circuit diagram Solar Controller mppt GRID ic
    Text: Your Semiconductor Solutions Resource Volume 10, Issue 4 EMERGING ENERGY APPLICATIONS Contents Renewable Energy Generation Renewable Energy Generation Energy Storage System for Solar Photovoltaic and Wind Turbine Generators Safe and Efficient Solutions for


    Original
    PDF

    PT02H

    Abstract: HFTT405S-1 uav design PT02H-8-4P
    Text: Lancaster HFTT405S-1 Telemetry Transmitter 3061 Industry Drive, Lancaster, PA 17603-4025 • Tel 717-397-2777 • Fax 717-397-7079 • www.herley.com FEATURES: The HFTT405S-1 Telemetry Transmitter is an S-band, Continuous Wave CW FM Transmitter used primarily to relay telemetry data or video to a receiving ground station.


    Original
    PDF HFTT405S-1 HFTT405S-1 PT02H-8-4P PT02H uav design PT02H-8-4P

    siemens contactor IEC 60947 VDE 0660

    Abstract: catalog for 3RT series contactor* siemens catalog for 3RT Power contactor* siemens Sirius 3Rv catalog for 3RU overload relays siemens DMT 02 ATEX F 001 dmt 90 atex g 001 siemens magnetic contactor 3VU13 siemens IEC 60947-4-1
    Text: Protection Equipment Circuit Breakers • Molded Case Motor Starter Protectors Reference Manual • April 2009 Low-Voltage Controls and Distribution Protection Equipment 4 7 8 10 10 13 23 24 27 27 28 29 30 32 33 33 34 34 35 42 43 44 45 46 48 49 50 51 51 52


    Original
    PDF

    schematic diagram DC circuit breaker

    Abstract: IEC 947-2 VDE 0660 J7MN-25-1 schematic diagram ac circuit breaker VDE 0660 u MINIATURE CIRCUIT BREAKER Breaking capacity limit switch VDE 0660 IEC 60947-4-1 J7KN-10-10 J7MN
    Text: Motor Protection Circuit Breaker ker MPCB B) ) MPCB system (motor protection CLASS LASS 10) • Rotary and switch types • Rated operational current = 12 A, 25 A and 50 A • Switching capacity up to 12.5 A = 100 kA/400 V • Fixed short-circuit release = 13 x Iu


    Original
    PDF kA/400 J74MN-P12 J74MN-P25 J74MN-PF12 J74MN-DC J74MN-L3- J7MN-12 J7MN-25, J74MN-TC12 J74MN-TC25 schematic diagram DC circuit breaker IEC 947-2 VDE 0660 J7MN-25-1 schematic diagram ac circuit breaker VDE 0660 u MINIATURE CIRCUIT BREAKER Breaking capacity limit switch VDE 0660 IEC 60947-4-1 J7KN-10-10 J7MN

    DMT 02 ATEX F 001

    Abstract: 3RT siemens siemens 3rv1 siemens master trip relay Sirius 3Rv catalog for 3RT series contactor* siemens siemens 3RV10 73 3VU13 3RV13 3RV16
    Text: Protection Equipment Circuit Breakers • Molded-Case Circuit Breakers Reference Manual • March 2010 Industrial Controls Protection Equipment 2 4 5 7 7 10 21 22 25 25 26 27 28 30 31 31 32 32 33 40 41 42 43 44 46 47 48 49 49 50 Introduction 3RV Motor Starter Protectors/Circuit Breakers


    Original
    PDF

    10 kw schematic induction heating

    Abstract: shunt release contact mpcb IEC 947-2 VDE 0660 VDE 0660 iec 947-2 reversible d.c. motors wiring schematic rotary operating mechanism 15 KW induction motor 440v 3phase VDE 0106 1010 shunt release coil function 3-phase induction motors test results
    Text: Motor Protection Circuit Breaker MPCB J7MN ) MPCB system (motor protection CLASS 10) • Rotary and switch types • Rated operational current = 12 A, 25 A and 50 A • Switching capacity up to 12.5 A = 100 kA/400 V • Fixed short-circuit release = 13 x Iu


    Original
    PDF kA/400 10 kw schematic induction heating shunt release contact mpcb IEC 947-2 VDE 0660 VDE 0660 iec 947-2 reversible d.c. motors wiring schematic rotary operating mechanism 15 KW induction motor 440v 3phase VDE 0106 1010 shunt release coil function 3-phase induction motors test results

    P1-25-EA-SVB

    Abstract: Moeller T0-2-8900 Moeller P1-32 P1-32-EA-SVB P3-63-EA-SVB T0-2-1-EA-SVB moeller VDE 0660 iec 947-3 TM-2-8230 T0-2-15679 moeller VDE 0660 typ 156
    Text: 07/000 Rotary Switches Switch-Disconnectors T Rotary Switches, P Switch-Disconnectors Moeller HPL0211-2001/2002 07/001 Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview TM mini rotary switches Overview of functions Page 07/002 Overview of functions


    Original
    PDF HPL0211-2001/2002 P1-25-EA-SVB Moeller T0-2-8900 Moeller P1-32 P1-32-EA-SVB P3-63-EA-SVB T0-2-1-EA-SVB moeller VDE 0660 iec 947-3 TM-2-8230 T0-2-15679 moeller VDE 0660 typ 156