Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MAGNETRON RADAR Search Results

    MAGNETRON RADAR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    AWR6443ABGABLQ1
    Texas Instruments Single-chip 60-GHz to 64-GHz automotive radar sensor integrating MCU and radar accelerator 161-FCCSP -40 to 125 Visit Texas Instruments
    AWR6443ABGABLRQ1
    Texas Instruments Single-chip 60-GHz to 64-GHz automotive radar sensor integrating MCU and radar accelerator 161-FCCSP -40 to 125 Visit Texas Instruments Buy
    IWR1843AQGABL
    Texas Instruments Single-chip 76-GHz to 81-GHz industrial radar sensor integrating DSP, MCU and radar accelerator 161-FC/CSP -40 to 105 Visit Texas Instruments Buy
    AWR6843ABGABLQ1
    Texas Instruments Single-chip 60-GHz to 64-GHz automotive radar sensor integrating DSP, MCU and radar accelerator 161-FCCSP -40 to 125 Visit Texas Instruments
    AWR1843ABGABLQ1
    Texas Instruments Single-chip 76-GHz to 81-GHz automotive radar sensor integrating DSP, MCU and radar accelerator 161-FC/CSP -40 to 125 Visit Texas Instruments Buy

    MAGNETRON RADAR Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    E3571

    Abstract: magnetron toshiba magnetron s band toshiba x-ray tube WR-90 power supply for magnetron toshiba magnetron magnetron* -coaxial sharp magnetron
    Contextual Info: Electron Tube, Device & Equipment TECHNICAL DATA MAGNETRON E 3 5 7 1 Toshiba magnetron E3571 is a fixed frequency pulsed type magnetron intended for use in radar systems of various kinds of ships, such as sail boats, and fishing boats. The peak output power is about 4 kW in


    OCR Scan
    E3571 WR-90 magnetron toshiba magnetron s band toshiba x-ray tube WR-90 power supply for magnetron toshiba magnetron magnetron* -coaxial sharp magnetron PDF

    x-band magnetron m1475A

    Abstract: M1475A M1475 x-band magnetron "25kw" magnetron* x-band DSA0048783 25kw Magnetron 2 kW
    Contextual Info: M1475A X-Band Magnetron M1475A is designed for the magnetron of x-band radar system. The frequency range is fixed <9345 – 9405MHz> and the peak output power is 25kw. - MAXIMUM RATINGS -Peak anode current Perk anode power input Duty cycle Pulse duration


    Original
    M1475A M1475A 9405MHz> x-band magnetron m1475A M1475 x-band magnetron "25kw" magnetron* x-band DSA0048783 25kw Magnetron 2 kW PDF

    MSF1425A

    Abstract: x-band magnetron magnetron 5kw radar magnetron X-band msf*1425 magnetron kw X-band magnetron* x-band
    Contextual Info: MSF1425A X-Band Magnetron MSF1425A is designed for the magnetron of x-band radar system. The frequency range is fixed <9345 - 9405MHz> and the peak output power is 10.5kW. - MAXIMUM RATINGS -Min 3.0 0.05 - Peak anode current Perk anode power input Duty cycle


    Original
    MSF1425A MSF1425A 9405MHz> x-band magnetron magnetron 5kw radar magnetron X-band msf*1425 magnetron kw X-band magnetron* x-band PDF

    JRC magnetron m5020

    Abstract: s-band magnetron jrc magnetron M5020 M1302 magnetron s-band kw s band jrc magnetron Magnetron 2 kW jrc radar magnetron magnetron s-band
    Contextual Info: M1302/M5020 S-Band Magnetron M1302/M5020 is designed for the magnetron of S-band radar system. The frequency range is fixed between 3.04GHz and 3.06GHz. The peak output power is 25kW Min. - MAXIMUM RATINGS -Min 6.0 - Max 12.0 100 0.001 1.0 130 Unit A


    Original
    M1302/M5020 M1302/M5020 04GHz 06GHz. JRC magnetron m5020 s-band magnetron jrc magnetron M5020 M1302 magnetron s-band kw s band jrc magnetron Magnetron 2 kW jrc radar magnetron magnetron s-band PDF

    jrc magnetron

    Abstract: MSF1425A jrc radar magnetron magnetron X-band Magnetron 2 kW magnetron magnetron 5kw radar system msf*1425 magnetron 10 kw
    Contextual Info: MSF1425A X-Band Magnetron MSF1425A is designed for the magnetron of X-band radar system. The frequency range is fixed between 9.345GHz and 9.405GHz. The peak output power is 12.5kW. - MAXIMUM RATINGS -Min 3.0 0.05 - Max 7.0 50 0.001 1.0 90 Unit A kW us


    Original
    MSF1425A MSF1425A 345GHz 405GHz. jrc magnetron jrc radar magnetron magnetron X-band Magnetron 2 kW magnetron magnetron 5kw radar system msf*1425 magnetron 10 kw PDF

    x-band magnetron

    Abstract: magnetron X-band microwave magnetron magnetrons Radar magnetron* x-band pulse magnetrons Radars magnetron kw
    Contextual Info: Magnetrons VMX 1805 Magnetron Description: Small, lightweight 4 kW, X-Band magnetron suitable for use in ground radars Features: • · · · · · · · · Frequency 9.5 – 9.7 GHz Peak Power Output 4 kW Duty Cycle .0012 Anode Voltage 4 kV Anode Current 3 amps


    Original
    PDF

    jrc radar magnetron

    Abstract: M1380 s-band coupler magnetron s-band kw Magnetron 2 kW magnetron s-band magnetron kw s-band s-band magnetron jrc magnetron
    Contextual Info: M1380 S-Band Magnetron M1380 is designed for the magnetron of S-band radar system. The frequency range is fixed between 3.025GHz and 3.075GHz. The peak output power is 50kW Min. - MAXIMUM RATINGS -Min 6.0 - Max 18.0 170 0.001 1.0 130 Unit A kW us kV/us


    Original
    M1380 M1380 025GHz 075GHz. jrc radar magnetron s-band coupler magnetron s-band kw Magnetron 2 kW magnetron s-band magnetron kw s-band s-band magnetron jrc magnetron PDF

    MSF1425B

    Abstract: msf*1425 magnetron 5kw magnetron kw Magnetron 2 kW
    Contextual Info: MSF1425B X-Band Magnetron MSF1425B is designed for the magnetron of x-band radar system. The frequency range is fixed <9380 - 9440MHz> and the peak output power is 10.5kW. - MAXIMUM RATINGS -Min 3.0 0.05 - Peak anode current Perk anode power input Duty cycle


    Original
    MSF1425B MSF1425B 9440MHz> msf*1425 magnetron 5kw magnetron kw Magnetron 2 kW PDF

    M1439

    Abstract: jrc magnetron jrc radar magnetron magnetron X-band Magnetron 1.5 kW magnetron 10 kw Magnetron 2 kW magnetron jrc
    Contextual Info: M1439 X-Band Magnetron M1439 is designed for the magnetron of X-band radar system. The frequency range is fixed between 9.415GHz and 9.475GHz. The peak output power is 1.0kW. - MAXIMUM RATINGS -Min 1.5 0.05 - Peak anode current Peak anode power input


    Original
    M1439 M1439 415GHz 475GHz. jrc magnetron jrc radar magnetron magnetron X-band Magnetron 1.5 kW magnetron 10 kw Magnetron 2 kW magnetron jrc PDF

    jrc magnetron

    Abstract: jrc radar magnetron x-band magnetron magnetron X-band M1528 9 Ghz magnetron Magnetron 1.5 kW magnetron s band magnetron* x-band m1528 x-band power transistor
    Contextual Info: M1528 X-Band Magnetron M1528 is designed for the magnetron of X-band radar system. The frequency range is fixed between 9.415GHz and 9.475GHz. The peak output power is 1.8kW. - MAXIMUM RATINGS -Min 1.5 0.05 - Peak anode current Peak anode power input


    Original
    M1528 M1528 415GHz 475GHz. jrc magnetron jrc radar magnetron x-band magnetron magnetron X-band 9 Ghz magnetron Magnetron 1.5 kW magnetron s band magnetron* x-band m1528 x-band power transistor PDF

    mg5353

    Abstract: X-band marine radar x-band magnetron JST VHR-2N E2V Technologies Magnetron 1.5 kW power supply for magnetron e2v magnetron power supply for x-band magnetron E2V Technologies magnetron
    Contextual Info: MG5353 1.5 kW X-Band Magnetron DESCRIPTION The MG5353 is a fixed frequency pulse magnetron for use in marine radar systems. The peak power output is typically 1.5 kW at a frequency between 9380 and 9440 MHz. This tube is one of e2v technologies’ range of third generation


    Original
    MG5353 MG5353 MG5353, X-band marine radar x-band magnetron JST VHR-2N E2V Technologies Magnetron 1.5 kW power supply for magnetron e2v magnetron power supply for x-band magnetron E2V Technologies magnetron PDF

    jrc magnetron

    Abstract: MSF1421C magnetron X-band jrc radar magnetron Magnetron 1.5 kW Magnetron 2 kW
    Contextual Info: MSF1421C X-Band Magnetron MSF1421C is designed for the magnetron of X-band radar system. The frequency range is fixed between 9.415GHz and 9.475GHz. The peak output power is 4.0kW. - MAXIMUM RATINGS -Min 2.0 0.05 - Max 4.0 30 0.001 1.0 70 Unit A kW us


    Original
    MSF1421C MSF1421C 415GHz 475GHz. jrc magnetron magnetron X-band jrc radar magnetron Magnetron 1.5 kW Magnetron 2 kW PDF

    magnetron wc

    Abstract: ZS90 RCA-7008 ax 3000 7008 magnetron magnetron ns magnetron 200 kw 6865-A tektronix tube sharp magnetron
    Contextual Info: 7008 MAGNETRON Integral Magnet Forced-Air Cooled Servo Tunable 8500-9600 Mc For Pulsed-Oscillator Service 220 Kw Peak Power Output TENTATIVE DATA RCA-7008 is a tunable magnetron intended for service as a pulsed oscillator at frequencies Electrical: between 8500 and 9600 megacycles per second.


    Original
    RCA-7008 062Er 92C5-5981R1 ZS-90 magnetron wc ZS90 ax 3000 7008 magnetron magnetron ns magnetron 200 kw 6865-A tektronix tube sharp magnetron PDF

    M1302A

    Abstract: jrc magnetron s-band magnetron jrc radar magnetron MAGNETRON m1302 magnetron s-band kw magnetron s-band jrc radar Magnetron 2 kW
    Contextual Info: M1302A S-Band Magnetron M1302A is designed for the magnetron of S-band radar system. The frequency range is fixed between 3.04GHz and 3.06GHz. The peak output power is 30kW Min. - MAXIMUM RATINGS -Min 6.0 - Max 12.0 100 0.001 1.0 130 Unit A kW us kV/us


    Original
    M1302A M1302A 04GHz 06GHz. jrc magnetron s-band magnetron jrc radar magnetron MAGNETRON m1302 magnetron s-band kw magnetron s-band jrc radar Magnetron 2 kW PDF

    Radar JRC 1000

    Abstract: Jrc 1000 Radar m5187 jrc magnetron x-band magnetron x-band magnetron "25kw" M1325
    Contextual Info: neUI J R C Tecinrorm , hn.icalauon m icROLURve d e v i c e s M1325L/M5187 X-Band Magnetron M1325L/M5187 is designed for the magnetron of x-band radar system.The frequency range is fixed <9380 ~ 9440MHz> and the peak output power is 25kW. MAXIMUM RATINGS -Min


    OCR Scan
    M1325L/M5187 9440MHz> UG-40 Radar JRC 1000 Jrc 1000 Radar m5187 jrc magnetron x-band magnetron x-band magnetron "25kw" M1325 PDF

    6kw magnetron

    Abstract: MAF1422B magnetron 6kw jrc magnetron
    Contextual Info: n e w JRC Technical Information mlCROLURVE D E V I C E S X-Band Magnetron MAF1422B is designed for the magnetron of x-band radar system.The freguency range is fixed ~9380-9440MHz> and the peak output power is 6kW. - MAXIMUM RATINGS - Peak anode current peak anode power input .


    Original
    MAF1422B 9380-9440MHz> 6kw magnetron magnetron 6kw jrc magnetron PDF

    Weather Radar

    Abstract: S-band magnetron 9 Ghz magnetron magnetron s-band kw magnetron VMS 1197B DOPPLER circuit magnetron doppler doppler radar magnetron kw s-band
    Contextual Info: Magnetrons VMS 1197B Magnetron Description: S-Band magnetron suitable for use in pulse doppler weather radars. Features: • · · · · · · · · · · Frequency 2.7 - 2.9 GHz Peak Power Output 750 kW min. Duty Cycle .0006 Anode Voltage 32 kV @ 60 amps Pulsewidth 4.0 mS


    Original
    1197B Weather Radar S-band magnetron 9 Ghz magnetron magnetron s-band kw magnetron VMS 1197B DOPPLER circuit magnetron doppler doppler radar magnetron kw s-band PDF

    x-band magnetron

    Abstract: magnetron X-band magnetron 200 magnetron 200 kw microwave magnetron Radar magnetron kw
    Contextual Info: Q 0UR JDWQH V VMX 1090 Magnetron Description: X-Band magnetron suitable for use in GCA and precision approach radars. Features: • Frequency 9.0 - 9.6 GHz · Peak Power Output 200 kW min. · Duty Cycle .001 · Anode Voltage 22 kV · Anode Current 28 A · Pulsewidth 0.18 and 2.35 mS


    Original
    PDF

    M1458A

    Abstract: x-band magnetron jrc radar magnetron magnetron valve JRC IC x-band magnetron "25kw" magnetron M1458A magnetron* x-band M1458A jrc magnetron
    Contextual Info: n e UJ JRC Technical In form ation micROUjnvE d e v i c e s M1458A X-Band Magnetron M145aA is designed for the magnetron of x-band radar system.The frequency range is fixed <9380 — 944QMHz> and the peak output power is 25kW. MAXIMUM RATINGS -Min Peak anode current- :— -6.0


    OCR Scan
    M1458A 944QMHz> UC-40 x-band magnetron jrc radar magnetron magnetron valve JRC IC x-band magnetron "25kw" magnetron M1458A magnetron* x-band M1458A jrc magnetron PDF

    MSF1422B

    Abstract: 6kw magnetron magnetron kw magnetron 65 kw Magnetron 1.5 kW
    Contextual Info: MSF1422B X-Band Magnetron MSF1422B is designed for the magnetron of x-band radar system. The frequency range is fixed <9380-9440MHz> and the peak output power is 6kW. - MAXIMUM RATINGS –-Peak anode current •··············· Perk anode power input ············


    Original
    MSF1422B MSF1422B 9380-9440MHz> 6kw magnetron magnetron kw magnetron 65 kw Magnetron 1.5 kW PDF

    magnetron toshiba

    Abstract: toshiba x-ray tube e3587 magnetron s band UG-136B UG-136 power supply for magnetron pacemaker magnetron WR-90
    Contextual Info: MAGNETRON E3587 T o s h ib a m a g n etro n E 3587 is a fix e d frequency pulsed type magnetron intended for use in radar systems of various kinds of ships, such as sail boats, and fishing boats. The peak output power is about 1.8 kW in the frequency range from 9380 to 9440 MHz.


    OCR Scan
    E3587 E3587 WR-90 magnetron toshiba toshiba x-ray tube magnetron s band UG-136B UG-136 power supply for magnetron pacemaker magnetron WR-90 PDF

    MAF1421B

    Abstract: MAF1421
    Contextual Info: MAF1421B X-Band Magnetron MAF1421B is designed for the magnetron of x-band radar system. The frequency range is fixed <9380-9440MHz> and the peak output power is 4kW. - MAXIMUM RATINGS -Peak anode current•················· Perk anode power input ·············


    Original
    MAF1421B MAF1421B 9380-9440MHz> MAF1421 PDF

    magnetron 200

    Abstract: KT 0803 KT 0803 K TA 2092 N 10S6 2X10 sharp modulateur tube cathodique philips magnetron
    Contextual Info: PHILIPS [”55008 Packaged MAGNETRON for use as pulsed oscillator at a fixed frequency In the 8 .6 mm band between the 34512 and 35208 Kc/s limits. It Is capable of delivering a peak output power of more than 60 kW at a peak anode current of 17.5 A The magnetron is designed for very short pulse operation


    OCR Scan
    55GGS magnetron 200 KT 0803 KT 0803 K TA 2092 N 10S6 2X10 sharp modulateur tube cathodique philips magnetron PDF

    M1516

    Abstract: magnetron 5kw radar system Magnetron 1.5 kW Magnetron 2 kW
    Contextual Info: M1516 X-Band Magnetron M1516 is designed for the magnetron of x-band radar system. The frequency range is fixed <9415-9475MHz> and the peak output power is 1.5kW. - MAXIMUM RATINGS -Peak anode current •················ Perk anode power input ·············


    Original
    M1516 M1516 9415-9475MHz> magnetron 5kw radar system Magnetron 1.5 kW Magnetron 2 kW PDF