NF RAILWAY STANDARDS SWITCH Search Results
NF RAILWAY STANDARDS SWITCH Result Highlights (5)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
DE6B3KJ221KN4AE01J | Murata Manufacturing Co Ltd | Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive |
![]() |
||
DE6E3KJ102MA4B | Murata Manufacturing Co Ltd | Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive |
![]() |
||
DE6E3KJ332MB4B | Murata Manufacturing Co Ltd | Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive |
![]() |
||
DE6B3KJ221KB4BE01J | Murata Manufacturing Co Ltd | Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive |
![]() |
||
DE6B3KJ681KN4AE01J | Murata Manufacturing Co Ltd | Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive |
![]() |
NF RAILWAY STANDARDS SWITCH Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
RADOX POWER CABLE
Abstract: RADOX 125 1.5 MM2 radox 125 current
|
Original |
||
RADOX CABLE 125
Abstract: RADOX 125 1.5 MM2 siemens standard bogie RADOX 125 1.5 MM SMA-50-3-55/199 11_SMA-50-3-55/199_NE RADOX CABLE
|
Original |
||
Contextual Info: Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.21 and CM-MPS.41 Characteristics –– Monitoring of three-phase mains for phase sequence can be switched off , phase failure, over- and undervoltage as well as phase unbalance –– TRMS measuring principle |
Original |
||
3 phase monitoring relaysContextual Info: Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. Characteristics –– Monitoring of three-phase mains for phase sequence and |
Original |
V0012 3 phase monitoring relays | |
Contextual Info: Data sheet Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages The CM-ESS.1 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of phase loss. Characteristics –– Monitoring of DC and AC voltages 3-600 V |
Original |
||
Contextual Info: Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of phase loss. Characteristics –– Monitoring of DC and AC voltages 3-600 V |
Original |
||
Contextual Info: Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that monitors single-phase mains DC or AC for over- and undercurrent from 3 mA to 15 A. Characteristics –– Monitoring of DC and AC currents (3 mA to 15 A) |
Original |
||
Contextual Info: www.martekpower.com MPF 3K0 1I01 DC/AC INVERTER >Description The 3kVA railway application inverter provides 230 VAC power to train passengers. It has an input of 110 VDC and an output of 230 VAC 50Hz. It is fan cooled and complies with railway standards EN 50155 and EN 50121-3-2. Its standard size facilitates its integration |
Original |
||
ABB STOTZ-KONTAKT S 211
Abstract: HC-49/ABB STOTZ-KONTAKT S 211
|
Original |
||
Contextual Info: IBX15 Series Data Sheet Boost Converters Features 54.9 2.16" 54.9 2.16" • • • • • • • • • • 11.5 0.45" RoHS compliant for all 6 substances Wide input voltage range 8 to 160 VDC Output: 30 to 80 VDC Class III equipment no isolation input/output |
Original |
IBX15 02-Dec-2013 | |
microcontroller based substation monitoring using
Abstract: microcontroller based overvoltage and under voltage relays microcontroller based overcurrent relay RTXP 24 microcontroller based substation monitoring and c railway DC feeder protection relay 614AA SUBSTATION CONTROL SYSTEM directional static overcurrent relay 2 pc 506
|
Original |
017-BEN SE970142) 003-BEN 017-USV 017-REN 014-BEN 034-BEN S-721 microcontroller based substation monitoring using microcontroller based overvoltage and under voltage relays microcontroller based overcurrent relay RTXP 24 microcontroller based substation monitoring and c railway DC feeder protection relay 614AA SUBSTATION CONTROL SYSTEM directional static overcurrent relay 2 pc 506 | |
QwikConnect October 2007Contextual Info: Qwik Connect G L E N A I R OCTOBER 2007 V O L U M E 11 N U M B E R Take The “A” Train! Glenair Has the Connectors, the Cables and the Expertise to Solve Even the Toughest Rail Industry Interconnect Challenges 4 QwikConnect Take the “A” Train: Connectors, Cables and World-Class Interconnect |
Original |
||
LWN2880-6Contextual Info: W Series Data Sheet 125, 250 Watt AC-DC and DC-DC DIN-Rail Converters Features • RoHS lead-free-solder and lead-solder-exempted products are available • Rugged 35 mm DIN-rail snap-fit design • Class I equipment • Universal AC-input or DC-input 66 – 150 or 90 – 350 VDC |
Original |
overl35-2 S-KSMH48-2 S-KSMH48-2-27-35-2 BCD20020-G 31-Jan-2013 LWN2880-6 | |
LWN1740-6EM1
Abstract: LWR1240-6EM1 SOC NT3 LWR1801-6E 501-2132 UL508-listed uhalp chloride systems 48v charger LWR1701-6E HZZ00618
|
Original |
PCB24-2 S-KSMH48-2 S-KSMH48-2-27-35-2 BCD20020-G 17-Nov-09 LWN1740-6EM1 LWR1240-6EM1 SOC NT3 LWR1801-6E 501-2132 UL508-listed uhalp chloride systems 48v charger LWR1701-6E HZZ00618 | |
|
|||
Technical DataContextual Info: Level Switch LFFS Special Features Wetted parts in acid-proof, stainless steel and PEEK Compact, food compatible, hygienic design Hygienic connections conform to 3-A standards, FDA demands and EHEDG guidelines Precise switching point without |
Original |
EN/2014-08-26 Technical Data | |
model railway signal project
Abstract: EN 61373 Category 1 Class B SOC NT3 battery charger for mobile 3.7 VDC ac-dc converter full wave type schematic diagram schematic diagram ac-dc converter full wave drossel capacitor LWN1801-6 drossel capacitor 16A HZZ00618
|
Original |
||
relay railway
Abstract: LWR-1601-6 NF railway standards switch LWN1601-6 48V AC-DC POWER CONVERTERS APPLICATION NOTES powerone 48v rectifier LWN1740-6EM1
|
Original |
BCD20020-G relay railway LWR-1601-6 NF railway standards switch LWN1601-6 48V AC-DC POWER CONVERTERS APPLICATION NOTES powerone 48v rectifier LWN1740-6EM1 | |
EN 61373 Category 1 Class BContextual Info: IMX4 Series Data Sheet 4 Watt DC-DC Converters Features • RoHS lead-free-solder and lead-solder-exempted products are available. • Input voltage ranges up to 121 VDC • 1 or 2 isolated outputs up to 48 V 20 0.8" • Extremely wide input voltage ranges |
Original |
BCD20006-G 15-Dec-2011 EN 61373 Category 1 Class B | |
EN 61373 Category 1 Class B
Abstract: 5imx4-05 20IMX4-1515-8 40imx4-05-8 40IMX4-2424-8ZG 20IMX4-1212-8 5IMX4-15-8
|
Original |
70IMX4 BCD20006-G 06-Jul-2012 EN 61373 Category 1 Class B 5imx4-05 20IMX4-1515-8 40imx4-05-8 40IMX4-2424-8ZG 20IMX4-1212-8 5IMX4-15-8 | |
Contextual Info: IMX4 Series Data Sheet 4 Watt DC-DC Converters Features • RoHS lead-free-solder and lead-solder-exempted products are available. • Input voltage ranges up to 121 VDC • 1 or 2 isolated outputs up to 48 V 20 0.8" • Extremely wide input voltage ranges |
Original |
BCD20006-G 06-Jul-2012 | |
40IMX4-15-8
Abstract: 40imx4-05-8 40IMX4-1212-8 40IMX4-05 20IMX4-12-8 40IMX4-2424-8 70IMX4-15-8 CI 3060 elsys Transient Voltage Suppressors 340 V 20IMX4-0505-8
|
Original |
70IMX4 89/336/EEC 40IMX4-15-8 40imx4-05-8 40IMX4-1212-8 40IMX4-05 20IMX4-12-8 40IMX4-2424-8 70IMX4-15-8 CI 3060 elsys Transient Voltage Suppressors 340 V 20IMX4-0505-8 | |
EN 61373 Category 1 Class B
Abstract: Antenna-10 20IMX4-05-8 40IMX4-05 40IMX4-05-8 40IMX4-15-8 20IMX4-03-8 h-890 diode 70IMX4-12-8
|
Original |
89/336/EEC BCD20006-G 8-Apr-09 EN 61373 Category 1 Class B Antenna-10 20IMX4-05-8 40IMX4-05 40IMX4-05-8 40IMX4-15-8 20IMX4-03-8 h-890 diode 70IMX4-12-8 | |
Contextual Info: Features ICE Technology* Description ● ● ● ● ● ● ● ● ● ● ● ● Tx Temperature Range without Derating 120°C Maximum Case Temperature -45°C Minimum Temp. EN 50155 Compliant EN 50121-3-2 Compliant CE Marked 24, 48 and 110VDC Input Ranges |
Original |
110VDC RPR50 24VDC 110VDC, RPR-39 RPR-40 | |
Contextual Info: Features ICE Technology* Description ● ● ● ● ● ● ● ● ● ● ● ● Tx Temperature Range without Derating 120°C Maximum Case Temperature -45°C Minimum Operating Temperature EN 50155 Compliant EN 50121-3-2 Compliant CE Marked 24, 48 and 110VDC Input Ranges |
Original |
110VDC RPR30 24VDC 110VDC, |