Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PRESSURE THALES Search Results

    PRESSURE THALES Result Highlights (2)

    Part ECAD Model Manufacturer Description Download Buy
    PGA300ARHHT
    Texas Instruments PGA300 Signal Conditioner and Transmitter for Pressure Sensors 36-VQFN -40 to 150 Visit Texas Instruments
    PGA300ARHHR
    Texas Instruments PGA300 Signal Conditioner and Transmitter for Pressure Sensors 36-VQFN -40 to 150 Visit Texas Instruments Buy

    PRESSURE THALES Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    thales

    Abstract: INDUSTRIAL RF HEATING
    Contextual Info: INDUSTRIAL RF HEATING ITK 350-1 Water cooled triode 1000 kW Output power: 1000 kW in CW mode Anode voltage: 22 kV Anode dissipation: 500 kW Frequency up to 30 MHz INDUSTRIAL RF HEATING T he ITK 350-1 is a high-power triode designed specifically for industrial


    Original
    PDF

    TRIODE itk 30

    Abstract: thales "Power Triode" TRIODE itk 15-2
    Contextual Info: INDUSTRIAL RF HEATING ITK 15-2 Water cooled triode 63 kW Output power: 63 kW in CW mode Anode voltage: 13 kV Anode dissipation: 20 kW Frequency up to 120 MHz INDUSTRIAL RF HEATING T he ITK 15-2 is a RF power triode designed specifically for industrial applications.


    Original
    PDF

    TRIODE itk 30

    Abstract: thales itk 30-2 ITK 30.2 "Power Triode" V1265 THALES tube electron cold TRIODE itk 30 2
    Contextual Info: INDUSTRIAL RF HEATING ITK 30-2 Water cooled triode 130 kW Output power: 130 kW in CW mode Anode voltage: 14 kV Anode dissipation: 50 kW Frequency up to 100 MHz INDUSTRIAL RF HEATING T he ITK 30-2 is a RF power triode designed specifically for industrial applications.


    Original
    PDF

    high power Triode

    Abstract: thales THALES tube "Power Triode" Power Triode application ITK 200 TRIODE itk 30
    Contextual Info: INDUSTRIAL RF HEATING ITK 90-1 Water cooled triode 240 kW Output power: 240 kW in CW mode Anode voltage: 17 kV Anode dissipation: 120 kW Frequency up to 100 MHz INDUSTRIAL RF HEATING T he ITK 90-1 is a RF power triode designed specifically for industrial applications.


    Original
    PDF

    ITK 12-1

    Abstract: TRIODE itk 30 thales ITK 2-1 Electron Tubes ITK 12.1 "Power Triode"
    Contextual Info: INDUSTRIAL RF HEATING ITK 12-1 Water cooled triode 40 kW Output power: 40 kW in CW mode Anode voltage: 12 kV Anode dissipation: 15 kW Frequency up to 120 MHz INDUSTRIAL RF HEATING T he ITK 12-1 is a RF power triode designed specifically for industrial applications.


    Original
    PDF

    ITK 60-2

    Abstract: TRIODE itk 30 thales THALES tube TRIODE itk 30 2 "Power Triode" electron cold INDUSTRIAL RF HEATING Thales Electron Devices
    Contextual Info: INDUSTRIAL RF HEATING ITK 60-2 Water cooled triode 180 kW Output power: 178 kW in CW mode Anode voltage: 14 kV Anode dissipation: 70 kW Frequency up to 30 MHz INDUSTRIAL RF HEATING T he ITK 60-2 is a RF power triode designed specifically for industrial applications.


    Original
    PDF

    ELECTRON TUBE 10

    Abstract: ITK 2-1 "Power Triode" thales INDUSTRIAL RF HEATING K1-AT TRIODE itk 2-1
    Contextual Info: INDUSTRIAL RF HEATING ITK 3-1 Water cooled triode 6.7 kW Output power: 6.7 kW in CW mode Anode voltage: 7.2 kV Anode dissipation: 3.5 kW Frequency up to 160 MHz INDUSTRIAL RF HEATING T he ITK 3-1 is a RF power triode designed specifically for industrial applications.


    Original
    PDF

    thales itk 5-1

    Abstract: pressure thales thales ITK 2-1 itk 5-1 triode TRIODE itk 5-1 P391 TRIODE itk 2-1
    Contextual Info: INDUSTRIAL RF HEATING ITK 5-1 Water cooled triode 13 kW Output power: 13 kW in CW mode Anode voltage: 7.2 kV Anode dissipation: 6 kW Frequency up to 150 MHz INDUSTRIAL RF HEATING T he ITK 5-1 is a RF power triode designed specifically for industrial applications.


    Original
    PDF

    THALES tube

    Abstract: thales TRIODE itk 30 "Power Triode" 71kW
    Contextual Info: INDUSTRIAL RF HEATING ITK 25-1 Water cooled triode 90 kW Output power: 90 kW in CW mode Anode voltage: 14 kV Anode dissipation: 50 kW Frequency up to 100 MHz INDUSTRIAL RF HEATING T he ITK 25-1 is a RF power triode designed specifically for industrial applications.


    Original
    PDF

    thales

    Abstract: "Power Triode" TRIODE itk 30 INDUSTRIAL RF HEATING
    Contextual Info: INDUSTRIAL RF HEATING ITK 70-2 Water cooled triode 195 kW Output power: 195 kW in CW mode Anode voltage: 15 kV Anode dissipation: 100 kW Frequency up to 100 MHz INDUSTRIAL RF HEATING T he ITK 70-2 is a RF power triode designed specifically for industrial applications.


    Original
    PDF

    itk 120-2

    Abstract: ITK120-2 ITK120-3 TRIODE itk 30 industrial air cooler thales itk 5-1
    Contextual Info: INDUSTRIAL RF HEATING ITK120-2 ITK120-3 Water cooled triode 425 kW Output power: 425 kW in CW mode Anode voltage: ITK 120-2: 18 kV ITK 120-3: 20 kV Anode dissipation: 150 kW Frequency up to 30 MHz INDUSTRIAL RF HEATING T he ITK 120-2 and the ITK 120-3 are


    Original
    ITK120-2 ITK120-3 itk 120-2 ITK120-2 ITK120-3 TRIODE itk 30 industrial air cooler thales itk 5-1 PDF

    TRIODE itk 30

    Abstract: thales ITK 200-1 thales itk 5-1 THALES tube ITK 200 ITK 200-3 kw 600 thales 845 triode 845 power Triode
    Contextual Info: INDUSTRIAL RF HEATING ITK 200-1 ITK 200-3 Water cooled triode 600 kW Output power: 588 kW in CW mode Anode voltage: ITK 200-1: 18 kV ITK 200-3: 20 kV Anode dissipation: 220 kW Frequency up to 30 MHz INDUSTRIAL RF HEATING T he ITK 200-1 and the ITK 200-3 are


    Original
    DP172 TRIODE itk 30 thales ITK 200-1 thales itk 5-1 THALES tube ITK 200 ITK 200-3 kw 600 thales 845 triode 845 power Triode PDF

    ctk 15 2 tube

    Abstract: ctk 25 4 tube THALES tube ctk 25 ctk 25 THALES tube ctk 15 thales THALES tube ctk 25 35 15 ctk 25 tube
    Contextual Info: INDUSTRIAL RF HEATING CTK 3-1 CTK 3-3 High-µ triodes 5 kW Output power : 5 kW in CW mode Anode voltage : 7.2 kV Anode dissipation : 3 kW Frequencies up to 160 MHz Water cooled INDUSTRIAL RF HEATING T he CTK 3-1 and CTK 3-3 are highpower, high-µ triodes designed


    Original
    PDF

    ctk 25 4 tube

    Abstract: ctk 15 2 tube THALES tube ctk 25 thales THALES tube ctk 25 triode ctk 5-1 ctk 25 35 15 THALES tube ctk 15
    Contextual Info: INDUSTRIAL RF HEATING CTK 5-1 CTK 5-2 High-µ triodes 10 kW Output power : 10 kW in CW mode Anode voltage : 7.2 kV Anode dissipation : 6 kW Frequencies up to 150 MHz Water cooled INDUSTRIAL RF HEATING T he CTK 5-1 and CTK 5-2 are highpower, high-µ triodes designed


    Original
    PDF

    RS3010CJ

    Abstract: 3010CJ "Power Triode" thales rs tube
    Contextual Info: INDUSTRIAL RF HEATING RS 3010 CJ Water-cooled triode 11 kW Output power: 11 kW in CW mode Anode voltage: 7.2 kV Anode dissipation: 5 kW max. Frequency up to 150 MHz INDUSTRIAL RF HEATING The RS 3010 CJ is a RF power triode designed specifically for industrial


    Original
    PDF

    RS3150CJ

    Abstract: triode rs 3150 cj "Power Triode" thales THALES tube a 3150 data sheet TRIODE P539 rs tube
    Contextual Info: INDUSTRIAL RF HEATING RS 3150 CJ Water-cooled triode 240 kW Output power: 240 kW in CW mode Anode voltage: 15 kV Anode dissipation: 100 kW max. Frequency up to 100 MHz INDUSTRIAL RF HEATING The RS 3150 CJ is a RF power triode designed specifically for industrial


    Original
    PDF

    rs3005cj

    Abstract: thales high power Triode transistor 3005 rs tube 78941
    Contextual Info: INDUSTRIAL RF HEATING RS 3005 CJ Water-cooled triode 6 kW Output power: 6 kW in CW mode Anode voltage: 7.2 kV Anode dissipation: 2.5 kW max. Frequency up to 160 MHz INDUSTRIAL RF HEATING The RS 3005 CJ is a RF power triode designed specifically for industrial


    Original
    PDF

    thales

    Abstract: THALES tube INDUSTRIAL RF HEATING high power Triode rs tube
    Contextual Info: INDUSTRIAL RF HEATING RS 3061 CJ Water-cooled high-µ triode 110 kW Output power: 110 kW in CW mode Anode voltage: 15 kV Anode dissipation: 50 kW max. Frequency up to 100 MHz INDUSTRIAL RF HEATING The RS 3061 CJ is a RF power high- amplification factor triode designed


    Original
    PDF

    "Power Triode"

    Abstract: thales p537 an 3080 3020p RF Heating thales p INDUSTRIAL RF HEATING rs tube THALES tube
    Contextual Info: INDUSTRIAL RF HEATING RS 3080 CJ Water-cooled triode 130 kW Output power: 130 kW in CW mode Anode voltage: 14 kV Anode dissipation: 60 kW max. Frequency up to 100 MHz INDUSTRIAL RF HEATING The RS 3080 CJ is a RF power triode designed specifically for industrial


    Original
    PDF

    "Power Triode"

    Abstract: A 3020 thales rs tube
    Contextual Info: INDUSTRIAL RF HEATING RS 3020 CJ Water-cooled triode 20 kW Output power: 20 kW in CW mode Anode voltage: 12 kV Anode dissipation: 20 kW max. Frequency up to 120 MHz INDUSTRIAL RF HEATING The RS 3020 CJ is a RF power triode designed specifically for industrial


    Original
    PDF

    rs 3021 cj

    Abstract: RS 3021 CJ Industrial RF Heating RS 3021 high power Triode RS 3021 C rs3021cj thales rs3021 rs tube 10A40A
    Contextual Info: INDUSTRIAL RF HEATING RS 3021 CJ Water-cooled high-µ triode 20 kW Output power: 20 kW in CW mode Anode voltage: 14 kV Anode dissipation: 20 kW max. Frequency up to 120 MHz INDUSTRIAL RF HEATING The RS 3021 CJ is a RF power high- amplification factor triode designed


    Original
    PDF

    rs 3026 cj

    Abstract: rs3026cj "Power Triode" 3026 rs tube
    Contextual Info: INDUSTRIAL RF HEATING RS 3026 CJ Water-cooled triode 32 kW Output power: 32 kW in CW mode Anode voltage: 12 kV Anode dissipation: 25 kW max. Frequency up to 120 MHz INDUSTRIAL RF HEATING The RS 3026 CJ is a RF power triode designed specifically for industrial


    Original
    PDF

    p521

    Abstract: p521 file rs tube rs 3027
    Contextual Info: INDUSTRIAL RF HEATING RS 3027 CJ Water-cooled high-µ triode 32 kW Output power: 32 kW in CW mode Anode voltage: 14 kV Anode dissipation: 25 kW max. Frequency up to 120 MHz INDUSTRIAL RF HEATING The RS 3027 CJ is a RF power high- amplification factor triode designed


    Original
    char100 p521 p521 file rs tube rs 3027 PDF

    rs3300cj

    Abstract: THALES tube Triode 35C60 ELECTRON TUBE 10 448KW rs tube
    Contextual Info: INDUSTRIAL RF HEATING RS 3300 CJ Water-cooled triode 450 kW Output power: 450 kW in CW mode Anode voltage: 17 kV Anode dissipation: 150 kW max. Frequency up to 30 MHz INDUSTRIAL RF HEATING The RS 3300 CJ is a RF power triode designed specifically for industrial


    Original
    PDF