PULSE TRANSFORMER VAC Search Results
PULSE TRANSFORMER VAC Result Highlights (5)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
TPD4162F |
![]() |
Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=600 V / Iout=0.7 A / HSSOP31 |
![]() |
||
TPD4207F |
![]() |
Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=600 V / Iout=5 A / SSOP30 |
![]() |
||
TPD4164K |
![]() |
Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=600 V / Iout=2 A / HDIP30 |
![]() |
||
TPD4204F |
![]() |
Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=600 V / Iout=2.5 A / SSOP30 |
![]() |
||
TPD4206F |
![]() |
Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=500 V / Iout=2.5 A / SSOP30 |
![]() |
PULSE TRANSFORMER VAC Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
Pulse Transformer VAC
Abstract: VAC PULSE TRANSFORMER
|
OCR Scan |
IEEE802 10BASE-T. 111BHD HIM-3T201 10kHz] 100MHz] 3000/reel Pulse Transformer VAC VAC PULSE TRANSFORMER | |
spice TRANSFORMER simulation
Abstract: TM9921
|
Original |
TM9921 2795M spice TRANSFORMER simulation TM9921 | |
2779A
Abstract: 2664F 2741P2 Pulse Transformer VAC
|
Original |
TM00105 2664F, T1-12 2779A 2664F 2741P2 Pulse Transformer VAC | |
tm001
Abstract: TM0010 2779A Pulse Transformer VAC
|
Original |
TM00107 2664F, 2741P2, T1-16 tm001 TM0010 2779A Pulse Transformer VAC | |
2779A
Abstract: 2664F 2741P2 Pulse Transformer VAC
|
Original |
TM00107 2664F, 2741P2, T1-16 2779A 2664F 2741P2 Pulse Transformer VAC | |
Pulse Transformer VAC
Abstract: VAC PULSE TRANSFORMER tm001 2745R2
|
Original |
TM00106 T1-14 Pulse Transformer VAC VAC PULSE TRANSFORMER tm001 2745R2 | |
2741N2Contextual Info: HIGH FREQUENCY MAGNETICS Specialty Through Hole Shielded Transformer • TM00104 Operates as high frequency pulse transformer or as high frequency analog transformer in various telecom circuits requiring high voltage-step-up ratio • Operating Temperature Range: -40° C to +85° C |
Original |
TM00104 T1-10 2741N2 | |
Pulse Transformer VACContextual Info: HIGH FREQUENCY MAGNETICS Specialty Surface Mount Shielded Transformer • Operates as high frequency pulse transformer in telecom switching systems at various signaling rates • Interwinding Electrostatic Shield provides low capacitance and high EMI suppression |
Original |
TM00108 2741L2, 2779D 2779D T1-18 Pulse Transformer VAC | |
Pulse Transformer VAC
Abstract: VAC PULSE TRANSFORMER 2779D 2741L2
|
Original |
TM00108 2741L2, 2779D T1-18 Pulse Transformer VAC VAC PULSE TRANSFORMER 2779D 2741L2 | |
2741L2
Abstract: 2779D TM001
|
Original |
TM00103 2779D 2741L2 2779D TM001 | |
Pulse Transformer VAC
Abstract: VAC PULSE TRANSFORMER TRANSFORMER 71 TURNS RATIO 2664G transformer
|
Original |
TM00102 Pulse Transformer VAC VAC PULSE TRANSFORMER TRANSFORMER 71 TURNS RATIO 2664G transformer | |
Contextual Info: Pulse Transformer with Single Secondary Winding Pulse Transformers IT series Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Approvals Ignition current up to 3 A Turns ratio up to 3:1 IT pulse transformers are designed to offer you |
Original |
||
Contextual Info: Pulse Transformer with Single Secondary Winding Pulse Transformers IT series Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Approvals Ignition current up to 3 A Turns ratio up to 3:1 IT pulse transformers are designed to offer you |
Original |
||
Contextual Info: Pulse Transformer with Single Secondary Winding Pulse Transformers IT series Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Approvals Ignition current up to 3 A Turns ratio up to 3:1 IT pulse transformers are designed to offer you |
Original |
||
|
|||
Contextual Info: Pulse Transformer with Single Secondary Winding Pulse Transformers IT series Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Approvals Ignition current up to 3 A Turns ratio up to 3:1 IT pulse transformers are designed to offer you |
Original |
||
Contextual Info: DATASHEET Pulse Transformers IT series Pulse Transformer with Single Secondary Winding Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Approvals Ignition current up to 3 A Turns ratio up to 3:1 IT pulse transformers are designed to offer you |
Original |
||
Contextual Info: DATASHEET Pulse Transformers IT series Pulse Transformer with Single Secondary Winding Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Approvals Ignition current up to 3 A Turns ratio up to 3:1 IT pulse transformers are designed to offer you |
Original |
||
Contextual Info: Pulse Transformer with Single Secondary Winding Pulse Transformers IT series Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Approvals Ignition current up to 3 A Turns ratio up to 3:1 IT pulse transformers are designed to offer you |
Original |
||
Contextual Info: IX Pulse Transformers www.schurter.com/PG85 Cost optimized pulse transformer for THT mounting, up to 2W Description - High insulation rating >2.2 kVAC between the primary and the secondary windings - Small coupling capacitances between primary and secondary windings |
Original |
com/PG85 IX-30-0001 IX-30-0002 | |
Contextual Info: IX Pulse Transformers www.schurter.com/pg85 Cost optimized pulse transformer for THT mounting, up to 2W Description - High insulation rating >2.2 kVAC between the primary and the secondary windings - Small coupling capacitances between primary and secondary windings |
Original |
com/pg85 500VAC IX-30-0001 | |
Contextual Info: IX Pulse Transformers www.schurter.com/pg85 Cost optimized pulse transformer for THT mounting, up to 2W Description - High insulation rating >2.2 kVAC between the primary and the secondary windings - Small coupling capacitances between primary and secondary windings |
Original |
com/pg85 IX-30-0001 IX-30-0002 | |
Contextual Info: IX Pulse Transformers www.schurter.com/pg85 Cost optimized pulse transformer for THT mounting, up to 2W Description - High insulation rating >2.2 kVAC between the primary and the secondary windings - Small coupling capacitances between primary and secondary windings |
Original |
com/pg85 IX-30-0001 IX-30-0002 | |
Contextual Info: IX Pulse Transformers www.schurter.com/PG85 Cost optimized pulse transformer for THT mounting, up to 2W Description - High insulation rating >2.2 kVAC between the primary and the secondary windings - Small coupling capacitances between primary and secondary windings |
Original |
com/PG85 IX-30-0001 IX-30-0002 | |
Contextual Info: IX Pulse Transformers www.schurter.com/pg85 Cost optimized pulse transformer for THT mounting, up to 2W Description - High insulation rating >2.2 kVAC between the primary and the secondary windings - Small coupling capacitances between primary and secondary windings |
Original |
com/pg85 IX-30-0001 IX-30-0002 |