Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    RELAY OMRON 1N Search Results

    RELAY OMRON 1N Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    UHD432R/B Rochester Electronics LLC UHD432 - Quad 2-Input NOR Power/Relay Driver Visit Rochester Electronics LLC Buy
    DRV777DR Texas Instruments 7-bit Integrated Motor and Relay Driver 16-SOIC -40 to 125 Visit Texas Instruments Buy
    ULN2003LVDR Texas Instruments Low Power 3.3V & 5V Relay Driver 16-SOIC -40 to 85 Visit Texas Instruments Buy
    DS3680D Texas Instruments Quad Telephone Relay Drivers 14-SOIC 0 to 70 Visit Texas Instruments Buy
    ULN2003LVPWR Texas Instruments Low Power 3.3V & 5V Relay Driver 16-TSSOP -40 to 85 Visit Texas Instruments Buy

    RELAY OMRON 1N Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    OMRON plc sp16 manual

    Abstract: SP10-PRO01-V1 sp2038 SP10-CN221 OMRON plc programming console manual SP20-DRA SP10-PR001-V1 D14908 HMC-ES141 SP10-AL001
    Text: Issued March1993 D14908 RS Omron SP intelligent relay The Omron SP intelligent relay series combines the simplicity of conventional relay control with the sophistication of PLCs to provide a control device which is small, fast and very easy to use. Intelligent


    Original
    PDF March1993 D14908 110/240Vac 24Vdc OMRON plc sp16 manual SP10-PRO01-V1 sp2038 SP10-CN221 OMRON plc programming console manual SP20-DRA SP10-PR001-V1 D14908 HMC-ES141 SP10-AL001

    SP10-CN221

    Abstract: SP10-PRO01-V1 HMC-ES141 SP10-PR001-V1 OMRON plc sp16 manual basic plc ladder diagram SP16-DRA OMRON plc sp10 manual SP10-DRA SP20-DRA
    Text: Issued March1993 014-908 Data Pack D Data Sheet RS Omron SP intelligent relay The Omron SP intelligent relay series combines the simplicity of conventional relay control with the sophistication of PLCs to provide a control device which is small, fast and very easy to use. Intelligent relays are


    Original
    PDF March1993 110/240Vac 24Vdc SP10-CN221 SP10-PRO01-V1 HMC-ES141 SP10-PR001-V1 OMRON plc sp16 manual basic plc ladder diagram SP16-DRA OMRON plc sp10 manual SP10-DRA SP20-DRA

    SP10-CN221

    Abstract: SP10-PR001-V1 SP20-DRA SP10-PRO01-V1 SP16-DRA OMRON ladder diagram SP10-AL001 OMRON plc programming console manual OMRON plc sp10 manual PLC based temperature control ladder logic diagram
    Text: Issued March1997 232-3917 Data Pack D Data Sheet RS Omron SP intelligent relay The Omron SP intelligent relay series combines the simplicity of conventional relay control with the sophistication of PLCs to provide a control device which is small, fast and very easy to use. Intelligent relays are


    Original
    PDF March1997 110/240Vac 24Vdc SP10-CN221 SP10-PR001-V1 SP20-DRA SP10-PRO01-V1 SP16-DRA OMRON ladder diagram SP10-AL001 OMRON plc programming console manual OMRON plc sp10 manual PLC based temperature control ladder logic diagram

    SP10-PR001-V1

    Abstract: SP16-DRA SP20-DRA basic plc ladder diagram atm226 OMRON plc programming console manual SP16-dr-a OMRON highspeed counter example programs SP10-CN221 Circuit Diagram for 5vdc Relay Control Module
    Text: Issued July 1999 232-3917 Data Pack D Data Sheet RS Omron SP intelligent relay The Omron SP intelligent relay series combines the simplicity of conventional relay control with the sophistication of PLCs to provide a control device which is small, fast and very easy to use. Intelligent relays are


    Original
    PDF 110/240Vac 24Vdc SP10-PR001-V1 SP16-DRA SP20-DRA basic plc ladder diagram atm226 OMRON plc programming console manual SP16-dr-a OMRON highspeed counter example programs SP10-CN221 Circuit Diagram for 5vdc Relay Control Module

    Untitled

    Abstract: No abstract text available
    Text: Single-phase Voltage Relay K8AB-VW Ideal for voltage monitoring for industrial facilities and equipment. • Monitor for overvoltages and undervoltages simultaneously. Separate settings and outputs supported for overvoltages and undervoltages. • Manual resetting and automatically resetting supported by one


    Original
    PDF N144-E1-02

    Untitled

    Abstract: No abstract text available
    Text: Single-phase Current Relay K8AK-AS Ideal for Current Monitoring for Industrial Facilities and Equipment. • Monitor for overcurrents or undercurrents. • Use commercially available CTs CT current on secondary side: 0 to 1 A or 0 to 5 A . • Manual resetting and automatically resetting supported by one


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Single-phase Voltage Relay K8AK-VS Ideal for Voltage Monitoring for Industrial Facilities and Equipment. • Monitor for overvoltages or undervoltages. • Manual resetting and automatically resetting supported by one Relay. • One SPDT output relay, 5 A at 250 VAC resistive load .


    Original
    PDF

    AWG16

    Abstract: AWG18 IEC60947-1 K8AB IEC60947-3 omron power loss relay
    Text: Phase-sequence Phase-loss Relay K8AB-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method • Prevents reverse motor rotation due to incorrect wiring. • Distinguishes between positive phases, reversed phases, and phase loss when power is turned ON.


    Original
    PDF N145-E1-02 AWG16 AWG18 IEC60947-1 K8AB IEC60947-3 omron power loss relay

    omron 24vdc relay

    Abstract: AWG16 AWG18 K8AC-CT200L
    Text: Single-phase Current Relay K8AB-AS Ideal for current monitoring for industrial facilities and equipment. • Monitor for overcurrents or undercurrents. • Manual resetting and automatically resetting supported by one Relay. • Startup lock and operating time can be set separately.


    Original
    PDF N142-E1-02 omron 24vdc relay AWG16 AWG18 K8AC-CT200L

    Untitled

    Abstract: No abstract text available
    Text: Single-phase Overvoltage/Undervoltage Relay K8AK-VW Ideal for Voltage Monitoring for Industrial Facilities and Equipment. • Monitor for overvoltages and undervoltages simultaneously. Separate settings and outputs supported for overvoltages and undervoltages.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Single-phase Current Relay K8AK-AS Ideal for current monitoring for industrial facilities and equipment. • Monitor for overcurrents or undercurrents. • Use commercially available CTs CT current on secondary side: 0 to 1 A or 0 to 5 A . • Manual resetting and automatically resetting supported by one


    Original
    PDF NL-2132 N22I-E-01

    AWG16

    Abstract: AWG18
    Text: Single-phase Voltage Relay K8AB-VS Ideal for voltage monitoring for industrial facilities and equipment. • Monitor for overvoltages or undervoltages. • Manual resetting and automatically resetting supported by one Relay. • One SPDT output relay, 6 A at 250 VAC resistive load .


    Original
    PDF N143-E1-02 AWG16 AWG18

    Untitled

    Abstract: No abstract text available
    Text: Single-phase Overvoltage/Undervoltage Relays K8AK-VW Ideal for voltage monitoring for industrial facilities and equipment. • Monitor for overvoltages and undervoltages simultaneously. Separate settings and outputs supported for overvoltages and undervoltages.


    Original
    PDF NL-2132 N25I-E-01

    Untitled

    Abstract: No abstract text available
    Text: New Product Three-phase Undervoltage and Phase-sequence Phase-loss Relay K8DS-PU Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. • Greater resistance to inverter noise. • Monitor undervoltages, phase sequence, and phase loss in threephase three-wire circuits with one unit.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Single-phase Overcurrent/Undercurrent Relay K8AK-AW Ideal for Current Monitoring for Industrial Facilities and Equipment. • Monitor for overcurrents and undercurrents simultaneously. Separate settings and outputs supported for overcurrents and undercurrents.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Phase-sequence Phase-loss Relay K8AK-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method • Greater resistance to inverter noise. • Distinguishes between correct phases, phase sequence, and phase loss when power is turned ON. • Supports phase loss detection when the motor is operating.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: New Product Single-phase Current Relay K8AB-AS Ideal for current monitoring for industrial facilities and equipment. • Monitor for overcurrents or undercurrents. • Manual resetting and automatically resetting supported by one Relay. • Startup lock and operating time can be set separately.


    Original
    PDF 2356-81-300/Fax: 847-843-7900/Fax: 6835-3011/Fax: 21-5037-2222/Fax: N142-E1-03

    OMRON H3Y-2 TIMER

    Abstract: Omron RELAY RD2P H3Y-4 timer omron rd2p omron H3y-2 OMRON RD2P H3Y-4 time relay h3y-4 OMRON RELAY H3Y2 OMRON TIMER
    Text: Solid-state Timer H3Y Miniature Timer Compatible with the MY Relay • Semi-multi power supply voltage. • Large transparent time setting knob facilitates time setting. A flat-blade and Phillips screwdriver can also be used for time setting. • Pin configuration compatible with MY Power Relay.


    Original
    PDF EN61812-1 OMRON H3Y-2 TIMER Omron RELAY RD2P H3Y-4 timer omron rd2p omron H3y-2 OMRON RD2P H3Y-4 time relay h3y-4 OMRON RELAY H3Y2 OMRON TIMER

    Untitled

    Abstract: No abstract text available
    Text: New Product Phase-sequence Phase-loss Relay K8DS-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method • Lineup includes a 17.5-mm slim, compact model. • Greater resistance to inverter noise. • Distinguishes between correct phases, phase sequence, and phase


    Original
    PDF

    sv 120 115 relays

    Abstract: No abstract text available
    Text: Single-phase Current Relay K8AB-AS CSM_K8AB-AS_DS_E_3_1 Ideal for current monitoring for industrial facilities and equipment. • Monitor for overcurrents or undercurrents. • Manual resetting and automatically resetting supported by one Relay. • Startup lock and operating time can be set separately.


    Original
    PDF

    K8AC-CT200L

    Abstract: transformer ct K8ACCT200L HOW TO CONVERT DC CURRENT TO AC CURRENT 50 HZ omron k8ab-as2 CT200 K8AC-CT200 AWG16 AWG18 autotransformer motor wiring diagram
    Text: Single-phase Current Relay K8AB-AS CSM_K8AB-AS_DS_E_5_1 Ideal for current monitoring for industrial facilities and equipment. • Monitor for overcurrents or undercurrents. • Manual resetting and automatically resetting supported by one Relay. • Startup lock and operating time can be set separately.


    Original
    PDF

    omron power loss relay

    Abstract: No abstract text available
    Text: Three-phase Voltage and Phase-sequence Phase-loss Relay K8AK-PM Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. • Greater resistance to inverter noise. • Monitor overvoltages, undervoltages, phase sequence, and phase loss for three-phase 3-wire or 4-wire power


    Original
    PDF

    E41643

    Abstract: R99-04
    Text: General Purpose Relay G7J • Ideal for 3-phase motor control applications and resistive and inductive loads. • No contact chattering for momentary voltage drops up to 50% of rated voltage. • Withstands more than 4 kV between contacts that are of different polarity and between the coil and contacts.


    Original
    PDF UL94V-0) omron247 X301-E-01A E41643 R99-04

    OMRON H3DE-M1

    Abstract: omron H3DE-M2 H3DE-M1 H3DE-S2 omron h3de omron h3de-s2 transformerless power supply 12 volt 1A omron H3DR omron relay G2R H3DE-M2
    Text: omRon Solid-state Multi-functional Timer H3DE-M/-S • Eight operating modes H 3D E-M and four operating modes (H 3D E-S) cover a wide range of applications. ■ Programmable contact enables the building of a self-holding relay circuit (-D 2 models). ■ A wide time setting range of 0.10 s to 120 h.


    OCR Scan
    PDF