    Contextual Info: CCD231-C6 Back Illuminated Scientific CCD Sensor 6144 x 6160 Pixels, Four Outputs Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging


    Original
    CCD231-C6 CCD231 A1A-777755 PDF

    Contextual Info: CCD231-84 Back Illuminated Scientific CCD Sensor 4096 x 4096 Pixels, Four Outputs, Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging


    Original
    CCD231-84 CCD231 A1A-765136 PDF

    Glenair micro

    Abstract: CCD231 CCD230 GE-56
    Contextual Info: CCD231-84 Back Illuminated Scientific CCD Sensor 4096 x 4096 Pixels, Four Outputs Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging


    Original
    CCD231-84 CCD231 A1A-765136 Glenair micro CCD230 GE-56 PDF

    Contextual Info: CCD230-84 Scientific CCD Sensor Front Illuminated, 4096 x 4096 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. The low


    Original
    CCD230-84 CCD230 A1A-100049 PDF

    CCD230-84

    Abstract: Fenwal NTC 196-LAD302-002 CCD230 CCD231 4096H H2E1 capacitive readout circuit
    Contextual Info: CCD230-84 Scientific CCD Sensor Front Illuminated, 4096 x 4096 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. The low


    Original
    CCD230-84 CCD230 A1A-100049, Fenwal NTC 196-LAD302-002 CCD231 4096H H2E1 capacitive readout circuit PDF

    CCD230

    Abstract: CCD230-42
    Contextual Info: CCD230-42 Front Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. The low


    Original
    CCD230-42 CCD230 A1A-765137 PDF

    CCD230-42

    Contextual Info: CCD230-42 Front Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. The low


    Original
    CCD230-42 CCD230 A1A-765137 PDF

    Contextual Info: CCD231-84 Back Illuminated Scientific CCD Sensor 4096 x 4096 Pixels, Four Outputs Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging


    Original
    CCD231-84 CCD231 A1A-765136 PDF

    tri linear CCD

    Abstract: Glenair micro CCD230 CCD231
    Contextual Info: CCD231-84 Back Illuminated Scientific CCD Sensor 4096 x 4096 Pixels, Four Outputs, Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging


    Original
    CCD231-84 CCD231 A1A-765136 tri linear CCD Glenair micro CCD230 PDF

    Contextual Info: CCD230-84 Scientific CCD Sensor Back Illuminated, 4096 x 4096 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low readout


    Original
    CCD230-84 CCD230 A1A-764199 PDF

    196-LAD302-002

    Contextual Info: CCD230-84 Scientific CCD Sensor Back Illuminated, 4096 x 4096 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low readout


    Original
    CCD230-84 CCD230 A1A-764199 196-LAD302-002 PDF

    CCD230-42

    Abstract: ccd sensor back illuminated ccd231 common rail CCD230
    Contextual Info: CCD230-42 Back Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low read-out


    Original
    CCD230-42 CCD230 A1A-765138 ccd sensor back illuminated ccd231 common rail PDF

    CCD230

    Abstract: CCD230-42
    Contextual Info: CCD230-42 Back Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low read-out


    Original
    CCD230-42 CCD230 A1A-765138 PDF

    CCD230-42

    Contextual Info: CCD230-42 Back Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low read-out


    Original
    CCD230-42 CCD230 A1A-765138 PDF

    Contextual Info: R Digital CMOS camera C11440-10C Technical Note April 2015 1. Introduction P3 2. Scientific CMOS Image Sensor FL-280 P3 2.1. CCD image sensor vs. Scientific CMOS Image Sensor FL-280 2.1.1. Structure of CCD image sensor and CMOS image sensor 2.1.2. CCD image sensor vs. conventional CMOS image sensor


    Original
    C11440-10C FL-280 B1201 SCAS0070E02 APR/2015 PDF

    3D scanner

    Abstract: Piezo Electric pzt Piezo Ceramic plates
    Contextual Info: Agilent 5420 SPM/AFM Microscope Data Sheet Introducing The Agilent Technologies 5420 Scanning Probe Microscope SPM Features and Benefits • Scientific-grade instrument delivers atomic resolution • New design provides improved performance • New electronics and techniques


    Original
    5990-3848EN 3D scanner Piezo Electric pzt Piezo Ceramic plates PDF

    HADC674Z

    Abstract: HI674A
    Contextual Info: HADC674Z @ SPT FAST, COMPLETE 12-BIT COMPATIBLE A/D CONVERTER WITH SAMPLE/HOLD SIGNAL PROCESSING TECHNOLOGIES APPLICATIONS FEATURES Military/Industrial Data Acquisition Systems 8 or 12-Bit J.P Input Functions Process Control Systems Test and Scientific Instruments


    OCR Scan
    HADC674Z 12-BIT HI674A 12-Bit HADC674Z HI674A. DBO-DB11 HI674A PDF

    Contextual Info: Keysight Technologies N9320B Spectrum Analyzer The Most Cost-effective RF Measurement Instrument for the Manufacture of Consumer Wireless Electronics Introduction Since the Industrial, Scientific and Medical ISM 2.4 GHz frequency band is the most universal, unlicensed RF band


    Original
    N9320B BP-09-23-14) E3632A 4401A 5989-8798EN PDF

    SM2327-47

    Abstract: gaas amplifier
    Contextual Info: Specification Sheet for SM2327-47 SSPA This solid state GaAs amplifier is designed for Industrial, Scientific, Medical band market. By using the latest surface mount technologies, this small amplifier can easily fit into tightly packed transmitters and repeaters.


    Original
    SM2327-47 SM2327-47 com/specs/2325-47/2325 gaas amplifier PDF

    Contextual Info: BCN168RB summary material content, BI Technologies Corporation 6/21/06 Average mass of BCN168RB array is 0.007 grams each. Scientific notation is used for all component masses. Homogeneous Material Location Homogeneous Material Name Substrate Alumina Thick film


    Original
    BCN168RB 123E-2 123E-03 000E-05 330E-04 200E-05 000E-06 PDF

    Contextual Info: Agilent 5420 SPM/AFM Microscope Data Sheet Introducing The Agilent Technologies 5420 Scanning Probe Microscope SPM Features and Benefits • Scientific-grade instrument delivers high resolution • New design provides improved performance • New electronics and techniques


    Original
    5990-3848EN PDF

    Contextual Info: BCN218SBI summary material content, BI Technologies Corporation 6/21/06 Average mass of BCN218SBI array is 0.017 grams each. Scientific notation is used for all component masses. Homogeneous Material Location Substrate Thick film Termination Homogeneous Material Name Material name


    Original
    BCN218SBI 459E-02 680E-04 160E-04 300E-05 530E-04 000E-06 000E-07 PDF

    Contextual Info: BCN4D summary material content, BI Technologies Corporation 6/21/06 Average mass of BCN4D array is 0.028 grams each. Scientific notation is used for all component masses. Homogeneous Material Location Substrate Thick film Termination Homogeneous Material Name Material name


    Original
    455E-02 830E-04 320E-04 900E-05 630E-04 400E-05 200E-05 000E-06 600E-05 100E-05 PDF

    Contextual Info: BCN164A summary material content, BI Technologies Corporation 6/21/06 Average mass of BCN164A array is 0.007 grams each. Scientific notation is used for all component masses. Homogeneous Material Location Substrate Thick film Termination Homogeneous Material Name Material name


    Original
    BCN164A 723E-03 600E-05 240E-04 100E-05 400E-05 000E-06 100E-07 PDF