t2500
Abstract: t25000 of relay
Text: Protection Relays Generator Protection–Overcurrent/Short-Circuit T2500 Series Overcurrent and Short-Circuit Relay Description The combined T2500 3-Phase Overcurrent and Short-Circuit Relay is used for protection of generators and power transmissions. The short-circuit relay protects against faults
|
Original
|
PDF
|
T2500
com/t2500
t25000
of relay
|
Untitled
Abstract: No abstract text available
Text: Protection Relays Generator Protection–Overcurrent/Short-Circuit T2500 SERIES Overcurrent and Short-Circuit Relay Description The combined T2500 3-Phase Overcurrent and Short-Circuit Relay is used for protection of generators and power transmissions. The short-circuit relay protects against faults
|
Original
|
PDF
|
T2500
T2500
EN50081-1,
EN50082-1,
EN50081-2,
EN50082-2
com/t2500
|
Untitled
Abstract: No abstract text available
Text: Protection Relays Generator Protection–3-Phase Short-Circuit T2300 SERIES 3-Phase Short-Circuit Relay Description The T2300 3 Phase Short-Circuit Relay is designed for protection of generators, power transmissions and consumer’s supply against short circuit. The T2300 reacts on
|
Original
|
PDF
|
T2300
EN50081-1,
EN50082-1,
EN50081-2,
EN50082-2
|
T2300
Abstract: 15 V 1A 50 VA relay
Text: Protection Relays Generator Protection–3-Phase Short-Circuit T2300 Series 3-Phase Short-Circuit Relay Description The T2300 3 Phase Short-Circuit Relay is designed for protection of generators, power transmissions and consumer’s supply against short circuit. The T2300 reacts on
|
Original
|
PDF
|
T2300
EN50081-1,
EN50082-1,
EN50081-2,
EN50082-2
15 V 1A 50 VA relay
|
Untitled
Abstract: No abstract text available
Text: Protection Relays & Controls Generator & Single-Function Protection–3-Phase Short-Circuit T2300 SERIES 3-Phase Short-Circuit Relay Description The T2300 3 Phase Short-Circuit Relay is designed for protection of generators, power transmissions and consumer’s supply against short circuit. The T2300 reacts on
|
Original
|
PDF
|
T2300
EN50081-1,
EN50082-1,
EN50081-2,
EN50082-2
4-B-111014
|
Untitled
Abstract: No abstract text available
Text: Protection Relays & Controls Generator & Single-Function Protection–3-Phase Short-Circuit T2300 Series 3-Phase Short-Circuit Relay Description The T2300 3 Phase Short-Circuit Relay is designed for protection of generators, power transmissions and consumer’s supply against short circuit. The T2300 reacts on
|
Original
|
PDF
|
T2300
EN50081-1,
EN50082-1,
EN50081-2,
EN50082-2
|
Untitled
Abstract: No abstract text available
Text: GU SOP 1 Form A Short Circuit Protection AQY210KS TESTING Small SOP4-pin type with short circuit protecting (Latch type) 4.3 .169 4.4 .173 2.1 .083 mm inch 1 4 2 3 GU SOP 1 Form A Short Circuit Protection (AQY210KS) FEATURES TYPICAL APPLICATIONS 1. Short circuit protection (Latch type)
|
Original
|
PDF
|
AQY210KS)
120mA
ASCTB27E
201201-T
|
AQY210
Abstract: AQY210KS AQY210KSX AQY210KSZ
Text: GU SOP 1 Form A Short Circuit Protection AQY210KS TESTING Small SOP4-pin type with short circuit protecting (Latch type) 4.3 .169 4.4 .173 2.1 .083 mm inch 1 4 2 3 GU SOP 1 Form A Short Circuit Protection (AQY210KS) FEATURES TYPICAL APPLICATIONS 1. Short circuit protection (Latch type)
|
Original
|
PDF
|
AQY210KS)
120mA
aqy210ks:
140509J
AQY210
AQY210KS
AQY210KSX
AQY210KSZ
|
193-EEFD
Abstract: 140M-K8P-D40 rockwell E3 plus relay 140M-J8P-D25 193-EEGE 193-EEJF 193-EEHF 140M D18011 140M-J8P-D20
Text: TECHNICAL DATA BULLETIN 100/140M/193 MCS Short-Circuit Current Ratings Short-Circuit Protection Ratings Starting: Short-circuit protective device: Direct-on-line and reversing Bulletin 140M Motor Circuit Protector MCP UL 489 magnetic only Contactor: Bulletins 100-C, 100-D
|
Original
|
PDF
|
100/140M/193
100-C,
100-D
193-E1
100-D210
100-TD100B-EN-P
100-TD100A-EN-P
193-EEFD
140M-K8P-D40
rockwell E3 plus relay
140M-J8P-D25
193-EEGE
193-EEJF
193-EEHF
140M
D18011
140M-J8P-D20
|
relay 12v 100A
Abstract: APP2694 MAX4272 M1 zener
Text: Maxim > App Notes > CIRCUIT PROTECTION HOT-SWAP AND POWER SWITCHING CIRCUITS Keywords: hot-swap, minimizing short-circuit, hot swap controller, current amplitude, short circuit, current spike Sep 11, 2003 APPLICATION NOTE 2694 Minimizing Short-Circuit Current Amplitude and Pulse Width When
|
Original
|
PDF
|
400ns,
10-50microseconds
200ns.
com/an2694
AN2694,
APP2694,
Appnote2694,
relay 12v 100A
APP2694
MAX4272
M1 zener
|
Untitled
Abstract: No abstract text available
Text: Protection Relays & Controls Generator & Single-Function Protection–Overcurrent/Short-Circuit T2500 Series Overcurrent and Short-Circuit Relay Description The combined T2500 3-Phase Overcurrent and Short-Circuit Relay is used for protection of generators and power
|
Original
|
PDF
|
T2500
T2500
EN50081-1,
EN50082-1,
EN50081-2,
EN50082-2
com/t2500
|
DTH circuit diagram
Abstract: DTH block diagram
Text: MOULDED CASE CIRCUIT BREAKERS 2 DS Page DTH.E Page DG Page Adjustable Overload & Fixed Short-circuit Fixed Overload & Fixed Short-circuit Fixed Overload & Fixed Short-circuit release with Normal Breaking Capacity release with High Breaking Capacity Technical Data
|
Original
|
PDF
|
2/58ROTECTION
DTH circuit diagram
DTH block diagram
|
panasonic photomos relay
Abstract: aqy210
Text: GU SOP 1 Form A Short Circuit Protection AQY210KS TESTING Small SOP4-pin type with short circuit protecting (Latch type) GU SOP 1 Form A Short Circuit Protection (AQY210KS) AQY210KS 4.3 .169 4.4 .173 2.1 .083 CAD Data mm inch 1 4 2 3 FEATURES TYPICAL APPLICATIONS
|
Original
|
PDF
|
AQY210KS)
AQY210KS
120mA
aqy210ks:
010611J
panasonic photomos relay
aqy210
|
KD00CK
Abstract: KD/LD MIL-PRF-28750 KD20CK LD20CM KD 130 datasheet KD 500 LD00CM relay 5v 100 ohm relay 6v 100 ohm
Text: Series KD/LD 10A, 60Vdc Optically Isolated, Short-Circuit Protected DC Solid-State Relay Part Number* Relay Description KD00CK 5A Solid-State Relay SSR KD02CK 5A SSR with Switch Status KD20CK 5A SSR with Short-Circuit Protection KD22CK 5A SSR with Short-Circuit Protection and Switch
|
Original
|
PDF
|
60Vdc
KD00CK
KD02CK
KD20CK
KD22CK
LD00CM
LD02CM
LD20CM
LD22CM
KD/LD\072002\Q1
KD00CK
KD/LD
MIL-PRF-28750
KD20CK
LD20CM
KD 130 datasheet
KD 500
LD00CM
relay 5v 100 ohm
relay 6v 100 ohm
|
|
LD00CM
Abstract: LD02CM ld22cm
Text: DC Solid State Relay Series KD/LD SHORT CIRCUIT PROTECTED OPTICALLY ISOLATED, 10A, 60 VDC Part Number Relay Description KD00CK 5 A Solid State Relay SSR KD02CK 5 A SSR with Switch Status KD20CK 5 A SSR with Short Circuit Protection KD22CK 5 A SSR with Short Circuit Protection
|
Original
|
PDF
|
KD00CK
KD02CK
KD20CK
KD22CK
LD00CM
LD02CM
LD20CM
LD22CM
MIL-R-28750
130ApK
LD00CM
LD02CM
ld22cm
|
SP400
Abstract: SP100 SP200 SP315
Text: CIRCUIT PROTECTORS No. 391 / SP Short Circuit Protector Protector, 65V Specifications For Short Circuit Protection of Sensitive Electronic Components and Assemblies Time-Current Characteristic Quick Acting F Packaging 000: Tape/Ammopack (1400 pcs.) Materials
|
Original
|
PDF
|
|
RC5040
Abstract: discrete resistor
Text: www.fairchildsemi.com Application Bulletin Implementing Short Circuit Protection using the RC5040/42 DC-DC Converter for Pentium Pro Implementing Short Circuit Protection Ipk I Intel currently requires all power supply manufacturers to provide continuous protection against short circuit conditions that may damage the CPU. To address this requirement,
|
Original
|
PDF
|
RC5040/42
120OF
AN30000004
RC5040
discrete resistor
|
footprint ceramic capacitor footprint 0402
Abstract: dale fuse resistor 0402 footprint SI6966EDQ .2uF Ceramic Capacitor MOSFET TSSOP-8
Text: Short Circuit Protection Vishay Short Circuit Protection Any accidental short between the output pin and the GND pin of the FunctionPAK could cause permanent damage to the device. Whether that short is the result of component fatigue, accumulation of dust or debris over time, or accidental shorting by
|
Original
|
PDF
|
SI6966EDQ
09-Sep-04
footprint ceramic capacitor footprint 0402
dale fuse resistor
0402 footprint
SI6966EDQ
.2uF Ceramic Capacitor
MOSFET TSSOP-8
|
SP315
Abstract: SP400 SP100 SP200 SP250 IC 404
Text: CIRCUIT PROTECTORS WICKMANN SP / No. 391 Short Circuit Protector Protector, 65V Specifications For Short Circuit Protection of Sensitive Electronic Components and Assemblies Packaging Time-Current Characteristic Materials 000: Tape/Ammopack 1400 pcs. Base/Cap:
|
Original
|
PDF
|
|
APP3328
Abstract: MAX4272 ZENER DIODE 5.1V inrush current circuit AN3328
Text: Maxim > App Notes > AMPLIFIER AND COMPARATOR CIRCUITS HOT-SWAP AND POWER SWITCHING CIRCUITS CIRCUIT PROTECTION Keywords: hot-swap controllers, inrush current, circuit protection, short-circuit current Aug 27, 2004 APPLICATION NOTE 3328 Minimize Short-Circuit Current Pulse in Hot-Swap Controller
|
Original
|
PDF
|
200ns
500ns.
com/an3328
MAX4272:
AN3328,
APP3328,
Appnote3328,
APP3328
MAX4272
ZENER DIODE 5.1V
inrush current circuit
AN3328
|
SP100
Abstract: SP315 SP400 13sp SP200 marking sp x
Text: CIRCUIT PROTECTORS No. 391 / SP Short Circuit Protector Protector, 65 V Specifications Packaging leadfree 000: Tape/Ammopack 1400 pcs. For Short Circuit Protection of Sensitive Electronic Components and Assemblies T ime-Current Characteristic Materials
|
Original
|
PDF
|
days-95
SP100
SP315
SP400
13sp
SP200
marking sp x
|
Untitled
Abstract: No abstract text available
Text: GU 1 Form A Short Circuit Protection AQV112KL VDE Short circuit protection (Non-latch type) only for DC load GU 1 Form A Short Circuit Protection (AQV112KL) AQV112KL 6.4 .252 3.9 .154 8.8 .346 6.4 .252 3.6 .142 8.8 .346 CAD Data CAD Data mm inch 1 6 2 5
|
Original
|
PDF
|
AQV112KL)
AQV112KL
aqv112kl:
011212J
|
Untitled
Abstract: No abstract text available
Text: GU 1 Form A Short Circuit Protection AQV112KL VDE Short circuit protection (Non-latch type) only for DC load 6.4 .252 3.9 .154 8.8 .346 6.4 .252 3.6 .142 8.8 .346 mm inch 1 6 2 5 3 4 RoHS compliant GU 1 Form A Short Circuit Protection (AQV112KL) FEATURES
|
Original
|
PDF
|
AQV112KL)
ASCTB28E
201201-T
|
dc short circuit protection
Abstract: st marking code AMP contact assembly marking code sp SP400 SP315 SP100 SP200 sp-160 13 sp
Text: CIRCUIT PROTECTORS WICKMANN SP / No. 391 Short Circuit Protector Protector, 65V Specifications For Short Circuit Protection of Sensitive Electronic Components and Assemblies Packaging Time-Current Characteristic Materials Base/Cap: Brown Thermoplastic Polyamide PA 6.6, UL 94V0
|
Original
|
PDF
|
days-95%
60Tel:
dc short circuit protection
st marking code
AMP contact assembly
marking code sp
SP400
SP315
SP100
SP200
sp-160