Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    STRAIN GAGE TEST Search Results

    STRAIN GAGE TEST Result Highlights (2)

    Part ECAD Model Manufacturer Description Download Buy
    TMP119AIYBGR
    Texas Instruments ±0.08°C accurate digital temperature sensor in WCSP package with enhanced strain tolerance 6-DSBGA -55 to 150 Visit Texas Instruments
    5962-9322801MXA
    Texas Instruments Test Bus Controllers 68-CFP -55 to 125 Visit Texas Instruments Buy

    STRAIN GAGE TEST Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Contextual Info: RUGGED IN-LINE ROTARY TORQUE SENSORS SENSOR WITH EXCHANGEABLE STRAIN GAGE ELEMENT ߜ One Basic Unit with Different Size, Exchangeable Gage Elements ߜ Especially Suited for Dynamic Measurement ߜ Strain Gage System ߜ Frequency Modulated Data Transmission


    Original
    TQ505 TQ505 DP41-S TQ505H TQ505EH-200 TQ505EH-500 TQ505EH-1K TQ505EH-2K TQ505EH-5K TQ505L, PDF

    shim

    Abstract: welder capacitive discharge LZN-NC-W250G-120 strain Gages chromel alumel MODEL 700 chromel chromel fatigue spot welder strain gage test
    Contextual Info: High-Temperature Weldable Patterns Vishay Micro-Measurements Special Use Strain Gages - Weldable Strain Gages FEATURES • High temperature installations using simple attachment techniques • Ceramic bonded wire gage performance in a weldable gage RoHS COMPLIANT


    Original
    08-Apr-05 shim welder capacitive discharge LZN-NC-W250G-120 strain Gages chromel alumel MODEL 700 chromel chromel fatigue spot welder strain gage test PDF

    7003-8-SG

    Abstract: 7003-8-HL 7000-SM-VC 7000-128-SM 7003-8-A-I
    Contextual Info: System 7000 Micro-Measurements StrainSmart Data Acquisition System FEATURES • Stable, accurate, low-noise signal conditioning • Measurement accuracy ±0.05% • Measurement resolution 0.5 microstrain • Individual input cards for strain gage and strain-gage


    Original
    1000-ohm 27-Apr-11 7003-8-SG 7003-8-HL 7000-SM-VC 7000-128-SM 7003-8-A-I PDF

    Contextual Info: System 8000 Micro-Measurements System 8000 StrainSmart Data Acquisition System FEATURES • Eight software-selectable input channels • Supported inputs include: ❍❍ Strain gage quarter-, half-, and full-bridges ❍❍ Strain-gage-based transducer


    Original
    24-bit 27-Apr-2011 PDF

    vishay m-line rosin solvent

    Abstract: 361A-20R M5S3 570-28R rosin solvent rsk-2 vishay m-flux AR
    Contextual Info: Solders and Accessories Micro-Measurements Solders, Fluxes, Kits, and Soldering Units The quality of the solder joints is a critical element in the performance of any strain gage installation. Because of special requirements associated with strain gage circuitry,


    Original
    27-Apr-2011 vishay m-line rosin solvent 361A-20R M5S3 570-28R rosin solvent rsk-2 vishay m-flux AR PDF

    Contextual Info: High-Temperature Weldable Patterns Micro-Measurements Special Use Strain Gages - Weldable Strain Gages FEATURES • High temperature installations using simple attachment techniques • Ceramic bonded wire gage performance in a weldable gage • Superior performance of bonded gages


    Original
    27-Apr-2011 PDF

    vishay m-line rosin solvent

    Abstract: M-Flux AR kit 361A-20R M-Line Rosin Solvent vishay m-flux AR rosin solvent rsk-2 SILVER SOLDER PASTE 1240-FPA 570-28R M-Flux M-Flux SS
    Contextual Info: Solders and Accessories Vishay Micro-Measurements Solders, Fluxes, Kits, and Soldering Units The quality of the solder joints is a critical element in the performance of any strain gage installation. Because of special requirements associated with strain gage circuitry,


    Original
    08-Apr-05 vishay m-line rosin solvent M-Flux AR kit 361A-20R M-Line Rosin Solvent vishay m-flux AR rosin solvent rsk-2 SILVER SOLDER PASTE 1240-FPA 570-28R M-Flux M-Flux SS PDF

    Contextual Info: Isolated, Wide-Bandwidth Strain Gage Input 5B38 FEATURES Wide-bandwidth Single-Channel Signal Conditioning Interfaces, Amplifies, and Filters signals from full-bridge and half-bridge strain-gage transduces between 300Ω and 10k Isolated Precision Output of -5V to +5V.


    Original
    D05099-0-9/04 PDF

    b1333

    Abstract: PCT-2M M-COAT F vishay PCT-2M strain gage strain gage test GT14 B-133-3 mastic components
    Contextual Info: Instruction Bulletin B-133-3 Vishay Micro-Measurements Strain Gage Installations with M-Bond 300 Adhesive INTRODUCTION Vishay Micro-Measurements M-Bond 300 is a special-purpose, two-component polyester adhesive specially selected for strain gage bonding. It possesses the unusual ability of


    Original
    B-133-3 4-Feb-05 b1333 PCT-2M M-COAT F vishay PCT-2M strain gage strain gage test GT14 B-133-3 mastic components PDF

    Pressure transmitter TBD

    Abstract: ptih-8-4p ptih-8 trans metrics P400 PCIH-10-6P Pressure TransDUCER 4 WIRE lp450 Trans Metrics series 2.00 P450
    Contextual Info: trans metrics , Division of United Electric Controls High Purity Gas Pressure Transducer P400 Series FEATURES: • Reliable bonded foil strain gage technology • Gage, sealed gage, or absolute pressure reference • Integral male or female VCR connection


    Original
    PDF

    Contextual Info: Software for Stress Analysis Testing Micro-Measurements StrainSmart Data Acquisition System StrainSmart is a ready-to-use, Windows®-based software system for acquiring, reducing, presenting, and storing measurement data from strain gages, strain-gage-based


    Original
    27-Apr-11 PDF

    Contextual Info: Model 1300 Micro-Measurements Gage Installation Tester FEATURES • A compact, battery-powered instrument used to verify the electrical quality of a strain gage installation BEFORE it is placed in service • Reads with the push of a button—no warm-up


    Original
    27-Apr-2011 PDF

    H06A-AC1-125-700

    Abstract: TN-501 TN501
    Contextual Info: Magnetic Field Patterns Micro-Measurements Special Use Sensors - Magnetic Field Strain Gages Intense, time-varying electromagnetic fields with steep gradients in field strength can cause troublesome noise in strain gage circuits. In severe magnetic environments, with


    Original
    27-Apr-2011 H06A-AC1-125-700 TN-501 TN501 PDF

    tetra-etch

    Abstract: 430-FST TETRAETCH 1-KL-08-005 142-JWN
    Contextual Info: Wire, Cable and Accessories Micro-Measurements General Information and Selection Different strain gage installation conditions and test specifications often necessitate the use of different types or sizes of leadwires. For accurate, reliable strain measurements, it is important to use an appropriate type of


    Original
    27-Apr-2011 tetra-etch 430-FST TETRAETCH 1-KL-08-005 142-JWN PDF

    CEA-XX-062UL-120

    Abstract: CEA-XX-062UM-120 EA-XX-062RE-120
    Contextual Info: Residual Stress Patterns Micro-Measurements Special Use Sensors - Residual Stress Strain Gages The most widely used practical technique for determining residual stresses is the hole-drilling strain gage method described in ASTM Standard E837. With this method, a


    Original
    TN-503, 062RE CEA-XX-062UM-120 02-Feb-10 CEA-XX-062UL-120 CEA-XX-062UM-120 EA-XX-062RE-120 PDF

    tetra-etch

    Abstract: 430-FST 330-FTE 134-AWN 134-AWQ TETRAETCH 326-DSV 136-awp 326-DTV balco
    Contextual Info: Wire, Cable and Accessories Vishay Micro-Measurements General Information and Selection Different strain gage installation conditions and test specifications often necessitate the use of different types or sizes of leadwires. For accurate, reliable strain measurements, it is important to use an appropriate type of leadwire


    Original
    08-Apr-05 tetra-etch 430-FST 330-FTE 134-AWN 134-AWQ TETRAETCH 326-DSV 136-awp 326-DTV balco PDF

    CEA-XX-062UL-120

    Abstract: CEA-XX-062UM-120 EA-XX-062RE-120 EA-XX-031RE-120 TN-503 E837 SE120 062RE RESIDUAL STRESS PATTERNS 125re
    Contextual Info: Residual Stress Patterns Vishay Micro-Measurements Special Use Sensors - Residual Stress Strain Gages The most widely used practical technique for determining residual stresses is the hole-drilling strain gage method described in ASTM Standard E837. With this method, a


    Original
    TN-503, 08-Apr-05 CEA-XX-062UL-120 CEA-XX-062UM-120 EA-XX-062RE-120 EA-XX-031RE-120 TN-503 E837 SE120 062RE RESIDUAL STRESS PATTERNS 125re PDF

    Contextual Info: System 6000 Micro-Measurements StrainSmart Data Acquisition System FEATURES • From 1 to 1200 input channels • Individual input cards for strain gage and strain-gagebased transducers Model 6010A , thermocouples (Model 6020), sensors with high-level voltage outputs


    Original
    1000-ohm 27-Apr-2011 PDF

    Contextual Info: STRAIN, PROCESS & TEMPERATURE METERS WITH OPTIONAL RELAYS AND ANALOG OUTPUT DP25B Series MADE IN USA Inputs ߜ ߜ ߜ ߜ 245 $ Basic Unit Thermocouple RTD Process dc Voltage and Current Strain Gage Options ߜ Relay Output with Adjustable Deadband ߜ Isolated or Non-Isolated Analog


    Original
    DP25B DP25B -DC10/32 -DC26/56 DP25B-TC-DC10/32-AR, DP25/DP26/PHCN-37/ORCN-37/OPCN-37 PDF

    VISHAY BLH Transducer INDICATOR

    Abstract: BLH transducer
    Contextual Info: 625 BLH Precision Calibrator FEATURES • Accurate to 0.05% of reading • Precisely calibrates full bridge strain gage and transducer instrumentation • Five ranges - 56 calibration points • Test/confirm instrument peak/valley, auto tare, and auto zero circuitry


    Original
    120-ohm 350-ohm 27-Apr-2011 VISHAY BLH Transducer INDICATOR BLH transducer PDF

    AC1310

    Abstract: Strain Gage
    Contextual Info: Analog Devices: IOS Subsystems: Other: 3B16 Narrow Bandwidth, Strain Gage Input Search: Parametric Search | Page 1 of 6 Replacement Parts Search View Cart | My Acco Home > Other Contact ADI | Print this Page | E Other Automatic Test Equipment IOS Subsystems


    Original
    5F868 5F114073 AC1310 Strain Gage PDF

    "Pressure Transducers" dynisco

    Abstract: 1B31AN AC1222 TLC 555 filter design software design Pressure TransDUCER dynisco 31an 79PR
    Contextual Info: ANALOG DEVICES Wide Bandwidth Strain Gage Signal Conditioner Model 1B31 FEATURES Low Cost Complete Signal-Conditioning Solution Small Package: 28-Pin Double DIP Internal Half-Bridge Completion Resistors Remote Sensing High Accuracy Low Drift: ±0.25p.V/°C


    OCR Scan
    28-Pin 140dB 000V/V) 20kHz AD1170 4-to-20mA "Pressure Transducers" dynisco 1B31AN AC1222 TLC 555 filter design software design Pressure TransDUCER dynisco 31an 79PR PDF

    vishay PCT-2M

    Abstract: PLY001 pct-2m installation tape PCT-2M
    Contextual Info: Installation Tools and Accessories Micro-Measurements General Information and Selection There is a strong element of craftsmanship involved in making consistently successful strain gage installations. As for any other field, this craft has its own special tools and


    Original
    27-Apr-2011 vishay PCT-2M PLY001 pct-2m installation tape PCT-2M PDF

    dcdt displacement transducer

    Contextual Info: 2300 System Micro-Measurements Signal Conditioning Amplifier FEATURES • Accepts all strain gage inputs foil and piezoresistive , potentiometers, DCDT’s, etc • Selectable bridge excitation, 0.7 to 15 VDC (11 steps), plus 0.2 to 7 VDC continuously variable


    Original
    1000and 350-ohm 27-Apr-11 dcdt displacement transducer PDF