Contextual Info: Filename: tfs 1188.doc Version 2.0 VI TELEFILTER 26.07.2009 Filter specification TFS 1188 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: Input: Output: 23 °C dBm 50 50 Ω Ω Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1188,8 MHz without any tolerance or |
Original |
||
Contextual Info: Filename: tfs 1204a.doc Version 2.0 VI TELEFILTER 26.07.2009 Filter specification TFS 1204A 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: Input: Output: 23 °C dBm 50 50 Ω Ω Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1204,53 MHz without any tolerance or |
Original |
1204a | |
Contextual Info: Filename: tfs 1227.doc Version 1.2 VI TELEFILTER 6.7.2009 Filter specification TFS 1227 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: Input: Output: 23 °C dBm 50 50 Ω Ω Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1227,6 MHz without any tolerance or |
Original |
||
rx1 1240Contextual Info: Filename: tdx 1176.doc Version 2.0 VI TELEFILTER 26.07.2009 Filter specification TDX 1176 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * source: load: 23 °C dBm 50 Ohm 50 Ohm Characteristics Remark: The maximum attenuation in the pass bands is defined as the insertion loss ae. The nominal frequency fNRX1 is fixed at 1176,45 MHz and the nominal |
Original |
||
Contextual Info: Tfs248e.doc version 6.0 VI TELEFILTER 08.04.2002 Filter specification TFS 248 E 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedances at fc * 23 Input: Output: °C dBm 560 Ω | -5.9pF 500 Ω | -6.3 pF Characteristics |
Original |
Tfs248e 19x6mm | |
MARKING FY
Abstract: 140P3
|
Original |
Tfs140P MARKING FY 140P3 | |
B50A
Abstract: TFS1150A
|
Original |
tfs1150A TFS1150 B50A | |
TFS1880Contextual Info: TFS1880.doc version 1.2 VI TELEFILTER 08.01.2004 Preliminary Specification TFS 1880 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedances for input: for output: 23 C 0 dBm 50 50 Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1880 MHz without any tolerance or |
Original |
TFS1880 | |
TFS1220Contextual Info: TFS1220.doc version 1.4 VI TELEFILTER 21.08.02 Filter specification TFS 1220 1/5 Measurement condition Ambient temperature: 23 °C Input power level: 0 dBm Terminating impedances*: input: 95 Ω // -0.3 pF output: 95 Ω // -0.3 pF Characteristics Remark: |
Original |
TFS1220 | |
Contextual Info: Tfs175d.doc version 1.4 VI TELEFILTER Filter specification 29.05.2002 TFS 175 D 1/5 Measurement condition Ambient temperature: 23 °C Input power level: 0 dBm Terminating impedances at fc *: input: output: 570 Ω // -5,4 pF 500 Ω // -6,4 pF Characteristics |
Original |
Tfs175d | |
603 markingContextual Info: File name: Tfs133.doc version 1.4 VI TELEFILTER 1. Filter Specification 10.10.2001 TFS 133 1/5 Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc * : 2. 23 °C dBm for input: for output: 1656 Ω ÷ê - 7,292 pF. |
Original |
Tfs133 603 marking | |
TFS210GContextual Info: TFS 210G.doc Version 1.4 VI TELEFILTER Filter Specification 03.07.2002 TFS 210G 1/5 Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc * : 23 °C 0 dBm input: output: 860 Ω // -6,4 pF 1,16 kΩ // -6,7 pF Characteristics |
Original |
||
th 2190Contextual Info: Tfs133A.doc Version 1.2 VI TELEFILTER Filter specification 06.03.2003 TFS 133A 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances at fc * : 25 °C 0 dBm. for input: for output: t.b.m. t.b.m. t.b.m. pF. t.b.m. pF. |
Original |
Tfs133A th 2190 | |
836cd
Abstract: 836C
|
Original |
||
|
|||
208HContextual Info: Tfs208h.doc VI TELEFILTER Filter Specification version 1.3 05.02.2003 TFS 208 H 1/5 Measurement Condition Ambient temperature: Input power level: Source impedance: Load impedance: Terminating impedances: * 23 200 50 input: output: C dBm balanced single ended |
Original |
Tfs208h 208H | |
TFS942Contextual Info: TFS942.doc version 1.2 VI TELEFILTER 19.11.2003 Development Specification TFS 942 1/5 Measurement condition 25 ± 2 Ambient temperature: Input power level: Terminating impedance: Input: Output: °C dBm 50 50 Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 942,5 MHz without any tolerance or |
Original |
TFS942 | |
TFS117Contextual Info: Filename: tfs117.doc Version 2.0 VI TELEFILTER 21.03.2003 Filter specification TFS 117 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 °C dBm 288 258 | -22.2 pF | -22.6 pF Characteristics Remark: |
Original |
tfs117 | |
603 marking
Abstract: TFS167D
|
Original |
TFS167D 603 marking | |
Contextual Info: version 1.2 File:TFS188a.doc VI TELEFILTER 14.08.2003 Filter Specification TFS 188 A 1/5 Measurement condition Ambient temperature T A: Input power level: Terminating impedances at fc: * 25 °C ± 2°C 0 dBm input: 1076 output: 831 - 5,8 pF - 6,6 pF Characteristics |
Original |
TFS188a | |
603 markingContextual Info: tfs170.doc version 2.2 06.01.02 VI TELEFILTER Specification TFS 170 - 1/4 |
Original |
tfs170 603 marking | |
156.525 mhz
Abstract: filter 156.525 mhz TFS156A
|
Original |
Tfs156A 156.525 mhz filter 156.525 mhz | |
Contextual Info: file: tfs111b.doc version 1.2 VI TELEFILTER Development specification 28.07.2000 TFS 111B 1/5 Measurement condition Ambient temperature: 23°C Input power level: 10dBm Terminating impedances for input: 3,2 kΩ |- 5,6pF for output: 3,1 kΩ | -6.2pF Characteristics |
Original |
tfs111b 10dBm | |
400d
Abstract: C434
|
Original |
tft025 400d C434 | |
Contextual Info: tfs220E.doc version 1.0 01.07.99 VI TELEFILTER Filter specification TFS 220 E 1/4 |
Original |