Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    THERMOCOUPLE TYPE N Search Results

    THERMOCOUPLE TYPE N Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DE6B3KJ221KN4AE01J
    Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6E3KJ102MA4B
    Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6E3KJ332MB4B
    Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6B3KJ221KB4BE01J
    Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6B3KJ681KN4AE01J
    Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd

    THERMOCOUPLE TYPE N Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    type j thermocouple

    Abstract: type k thermocouple Calex C277C 277c
    Contextual Info: Model 8611 Type J and 8612 Type K Thermocouple to Frequency Converters Features Description n Linearized Frequency n Cold Junction Compensation n 0 to 500°C or 0 to 1000°C Type J Thermocouple n 0 to 1250°C Type K Thermocouple Model 8611. This type J thermocouple to frequency converter


    Original
    PDF

    ANSI MC96.1

    Abstract: ANSI MC96.1-1982 Thermocouple color constantan Thermocouple Type L chromel ANSI MC96.1 TYPE E ANSI MC96.1 TYPE T T-29-520 ANSI MC96.1 TYPE E THERMOCOUPLE
    Contextual Info: INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.53 UL Instrumentation Cable Thermocouple Extension Cables and Thermocouple Wire — Overview Construction Thermocouple Extension Cable Conductor material determined by the thermocouple extension wire type. FEP


    Original
    1-800-BELDEN-1 ANSI MC96.1 ANSI MC96.1-1982 Thermocouple color constantan Thermocouple Type L chromel ANSI MC96.1 TYPE E ANSI MC96.1 TYPE T T-29-520 ANSI MC96.1 TYPE E THERMOCOUPLE PDF

    Calex

    Abstract: type j thermocouple C277C 277c
    Contextual Info: Model 8611 Type J and 8612 Type K Thermocouple to Frequency Converters Features Description n Linearized Frequency n Cold Junction Compensation n 0 to 500°C or 0 to 1000°C Type J Thermocouple n 0 to 1250°C Type K Thermocouple n Isolated Input to Output


    Original
    PDF

    optocoupler thermocouple

    Abstract: calex 8511 Calex 8511
    Contextual Info: Model 8511 Type J and 8512 Type K Thermocouple to Frequency Converters Features Description n Linearized Frequency 10 Hz per degree Centigrade n Cold Junction Compensation n 0 to 500° Type J / K Thermocouple n Isolated Input to Output These thermocouple to frequency converters are designed to


    Original
    PDF

    Contextual Info: EL-WiFi-TC WiFi Thermocouple Data Logging Sensor FEATURES • Temperature data logging sensor with K type thermocouple probe and integrated display • Supports J,K,N,T type thermocouple probes • Easy sensor set-up using the free PC software application downloadable from www.


    Original
    PDF

    Contextual Info: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    115Vac 230Vac PDF

    Contextual Info: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    RS232 PDF

    Contextual Info: Strip Chart Recorders With Thermocouple and Millivolt Inputs Rugged Metal Case for Panel or Bench Operation MADE IN USA ߜ Compact 100 mm 4" Chart Width ߜ Type J Thermocouple Input Switchable Between Thermocouple or Millivolt Input ߜ Set Thermocouple Zero


    Original
    RD-145 RD-146 RD146-JC-MIN, PDF

    Contextual Info: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    115Vac 230Vac PDF

    Contextual Info: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    115Vac 230Vac PDF

    Contextual Info: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    PDF

    Contextual Info: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    115Vac 230Vac PDF

    527-01

    Contextual Info: + – Revised Thermocouple Reference Tables J TYPE Reference Tables N.I.S.T. Monograph 175 Revised to ITS-90 °C -10 -9 -8 -7 -6 -5 -4 Thermocouple Grade Iron vs. Copper-Nickel + – Extension Grade MAXIMUM TEMPERATURE RANGE Thermocouple Grade 32 to 1382°F


    Original
    ITS-90 Z-245 527-01 PDF

    Contextual Info: Low Cost Digital Thermometer Single or Dual Input Models with Type K Thermocouple Input HH10 Series 65 $ Basic Unit Model HH12 Dual Input TJFT72-K-SS-116G-6 thermocouple probe sold separately. The HH10 Series handheld thermometers feature Type K thermocouple input and are available


    Original
    TJFT72-K-SS-116G-6 SC-GG-K-30-36, PDF

    Contextual Info: Low Noise Thermocouple Probes with High Temperature Standard Size Connectors SUPER OMEGACLAD XL THERMOCOUPLE WIRE MAXIMUM PERFORMANCE SHEATING & TM ELIMINATES HIGH TEMPERATURE DRIFT Available in Type K or Type N, Consult Sales for Specifications and Pricing.


    Original
    HGTQSS-116( HGTQSS-18( HGTQSS-316( HGTQSS-14( GS-GST-10, 75/pkg 321SSâ HGKQ321SS-316G-12 HGKQSS-316G-12, 304SS PDF

    Contextual Info: Weller Type K Thermocouple Assembly with LTB Tip Product Details Catalog No. UPC Code Fits Tool s Description Packaging Tech. Spec. Stock Item K181 037103166746 WA2000 Type K Thermocouple for LTB Industrial Box/Carton Solder_Safety_Warnings.pdf Normal Stock Item


    Original
    WA2000 PDF

    Contextual Info: Isolated, Linearized, Thermocouple Input 3B47 FEATURES Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal cold junction compensation.


    Original
    D05162-0-9/04 PDF

    NEDA 1604 6F22 006P

    Abstract: FLUKE 36 schematic diagram NEDA 1604 6F22 SAMA-CP45 80PK-2 6F22 9V calibration procedure for thermocouple Fluke Multimeter repair 741512 80PK-1
    Contextual Info: IF L U K E I — — — — Instruction Sheet 80TK Thermocouple Module INTRODUCTION Range Accuracy % of reading + degrees The Fluke 80TK is a thermocouple converter for use with any Ktype thermocouple and a digital multimeter (DMM). The 80TK accepts the output of any K-type thermocouple and converts it to


    OCR Scan
    PDF

    SUPER MCJ

    Contextual Info: Thermocouple Input Super MCJ Analog Output, 1 mV per degree SMP or OST Connector SMCJ-J, SMCJ-K, SMCJ-T INSTRUCTION SHEET M-2813 Thermocouple-to-Analog Connector GENERAL DESCRIPTION This is a Thermocouple to Analog Connector. It converts a thermocouple input signal (Type J, K, or T) to a linear, compensated, amplified analog


    Original
    M-2813 SUPER MCJ PDF

    Contextual Info: Weller Type K Thermocouple Assembly With LTB Tip Product Details Catalog No. UPC Code Fits Tool s K1111 037103223821 WA2000 Type K Description Thermocouple for LTB Packaging Industrial Box/Carton Stock Item Normal Stock Item Package Details (Dimensions) Product Features:


    Original
    K1111 WA2000 WA2000 PDF

    circuito sensor capacitivo

    Abstract: rs232 schema rs 232 RS-232-Kabel psion rs232 IRZE ir 9027 termocoppia tipo k sonde thermocouple type S
    Contextual Info: VARIOUS OPERATING MODES EXEMPLES DE MODES DE FONCTIONNEMENT VERSCHIEDENE BETRIEBSARTEN ESEMPI DI MODALITA' DI FUNZIONAMENTO “K" type thermocouple Thermocouple de type "K" BLUE BLAU BLEU BLU BROWN BRAUN MARRON MARRONE + - „K"-Thermoelement Termocoppia tipo "K"


    Original
    SL-750/S circuito sensor capacitivo rs232 schema rs 232 RS-232-Kabel psion rs232 IRZE ir 9027 termocoppia tipo k sonde thermocouple type S PDF

    PM 8058

    Abstract: AD594A TRANSDUCER PX 605 PM 8058 ic AD595AQ AD696
    Contextual Info: ANALOG DEVICES Monolithic Thermocouple Amplifiers with ColdJunction Compensation AD594*/AD595* FEATURES Pretrimmed for Type J AD594 or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10mV/°C Built-in Ice Point Compensation


    OCR Scan
    AD594) AD595) AD594 /AD595* PM 8058 AD594A TRANSDUCER PX 605 PM 8058 ic AD595AQ AD696 PDF

    AD595

    Abstract: AD595 thermocouple NICR-NI thermocouple ice point compensation feedback thermocouple AD594 AD594A AD594AD AD594C AD595A AD595C
    Contextual Info: a Monolithic Thermocouple Amplifiers with Cold Junction Compensation AD594/AD595 FEATURES Pretrimmed for Type J AD594 or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10 mV/؇C Built-In Ice Point Compensation


    Original
    AD594/AD595 AD594) AD595) O-116 AD595 AD595 thermocouple NICR-NI thermocouple ice point compensation feedback thermocouple AD594 AD594A AD594AD AD594C AD595A AD595C PDF

    NICR-NI thermocouple

    Abstract: nicr-ni temperature Thermocouple Type K material 6790 pf 27 AD595A 680 ohms resistor 5 watt datasheet AD595 thermocouple cold junction compensation of t type thermocouple AD595 C731e
    Contextual Info: a Monolithic Thermocouple Amplifiers with Cold Junction Compensation AD594*/AD595* FEATURES Pretrimmed for Type J AD594} or Type K (AD595 Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10 mV/؇C Built-In Ice Point Compensation


    Original
    AD594 /AD595* AD594} AD595) AD594/AD595 O-116 NICR-NI thermocouple nicr-ni temperature Thermocouple Type K material 6790 pf 27 AD595A 680 ohms resistor 5 watt datasheet AD595 thermocouple cold junction compensation of t type thermocouple AD595 C731e PDF