Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    THERMOCOUPLES Search Results

    THERMOCOUPLES Result Highlights (1)

    Part ECAD Model Manufacturer Description Download Buy
    TIPD109
    Texas Instruments Simple Thermocouple Measurement Solution Reference Design, <1°C Accurate Visit Texas Instruments
    SF Impression Pixel

    THERMOCOUPLES Price and Stock

    Phoenix Contact

    Phoenix Contact 2688417

    I/O Modules AXL UTH 8
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 2688417 Each 1
    • 1 $693.55
    • 10 $653.55
    • 100 $653.55
    • 1000 $653.55
    • 10000 $653.55
    Buy Now

    Phoenix Contact 2905632

    Terminal Block Interface Modules MINI MCR-2-T-REL
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 2905632 Each 1
    • 1 $177.54
    • 10 $177.54
    • 100 $177.54
    • 1000 $177.54
    • 10000 $177.54
    Buy Now

    Phoenix Contact 2905249

    Terminal Block Interface Modules MINI MCR-2-TC-UI-PT
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 2905249 Each 1
    • 1 $222.12
    • 10 $222.12
    • 100 $222.12
    • 1000 $222.12
    • 10000 $222.12
    Buy Now

    Phoenix Contact 2865654

    Terminal Block Interface Modules MACX MCR-EX-T-UI-UP
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 2865654 Each 1
    • 1 $583.18
    • 10 $583.18
    • 100 $583.18
    • 1000 $583.18
    • 10000 $583.18
    Buy Now

    Phoenix Contact 2811378

    Terminal Block Interface Modules MACX MCR-T-UIREL-UP
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 2811378 Each 1
    • 1 $505.63
    • 10 $495.72
    • 100 $495.72
    • 1000 $495.72
    • 10000 $495.72
    Buy Now

    THERMOCOUPLES Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    ANSI MC96.1

    Abstract: MC96-1-82 ANSI MC96.1 TYPE T DSCA47J-01 EN50081-1 EN50082-1 ITS-90 monograph monograph 175
    Contextual Info: DSCA47 Linearized Thermocouple Input Signal Conditioners FEATURES DESCRIPTION ● INTERFACES TO TYPES J, K, T, E, R, S, B, AND N THERMOCOUPLES Each DSCA47 thermocouple input module provides a single channel of thermocouple input which is filtered, isolated, amplified, linearized, and converted


    Original
    DSCA47 DSCA47 DSCA47J-01 DSCA47J-01C DSCA47J-01E ANSI MC96.1 MC96-1-82 ANSI MC96.1 TYPE T DSCA47J-01 EN50081-1 EN50082-1 ITS-90 monograph monograph 175 PDF

    NE-2H

    Abstract: PWS740 ISO120 ISO120BG ISO120G ISO120SG ISO121 ISO121BG ISO121G PT100 table
    Contextual Info: ISO120 ISO121 Precision Low Cost ISOLATION AMPLIFIER FEATURES APPLICATIONS ● ● ● ● ● ● INDUSTRIAL PROCESS CONTROL: Transducer Isolator for Thermocouples, RTDs, Pressure Bridges, and Flow Meters, 4mA to 20mA Loop Isolation ● GROUND LOOP ELIMINATION


    Original
    ISO120 ISO121 ISO120: 1500Vrms ISO121: 3500Vrms 115dB 24-PIN ISO120) NE-2H PWS740 ISO120 ISO120BG ISO120G ISO120SG ISO121 ISO121BG ISO121G PT100 table PDF

    MPY100

    Abstract: 1N4148 PWS740 free transistor data base book A.Z
    Contextual Info: ISO122 Precision Lowest Cost ISOLATION AMPLIFIER FEATURES APPLICATIONS ● 100% TESTED FOR HIGH-VOLTAGE BREAKDOWN ● INDUSTRIAL PROCESS CONTROL: Transducer Isolator, Isolator for Thermocouples, RTDs, Pressure Bridges, and Flow Meters, 4mA to 20mA Loop Isolation


    Original
    ISO122 1500Vrms 140dB 16-PIN 28-LEAD ISO122 MPY100 1N4148 PWS740 free transistor data base book A.Z PDF

    x0605

    Abstract: MC96-1-82 thermistor ntc 30k monograph 175 ANSI MC96.1 TYPE T AN505 AN701 EN50081-1 EN50082-1 Thermocouple Type K linearization
    Contextual Info: SCM7B47 Isolated Linearized Thermocouple Input Modules FEATURES DESCRIPTION ● INTERFACES TO TYPES J, K, T, E, R, S, B AND N THERMOCOUPLES SCM7B47 modules accept a single channel of input from Type J, K, T, E, R, S, B, or N thermocouples. The signal is filtered, isolated, amplified, linearized, and converted


    Original
    SCM7B47 SCM7B47 AN505. 1500Vr x0605 MC96-1-82 thermistor ntc 30k monograph 175 ANSI MC96.1 TYPE T AN505 AN701 EN50081-1 EN50082-1 Thermocouple Type K linearization PDF

    Resistance characteristic Pt1000

    Abstract: PT100 SENSOR rtd sensor pt100 temperature transmitter pt100 4-20ma atex Resistance characteristic Ni1000 PT1000 PT500 PT1000 thermocouple PT500 IEC 751 PT500 temperature sensor
    Contextual Info: Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer MCR-FL-HT-T-I-Ex 1. Brief Description – For resistance thermometers, thermocouples, and resistance and voltage sensors – For installation in Form B connection head POWER FL I


    Original
    PDF

    k thermocouple amplification circuit diagram

    Abstract: SCXI-1303 electromagnetic parking sensor SCXI-1100 thermocouple multiplexer constantan seebeck Table
    Contextual Info: Application Note 056 How to Use Thermocouples with an SCXI-1100 Module This application note describes how to set up and use the SCXI-1100 with thermocouples. It also describes example programs that use the SCXI-1100 to make thermocouple measurements. These example programs are included on the SCXI Application Examples disk included in the


    Original
    SCXI-1100 k thermocouple amplification circuit diagram SCXI-1303 electromagnetic parking sensor thermocouple multiplexer constantan seebeck Table PDF

    RTD PT100

    Abstract: PWS740 ISO120 ISO120BG ISO120G ISO120SG ISO121 ISO121BG ISO121G
    Contextual Info: ISO120 ISO121 Precision Low Cost ISOLATION AMPLIFIER FEATURES APPLICATIONS ● ● ● ● ● ● INDUSTRIAL PROCESS CONTROL: Transducer Isolator for Thermocouples, RTDs, Pressure Bridges, and Flow Meters, 4mA to 20mA Loop Isolation ● GROUND LOOP ELIMINATION


    Original
    ISO120 ISO121 ISO120: 1500Vrms ISO121: 3500Vrms 115dB 24-PIN ISO120) RTD PT100 PWS740 ISO120 ISO120BG ISO120G ISO120SG ISO121 ISO121BG ISO121G PDF

    SCXI-1120D

    Abstract: SCXI-1120 TBX-1329 SCXI-1327 776572-20
    Contextual Info: SCXI-1120, SCXI-1120D 8-Channel Isolation Amplifiers SCXI-1120, SCXI-1120D Isolated signal conditioning for Thermocouples Millivolt and volt inputs 4-20 mA or 0-20 mA inputs Isolates, amplifies, and multiplexes 8 channels 250 Vrms working isolation per channel


    Original
    SCXI-1120, SCXI-1120D SCXI-1120) SCXI-1120D) SCXI-1327 220/gain) SCXI-1120D SCXI-1120 TBX-1329 SCXI-1327 776572-20 PDF

    THERMOCOUPLE AMPLIFIER

    Abstract: SCXI-1102 SCXI-1310
    Contextual Info: SCXI 32-Channel Thermocouple Amplifier SCXI-1102 SCXI-1102 Features 32 differential channels Low-noise signal conditioning for: Thermocouples Low-bandwidth millivolt and volt signals 4-20 mA or 0-20 mA inputs Lowpass noise filters on every channel Programmable instrumentation amplifier


    Original
    32-Channel SCXI-1102 SCXI-1102 96-pin SCXI-1200, PCI-1200, DAQCard-1200, THERMOCOUPLE AMPLIFIER SCXI-1310 PDF

    INA102

    Abstract: INA102AG INA102AU ECG Amplifier
    Contextual Info: INA102 Low Power INSTRUMENTATION AMPLIFIER FEATURES APPLICATIONS ● LOW QUIESCENT CURRENT: 750µA max ● AMPLIFICATION OF SIGNALS FROM SOURCES SUCH AS: Strain Gages Weigh Scale Applications Thermocouples Bridge Transducers ● REMOTE TRANSDUCER AMPLIFIER


    Original
    INA102 INA102 INA102AG INA102AU ECG Amplifier PDF

    circuit diagram for split air conditioner

    Abstract: AD597 AD597A circuit op07 for thermocouple type k control thermocouple AD597H circuit diagram of split air conditioner OVEN* temperature sensor AD594 AD596
    Contextual Info: a FEATURES Low Cost Operates with Type J AD596 or Type K (AD597) Thermocouples Built-In Ice Point Compensation Temperature Proportional Operation – 10 mV/؇C Temperature Setpoint Operation – ON/OFF Programmable Switching Hysteresis High Impedance Differential Input


    Original
    AD596) AD597) AD596 /AD597* O-100 AD596/AD597 C831b circuit diagram for split air conditioner AD597 AD597A circuit op07 for thermocouple type k control thermocouple AD597H circuit diagram of split air conditioner OVEN* temperature sensor AD594 PDF

    Contextual Info: Or, Call Customer Service at 1-800-548-6132 USA Only is s a r m 1S 0 2 1 2 P q p IS0212P • p APPLICATIONS • • • • • INDUSTRIAL PROCESS CONTROL: Transducer Channel Isolator for Thermocouples, RTDs, Pressure Bridges, Flow Meters • 4mA TO 20mA LOOP ISOLATION


    OCR Scan
    IS0212P 12-BIT IS0212P 100kQ 1-M0-548-6132 PDF

    Contextual Info: B U R R - B R O W N <i [ ] IS0212P r Low Cost, Two-Port Isolated, 1500Vrms ISOLATION AMPLIFIER FEATURES APPLICATIONS • 12-BIT ACCURACY • INDUSTRIAL PROCESS CONTROL: Transducer Channel Isolator for Thermocouples, RTDs, Pressure Bridges, Flow Meters • 2.5mA typ QUIESCENT CURRENT


    OCR Scan
    IS0212P 1500Vrms 12-BIT 4-20mA PDF

    PC-SSO-32

    Abstract: LTKA0x LT1091A thermocouple copper ltc 1025 LT1025 LT398 serial "compass Sensor" application note LT1034 chopper transformer
    Contextual Info: Application Note 28 February 1988 Thermocouple Measurement Jim Williams Introduction Thermocouples in Perspective In 1822, Thomas Seebeck, an Estonian physician, accidentally joined semicircular pieces of bismuth and copper Figure 1 while studying thermal effects on galvanic arrangements. A nearby compass indicated a magnetic disturbance. Seebeck experimented repeatedly with different


    Original
    an28f AN28-19 AN28-20 PC-SSO-32 LTKA0x LT1091A thermocouple copper ltc 1025 LT1025 LT398 serial "compass Sensor" application note LT1034 chopper transformer PDF

    ERF 2030

    Abstract: LTKA LT1025AC PL II thermocouple LT1025 T1025 LT1025ACN8 LT1025AM LT1025AMJ8 LT1025C
    Contextual Info: _ LT1025 r r u n m te c h n o lo g y Micropower Thermocouple Cold Junction Compensator F€ATUA€S D C S C R IP T IO n • ■ ■ ■ 80iiA Supply Current 4V to 36V Operation 0.5°C Initial Accuracy A Version Compatible with Standard Thermocouples


    OCR Scan
    80/iA 10mV/Â LT1025 LT1025 588-r ERF 2030 LTKA LT1025AC PL II thermocouple T1025 LT1025ACN8 LT1025AM LT1025AMJ8 LT1025C PDF

    Signal Conditioners

    Abstract: AD595 ice point compensation AD594 AD595 thermocouple AD596 temperature transducers
    Contextual Info: Signal Conditioners Temperature Transducer Signal Conditioners -IN -A LM +ALM V+ COM » VO FB AD594/AD595 Pretrimmed for Type J AD594 or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10mV/°C Built-In Ice Point Compensation


    OCR Scan
    AD594/AD595 AD594) AD595) 10mV/Â AD596 Signal Conditioners AD595 ice point compensation AD594 AD595 thermocouple AD596 temperature transducers PDF

    AC1501

    Abstract: AD2036 ad2009 "BCD Switch" AD2016 digital clock diagram built by bcd segment thermocouple multiplexer L type thermocouple conversion table AD2022 COUNTER LED bcd
    Contextual Info: ► ANALOG DEVICES 6 Channel Scanning Digital Thermometer FEA TUR ES Automatic Scan of 6 Thermocouples TC's Manual Selection of Individual TC's External Channel Selection by BCD Code J, K, or T Thermocouple °C or °F: Readout Self Contained Linearization


    OCR Scan
    AD2036 1151-MAX AC1501 ad2009 "BCD Switch" AD2016 digital clock diagram built by bcd segment thermocouple multiplexer L type thermocouple conversion table AD2022 COUNTER LED bcd PDF

    SCXI-1121

    Abstract: SCXI-1120
    Contextual Info: SCXI-1121 SCXI 4-Channel Isolation Amplifier with Excitation SCXI-1121 Isolated signal conditioning for Strain gauges RTDs Thermistors Millivolt and volt inputs 4-20 mA or 0-20 mA with resistor kit Thermocouples 4 isolated current or voltage excitation channels


    Original
    SCXI-1121 SCXI-1327 SCXI-1321 SCXI-1327 SCXI-1305 AT-MIO-16E-2 AT-MIO-16X SCXI-1121 SCXI-1120 PDF

    Thermocouple Type K

    Abstract: thermocouple diesel engine accuracy of K type thermocouple J type thermocouple circuit with thermocouple application k type thermocouple T type thermocouple Thermocouple Type K temperature data sheet control thermocouple
    Contextual Info: FP0 Thermocouple Modules FP0-TC4 FP0-TC8 The FP0-TC4 and FP0-TC8 thermocouple units are suitable for user friendly temperature acquisition using standard thermocouples with a high precision. - TC inputs: 4ch and 8ch type The temperature of up to 24 channels can be controlled


    Original
    8024-pe Thermocouple Type K thermocouple diesel engine accuracy of K type thermocouple J type thermocouple circuit with thermocouple application k type thermocouple T type thermocouple Thermocouple Type K temperature data sheet control thermocouple PDF

    LM 1605 CK

    Abstract: AD596A AD597H transistor D596 LT 6243
    Contextual Info: ANALOG DEVICES FEATURES Low Cost Operates w ith Type J AD596 or Type K (AD597) Thermocouples Built-In Ice Point Compensation Tem perature Proportional Operation - 1 0 m V /°C Tem perature Setpoint Operation - O N /O FF Programmable Switching Hysteresis


    OCR Scan
    AD596) AD597) AD596/AD597 LM 1605 CK AD596A AD597H transistor D596 LT 6243 PDF

    2SC 8050

    Abstract: 403M AC1226 Amplifier type t thermocouple 1B51 circuit with thermocouple application cold junction compensation of t type thermocouple kovar thermocouple
    Contextual Info: Micropower Thermocouple Cold Junction Compensator A N A LO G ► D E V IC E S ri-s - X .r ' : -, -?•*# - f r s K ^ s g l FEATURES 80|jlA Supply Current 4V to 36V Operation 0.5°C Typical Initial Accuracy Compatible with Standard Thermocouples E. J, K, R, S. T


    OCR Scan
    10mV/cC AC1226 2SC 8050 403M Amplifier type t thermocouple 1B51 circuit with thermocouple application cold junction compensation of t type thermocouple kovar thermocouple PDF

    MAX31855J

    Abstract: MAX31855 max31855k 200nC Thermocouple Type K MAX31855T
    Contextual Info: 19-5793; Rev 0; 3/11 MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter General Description The MAX31855 performs cold-junction compensation and digitizes the signal from a K, J, N, T, or E type thermocouple. Contact the factory for S and R type thermocouples. The data is output in a signed 14-bit, SPI compatible, read-only format. This converter resolves


    Original
    MAX31855 14-bit, 1800NC -270NC, -200NC 700NC MAX31855J max31855k 200nC Thermocouple Type K MAX31855T PDF

    PWS740

    Contextual Info: ISO120 ISO121 Precision Low Cost ISOLATION AMPLIFIER FEATURES APPLICATIONS ● ● ● ● ● ● INDUSTRIAL PROCESS CONTROL: Transducer Isolator for Thermocouples, RTDs, Pressure Bridges, and Flow Meters, 4mA to 20mA Loop Isolation ● GROUND LOOP ELIMINATION


    Original
    ISO120 ISO121 ISO120: 1500Vrms ISO121: 3500Vrms 115dB 24-PIN ISO120) PWS740 PDF

    Contextual Info: Extract from the online catalog IB IL TEMPCON UTH Order No.: 2819312 Inline temperature regulators, without accessories, 8 inputs for thermocouples, 8 outputs, 24 V DC, 2-wire connection method


    Original
    PDF