Untitled
Abstract: No abstract text available
Text: VSWR, Return Loss and Transmission Loss vs. Transmitted Power VSWR Return Loss dB Trans. Loss (dB) Volt. Refl Coeff Power Trans (%) Power Refl (%) VSWR Return Loss (dB) Trans. Loss (dB) Volt. Refl Coeff Power Trans (%) Power Refl (%) 1.00 1.01 1.02 1.03
|
Original
|
PDF
|
9/03A
|
Untitled
Abstract: No abstract text available
Text: Attenuators Definition of Parameters Attenuation - The technical term is most often used in connection with loss or insertion loss in a transmission line. Insertion loss is a combination of two types of losses; impedance mismatch loss reflective and attenuation loss
|
Original
|
PDF
|
|
C0814
Abstract: No abstract text available
Text: - PROPRIETARY INFORMATION - 6-Way Power divider SURFACE MOUNT MODEL: DFS-905 WIDE BANDWIDTH 1 - 500 MHz -7 Transmission Loss/Amp. Unbalance dB FEATURES: ► Wide Bandwidth ► Low Loss ► Closely Controlled Phase/Amplitude Unbalance -7.5 -8 -8.5 -9 -9.5
|
Original
|
PDF
|
DFS-905
In-12
In-15
In-16
C0814
|
CM310
Abstract: mtbf antenna GSM1800 GSM900 LOW BAND antenna mtbf Filtronic
Text: CM310V1 Indoor Cross Band Combiner - Indoor FEATURES • Very low loss • Very high return loss • Low IMD • High power handling • RoHS compliant BENEFITS • Allows two systems to be combined onto a single transmission line for simplified antenna feed.
|
Original
|
PDF
|
CM310V1
CM310
GSM900
GSM1800
mtbf antenna
LOW BAND antenna mtbf
Filtronic
|
Untitled
Abstract: No abstract text available
Text: SERIES 7/16 COAXIAL CONNECTORS Description SUHNER 7/16 connectors are mechanically very rugged coaxial connectors with screw lock. They have a characteristic impedance of 50 Ω and are applicable with excellent electrical properties up to 7.5 GHz. Transmission of medium to high power in transmitting stations and low loss transmission of received
|
Original
|
PDF
|
MIL-STD-202,
IEC-68-2-11
QQ-B-626
|
Untitled
Abstract: No abstract text available
Text: 79 signal transmission in high frequency/high density applications Impedance Three Examples An inherent characteristic for transmission lines is impedance, which is measured in ohms. Impedance is the ratio of voltage to current in a traveling wave. For a "loss-less" cable, it can be
|
Original
|
PDF
|
Log10
|
Untitled
Abstract: No abstract text available
Text: SERIES 7/16 COAXIAL CONNECTORS DESCRIPTION HUBER+SUHNER 7/16 connectors are mechanically very rugged coaxial connectors with screw lock. They have a characteristic impedance of 50 Ω and are applicable with excellent electrical properties up to 7.5 GHz. Transmission of medium to high power in transmitting stations and low loss transmission of received
|
Original
|
PDF
|
MIL-STD-202,
QQ-B-626
|
diplexers
Abstract: WR284 Hybrid loss wr90
Text: ATLANTIC DIVISION Diplexers High-Power Waveguide Diplexers Features • Low Passband Loss • High Power Carriers Combined With Minimal • Multiple Loss • High Signal Isolation Diplexer - the simultaneous transmission or reception of two RF signals. Multiplex - a system of transmitting several signals on the same circuit.
|
Original
|
PDF
|
|
ESD25
Abstract: PJLCDA05 PJLCDA12 PJLCDA15 8-20us
Text: PJLCDA05 SERIES ULTRA LOW CAPACITANCE QUAD TVS ARRAY FOR HIGH SPEED TRANSMISSION DATA LINES This Transient Voltage Suppressor Array is intended to Protect Sensitive Equipment against Electrostatic Discharge and Transient Events as well to offer a miminum insertion loss in high speed data communication transmission line
|
Original
|
PDF
|
PJLCDA05
IEC61000-4-2
PJLCDA05
PJLCDA12
PJLCDA15
PJLCDA24
ESD25
PJLCDA12
PJLCDA15
8-20us
|
DFS-905
Abstract: No abstract text available
Text: 6-Way Power divider SURFACE MOUNT MODEL: DFS-905 WIDE BANDWIDTH 1 - 500 MHz -7 Transmission Loss/Amp. Unbalance dB FEATURES: ► Wide Bandwidth ► Low Loss ► Closely Controlled Phase/Amplitude Unbalance -7.5 -8 -8.5 -9 -9.5 -10 1 101 201 301 401 501 Frequency (MHz)
|
Original
|
PDF
|
DFS-905
In-12
In-15
In-16
DFS-905
|
SMF-28TM
Abstract: polarization dependent isolator
Text: Polarization Independent Isolator M-II Features • Ultra high isolation • Minimum polarization dependent loss PDL • Polarization mode dispersion (PMD) free • Optical path epoxy free • Low insertion loss • Environmentally stable Applications • Optical amplification & transmission
|
Original
|
PDF
|
LUMNDS040-0302
SMF-28TM
polarization dependent isolator
|
PLC-WP100-R
Abstract: bv32 G.729.1 ZSP400 BroadVoice16 introduction to cvsd CVSD bluetooth pesq pcm thyssen BV16
Text: White Paper Improving the Quality of Communications with Packet Loss Concealment In digital transmission of speech and audio signals, lost or corrupted frames and packets can severely degrade audio quality at the receiver. A special technique known as Packet Loss
|
Original
|
PDF
|
AH-06-38r2.
PLC-WP100-R
PLC-WP100-R
bv32
G.729.1
ZSP400
BroadVoice16
introduction to cvsd
CVSD bluetooth
pesq pcm
thyssen
BV16
|
wdm Mux
Abstract: No abstract text available
Text: Thin Film Coarse WDM M-CT Device Image Features • Environmentally stable • Easy installation • Custom defined specifications • Low return loss • Low insertion loss • High Channel Isolation Applications • CWDM transmission system • Local area network
|
Original
|
PDF
|
LUMNDS036-0402
wdm Mux
|
S3D1723
Abstract: No abstract text available
Text: 3-Way Power divider SYNSTRIP MODEL: S3D1723 optimized BANDWIDTH 1700 - 2300 MHz FEATURES: ► SYNSTRIPTM Technology ► Small Size, Surface Mount ► Optimum Performance Transmission Loss/Ampl Unnbalance dB 5.5 APPLICATIONS: ► Signal Splitting & Low Power Combining
|
Original
|
PDF
|
S3D1723
CDMA-2000,
S3D1723
|
|
Untitled
Abstract: No abstract text available
Text: 3-WAY POWER DIVIDER CONNECTORIZED MODEL: DCK-3-7S WIDE BANDWIDTH 20 - 1200 MHz FEATURES: ► Excellent Performance ► Wide Bandwidth ► Moderate Power Transmission Loss/Amp. Unbalance dB 4.5 APPLICATIONS: ► Signal Splitting & Low Power Combining 5 5.5
|
Original
|
PDF
|
113LF
|
Untitled
Abstract: No abstract text available
Text: B&B ELECTRONICS FOSTDRP0912 – pg. 1/2 Double Your Fiber Distance with A Duplex Fiber Repeater Model FOSTDRP Description Model FOSTDRP is used to overcome fiber loss, connector loss, and splice loss in a fiber optic link. Used in the middle of a fiber optic link, model FOSTDRP effectively doubles the transmission distance. Model FOSTDRP acts as an active splice to
|
Original
|
PDF
|
FOSTDRP0912
89/336/EEC
|
M21352
Abstract: M21353 M21351 mindspeed equalizer 424m SMPTE SDI 425 express card DVB
Text: > Product Overview Mindspeed’s family of 4.25 Gbps backplane signal conditioners feature small form factor, low power devices that enable data transmission over long backplanes at speeds up to 4.25 Gbps. Mindspeed’s Amplif-Eye signal conditioning technology enables transmission of 4.25 Gbps data over significant distances while traversing two backplane connectors. These products are specifically designed to operate in environments that suffer from both loss and reflection.
|
Original
|
PDF
|
M21351-2-3-BRF-001-D
M21352
M21353
M21351
mindspeed equalizer
424m
SMPTE SDI 425
express card DVB
|
Untitled
Abstract: No abstract text available
Text: Coaxial Transmission Line Technical Data Figure 1 - Variation of Attenuation with Ambient Temperature Figure 2 - Effect of Load VSW R on Transmission Loss V S W R at T erm in ation Attenuation Effect of Connector on Transmission Line Loss The attenuation versus frequency characteristics of
|
OCR Scan
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Attenuators Definition of Parameters Attenuation - The technical term is most often used in connection with loss or insertion loss in a transmission line. Insertion loss is a combination of two types of losses; imped ance mismatch loss reflective and attenuation loss (dissi
|
OCR Scan
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: micRownvE componEívrs □ NOTES 3-dB Coaxial Hybrids, 3-dB 90°Card couplers> Degree of coupling: Represented by Nominal value (3 dB -^-Insertion loss (dB) Insertion loss: Power loss during transmission of a signal in a product (dB) Insertion loss (dB) = 10 log (P2 output power - f P3 output power) /P I input power)
|
OCR Scan
|
PDF
|
|
nomograph
Abstract: No abstract text available
Text: SWR NOMOGRAPH #1 SWR 1 .0 VOLTAGE REFL. COEFF. POWER RETURN REFLECTED LOSS % dB o- - POWER TRANSM ITTED % TRANSMISSION LOSS dB 100 - 1.3 1.5 - .2 - 13 . 0 1. 7 1 .9 2. 0 - . 3- 10- .3 5 - 10.0 • 9 .5 9 .0 - . 90- 8 .5 - 8. 0 - .4 0 - . 5- . 6 - . 7 - . 8
|
OCR Scan
|
PDF
|
|
nomograph
Abstract: SWR NOMOGRAPH
Text: SWR NOMOGRAPH #2 SWR 1. 0 - 1.1 - VOLTAGE REFL. COEFF. POWER RETURN REFLECTED LOSS % dB o- 30: 05- . 25 24 23 1. 1 5 - POWER TRANS M ITTED % 1 00 - TRANSMISSION LOSS dB O — i— - 22 1. 2 21 - 20 10- . - 99.05 19- 1.3 18 - 98- 17 . 15- .1 0 -16 1. 4
|
OCR Scan
|
PDF
|
90-EFLECTED
nomograph
SWR NOMOGRAPH
|
Untitled
Abstract: No abstract text available
Text: Sw itches A coaxial switch is used to alter the path of a coaxial transmission line by either opening or closing it, or changing its direction. The coaxial switch is used in the microwave field due to the inherent properties of the structure, which has high isolation and low loss energy transmission, over extremely wide bandwidths. These characteristics plus
|
OCR Scan
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Switches A coaxial switch is used to alter the path of a coaxial transmission line by either opening or closing it, or changing its direction. The coaxial switch is used in the microwave field due to the inherent properties of the structure, which has high isolation and low loss energy transmission, over extremely wide bandwidths. These characteristics plus
|
OCR Scan
|
PDF
|
|