The recommended operating voltage range for the 74HC2G08DP,125 is 2.0 V to 7.0 V, with a typical voltage of 5.0 V.
It is recommended to power up the VCC pin before the input signals, and power down the VCC pin after the input signals. This ensures that the device is properly initialized and avoids any potential latch-up or damage.
The maximum frequency of operation for the 74HC2G08DP,125 is 100 MHz, but this can vary depending on the specific application and operating conditions.
It is recommended to use a 0.1 μF to 1 μF decoupling capacitor between the VCC pin and the GND pin, as close to the device as possible, to filter out any noise and ensure stable operation.
The maximum output current that the 74HC2G08DP,125 can sink or source is 25 mA per output pin, with a total current limit of 100 mA for all output pins combined.