A 2-layer or 4-layer PCB with a solid ground plane and thermal vias is recommended. Ensure a minimum of 1 mm clearance around the device for heat dissipation.
Use a decoupling capacitor (e.g., 100 nF) close to the device, and ensure the supply voltage is within the recommended range (4.5 V to 5.5 V).
The maximum allowed power dissipation is 1.4 W at an ambient temperature of 70°C. Ensure proper heat sinking and thermal management to prevent overheating.
The device is rated for operation up to 150°C. However, ensure proper thermal management and derate the power dissipation accordingly to prevent overheating.
Check for proper supply voltage, decoupling, and PCB layout. Verify the output stage is properly biased, and the load is within the recommended range. Consult the application note and NXP support resources for further assistance.