The maximum operating temperature range for the BTA06-600CRG is -40°C to 150°C.
To ensure proper triggering, apply a gate current of at least 100 mA and a gate voltage of at least 2.5 V, and ensure the gate pulse width is at least 10 μs.
A recommended snubber circuit consists of a 100 nF capacitor and a 47 Ω resistor in series, connected between the anode and cathode.
Use a voltage clamp or a varistor to protect against overvoltage, and a fuse or a current limiter to protect against overcurrent.
A recommended gate drive circuit consists of a pulse transformer or an optocoupler, with a series resistor and a clamp diode to protect the gate.