The recommended operating temperature range for the BU724A is -40°C to 125°C, although it can withstand storage temperatures from -55°C to 150°C.
To ensure proper biasing, connect the VCC pin to a stable 5V power supply, and the VEE pin to a stable -5V power supply. Additionally, decouple the VCC and VEE pins with 100nF capacitors to reduce noise and oscillations.
The maximum allowable input voltage for the BU724A is ±15V, although it's recommended to keep the input voltage within ±10V for optimal performance and to prevent damage to the device.
To prevent electrostatic discharge (ESD) damage, handle the BU724A by the body or use an anti-static wrist strap. Ensure the workspace and equipment are ESD-protected, and use ESD-safe packaging and storage materials.
The typical propagation delay for the BU724A is around 10ns to 20ns, although this can vary depending on the specific application, temperature, and operating conditions.