The recommended power-on sequence is to apply VCC before applying any input signals to the device. This ensures that the internal bias circuitry is established before the PLL is enabled.
To ensure the PLL locks to the correct frequency, ensure that the input frequency is within the specified range, and the loop filter components are correctly selected. Also, ensure that the VCO range is set correctly and the PLL is not over-driven.
The CD4046BE can handle a maximum frequency deviation of ±3.5% of the center frequency. Exceeding this limit may cause the PLL to lose lock or malfunction.
To minimize jitter, ensure that the input signal is clean and free of noise, and the loop filter components are correctly selected. Also, consider using a low-jitter reference clock and minimizing the number of clock domain crossings.
Yes, the CD4046BE can be used as a frequency multiplier. However, the output frequency range is limited to 1/4 to 4 times the input frequency. Also, ensure that the VCO range is set correctly and the PLL is not over-driven.