The recommended operating voltage range for the CD4541BE is 4.5V to 15.5V.
To ensure proper power-on and power-off, the CD4541BE requires a monotonic power supply ramp-up and ramp-down. A minimum of 1ms is recommended for power-on and power-off times.
The maximum frequency of operation for the CD4541BE is 100 kHz.
The output stage of the CD4541BE is an open-drain configuration, which means it can sink current but not source current. An external pull-up resistor is required to pull the output high.
The R/C oscillator circuit in the CD4541BE is used to generate the internal clock signal. The oscillator frequency is determined by the values of the external resistor and capacitor connected to pins 1 and 2.