The recommended operating voltage range for CD54HCT164F3A is 4.5V to 5.5V, although it can operate down to 3V with reduced performance.
Unused inputs on the CD54HCT164F3A should be tied to VCC or GND to prevent floating inputs, which can cause excessive power consumption and noise.
The maximum clock frequency that the CD54HCT164F3A can handle is 30 MHz, although this can vary depending on the specific application and operating conditions.
Yes, the CD54HCT164F3A can be used in a 3.3V system, but the output voltage levels may not be fully compatible with 3.3V logic. A voltage translator or level shifter may be required.
To ensure proper power-on and power-off sequencing, the VCC pin should be powered on before the clock signal, and the clock signal should be disabled during power-off.