The recommended operating voltage range for CD54HCT573F3A is 4.5V to 5.5V.
To ensure signal integrity, use a low-impedance PCB design, keep signal traces short, and use termination resistors to minimize reflections.
While CD54HCT573F3A is specified for 5V operation, it can be used in a 3.3V system with some limitations. Consult the datasheet for specific guidelines.
The maximum clock frequency supported by CD54HCT573F3A is 100 MHz.
Power sequencing is critical to prevent latch-up. Ensure that VCC is applied before any input signals, and that all inputs are at a valid logic level before VCC is applied.