The maximum frequency of operation for the CD74AC573M96 is 100 MHz.
To ensure that the output is not corrupted during power-up or power-down, it is recommended to use a pull-up or pull-down resistor on the output pins to prevent unwanted voltage levels.
The recommended operating voltage range for the CD74AC573M96 is 2.0 V to 6.0 V.
The propagation delay of the CD74AC573M96 is typically around 10 ns. To handle this, ensure that the clock frequency is not too high, and consider using a clock signal with a 50% duty cycle to minimize the impact of propagation delay.
Yes, the CD74AC573M96 can be used in a 3.3 V system. However, ensure that the input voltage levels are compatible with the 3.3 V system, and consider using level translators if necessary.