The recommended operating voltage range for CD74ACT574M96 is 4.5V to 5.5V, although it can operate from 2V to 6V with reduced performance.
It is recommended to power up the VCC pin before the input signals, and power down the VCC pin after the input signals. This ensures that the device is properly initialized and avoids any potential latch-up or damage.
The maximum frequency of operation for CD74ACT574M96 is typically around 100 MHz, although this can vary depending on the specific application and operating conditions.
It is recommended to use a pull-up or pull-down resistor on the output signals to ensure proper termination and to prevent signal reflection or ringing. The value of the resistor depends on the specific application and operating conditions.
The maximum current that CD74ACT574M96 can sink or source is typically around 24 mA per output pin, although this can vary depending on the specific application and operating conditions.