The maximum frequency of operation for the CD74HC147PWR is 25 MHz.
To ensure proper power supply, connect VCC to a 2.0-V to 6.0-V power supply, and GND to the system ground. Decouple the power supply with a 0.1-μF capacitor.
The maximum input voltage that the CD74HC147PWR can tolerate is 6.5V, which is the absolute maximum rating.
Unused inputs should be tied to VCC or GND through a 1-kΩ resistor to prevent floating inputs and reduce power consumption.
The propagation delay of the CD74HC147PWR is typically 10 ns, but it can vary depending on the operating conditions and load capacitance.