The maximum operating frequency of the CY14B256Q2A-SXI is 108 MHz.
To implement a hardware reset, assert the RESET# pin low for a minimum of 10 ns. This will reset the device and return it to its default state.
The VCAP pin is used to connect a capacitor to store the voltage that powers the internal voltage regulator. This capacitor should be a 10 μF ceramic capacitor with a 10% tolerance.
Yes, the CY14B256Q2A-SXI is compatible with 3.3V systems. The device operates from a single 3.0V to 3.6V power supply.
To perform a page write, send a write command (0x02) followed by the address and data. The device will automatically handle the page write operation.