The CY14MB064Q2B-SXI has an operating temperature range of -40°C to +85°C.
It is recommended to power up VCC before VCCQ, and power down VCCQ before VCC to prevent latch-up and ensure proper operation.
The recommended clock frequency for the CY14MB064Q2B-SXI is up to 104 MHz, but it can operate at frequencies up to 108 MHz with reduced performance.
A reset circuit can be implemented using a resistor-capacitor (RC) network connected to the RESET pin, with a recommended value of 1 kΩ for the resistor and 10 nF for the capacitor.
The maximum current consumption of the CY14MB064Q2B-SXI is 35 mA at 104 MHz, and 45 mA at 108 MHz.