The recommended power-up sequence is to apply VCC first, followed by VDD, and then the clock signal. This ensures proper initialization and prevents latch-up.
Use a clock buffer or a clock domain crossing circuit to ensure proper clock signal transmission and synchronization between different clock domains.
The CY22394FXC can drive up to 30 pF of capacitive load. Exceeding this limit may affect signal integrity and reliability.
The CY22394FXC is designed to operate with a 3.3V supply voltage. Using a different voltage supply may affect the device's performance, power consumption, and reliability. Consult Cypress Semiconductor for specific guidance.
Use a reset circuit that meets the device's reset timing requirements. A simple RC circuit with a 10 kΩ resistor and a 10 nF capacitor can be used. Consult the datasheet for specific reset timing requirements.