The CY62138FV30LL-45ZXIT can operate from -40°C to 85°C, making it suitable for industrial and commercial applications.
It's recommended to power up the VCC supply before the VSS supply, and power down the VSS supply before the VCC supply to prevent latch-up. Also, ensure that the power supply ramps up and down slowly to prevent voltage spikes.
The maximum clock frequency for the CY62138FV30LL-45ZXIT is 45 MHz, but it can be operated at lower frequencies as well.
The CY62138FV30LL-45ZXIT has a built-in power-down feature that retains data as long as the VCC supply is above 2V. However, it's recommended to use an external power-down detector or supervisor circuit to ensure data integrity during power-down or brownout conditions.
Yes, the CY62138FV30LL-45ZXIT is compatible with 3.3V systems, but ensure that the input signals are within the recommended voltage range of 2.2V to 3.6V.