The recommended power-up sequence is to apply VDD first, followed by VREF, and then the digital inputs. This ensures proper device operation and prevents potential latch-up conditions.
-
To ensure accurate voltage output, it's essential to use a low-noise, low-impedance voltage reference (VREF) and to decouple the VREF pin with a capacitor. Additionally, ensure that the output load is within the specified range, and the output voltage is not loaded beyond the maximum capacitive load.
-
The maximum clock frequency for the DAC104S085 is 40 MHz. However, the actual clock frequency may be limited by the specific application and the quality of the clock signal.
-
To enter power-down mode, assert the PD pin low. In this mode, the DAC output is disconnected from the output pin, and the device consumes minimal power. When exiting power-down mode, ensure that the PD pin is de-asserted before applying a new input code to prevent output glitches.
-
The DAC104S085's performance is affected by temperature, with the output voltage and linearity varying with temperature. The device is specified to operate over a temperature range of -40°C to 125°C, and the user should consider these variations when designing their application.