A thermal pad is recommended under the package to improve heat dissipation. A minimum of 2oz copper thickness and a thermal relief pattern are recommended for optimal thermal performance.
Ensure that the device is operated within the recommended operating temperature range (-40°C to 125°C). Use a heat sink or thermal interface material to improve heat dissipation, and avoid exceeding the maximum junction temperature (Tj) of 150°C.
A 10uF to 22uF X5R or X7R ceramic capacitor is recommended for input decoupling, placed as close to the device as possible. The capacitor should be rated for the input voltage and have a low ESR.
Use a TVS diode or a zener diode to protect the device from overvoltage. Add a fuse or a PTC resettable fuse to protect against overcurrent. Ensure that the device is operated within the recommended operating conditions.
A 10uF to 22uF X5R or X7R ceramic capacitor is recommended for output filtering, placed as close to the device as possible. The capacitor should be rated for the output voltage and have a low ESR.