The recommended operating voltage range for the DG441CY+T is 4.5V to 30V, although it can operate up to 36V with reduced performance.
To ensure correct switching with a low-voltage logic signal, use a voltage translator or level shifter to translate the logic signal to the supply voltage of the DG441CY+T.
The maximum current rating for the DG441CY+T is 30mA per channel, although this can be limited by the power dissipation of the device.
To minimize power consumption, use the lowest possible supply voltage, reduce the switching frequency, and use a low-impedance load.
Yes, the DG441CY+T can be used as a multiplexer or demultiplexer by connecting the channels in a specific configuration and controlling the switches accordingly.