The recommended torque for the screw terminals is 0.5 Nm to 1.5 Nm. It's essential to follow this torque specification to ensure reliable connections and prevent damage to the terminals.
Yes, the DRB12-102PAE-L018 is designed to withstand vibrations up to 10G (according to IEC 60068-2-6) and can be used in high-vibration environments. However, it's essential to ensure proper mounting and secure the relay to prevent damage or dislodging.
The maximum switching frequency for the DRB12-102PAE-L018 is 30 operations per minute. Exceeding this frequency may lead to premature wear and reduced relay lifespan.
The DRB12-102PAE-L018 is not designed for use in hazardous locations. It does not meet the requirements for explosion-proof or intrinsically safe applications. If you need a relay for hazardous locations, consider a different model or consult with TE Connectivity for a suitable alternative.
The DRB12-102PAE-L018 is designed to operate within a temperature range of -40°C to 85°C. While it can tolerate high temperatures, it's essential to ensure proper cooling and avoid exceeding the maximum operating temperature to prevent damage or malfunction.