A good PCB layout for the DRV592VFP should have a solid ground plane, separate analog and digital grounds, and keep the high-current paths short and wide. TI provides a recommended layout in the datasheet and application notes.
Choose an inductor with a high saturation current, low DC resistance, and a suitable inductance value. TI recommends an inductor with a value between 1.5uH to 3.3uH. The datasheet provides a list of recommended inductors.
The maximum input voltage for the DRV592VFP is 18V. However, the recommended operating voltage range is 6V to 15V. Exceeding the maximum input voltage can damage the device.
Use a voltage supervisor or a power-on reset circuit to monitor the input voltage and reset the device if it exceeds the recommended operating range. You can also use a voltage regulator to regulate the input voltage.
The maximum output current of the DRV592VFP is 2A. However, the recommended operating current is up to 1.5A. Exceeding the maximum output current can damage the device.